Abstract: | Conventional types of municipal incinerators generate enormous quantities of stack gas because of high excess air and high temperatures. Under these conditions the size and cost of equipment to clean the flue gas to low dust contents are large. By burning the refuse in boiler furnaces at low excess air, and generating steam, the volume of flue gas to be cleaned is reduced to a minimum. Where high efficiency of flue-dust collection is required, steam generation from refuse firing permits a major saving on the cost of dust collection. |