A 10 μm Outpoint Size Selective Inlet for Hi-Vol Samplers
Authors:Andrew R McFarland  Carlos A Ortiz  Russell W Bertch Jr
Institution:1. Air Quality Laboratory Texas , A&2. M University , College Station , Texas , USA
Abstract:A Two-stage Size Selective Inlet for use with hi-vol samplers was designed and tested. The inlet, which operates at a flow rate of 1.13 m3/min, is shown to have a cutpoint of 9.8 μm and a fractionation curve slope of 1.45. The cutpoint is well within the EPA suggested limits of 10 ± 1 μm. Fractionation is not affected by wind speed over the test range of 2-24 km/h.

Re-entrainment or bounce of solid particles is not of consequence. The difference in penetration of 20 μm aerodynamic diameter glass beads and liquid aerosols is less than 1% at all wind speeds.