首页 | 本学科首页   官方微博 | 高级检索  
     

待生滑阀异常关闭导致催化裂化装置停车事故分析
引用本文:龚红霞,李新杰,张俊. 待生滑阀异常关闭导致催化裂化装置停车事故分析[J]. 安全.健康和环境, 2014, 0(5): 4-5
作者姓名:龚红霞  李新杰  张俊
作者单位:中国石化河南油田分公司南阳石蜡精细化工厂;
摘    要:针对催化裂化装置待生滑阀突然关闭导致装置停车事故,通过对仪表及系统处理过程进行原因分析,总结了事故的经验教训及防范措施,指出了炼化企业大型设备不但要正确使用,更要精心维护保养,才能确保装置正常平稳运行防患于未然。

关 键 词:催化裂化装置  待生滑阀  停车事故  事故分析

Accident Analysis on Shutdown of CCU due to the Abnormal Shutdown of Spent Slide Valve
Gong Hongxia,Li Xinjie,Zhang Jun. Accident Analysis on Shutdown of CCU due to the Abnormal Shutdown of Spent Slide Valve[J]. Safety Environment Health, 2014, 0(5): 4-5
Authors:Gong Hongxia  Li Xinjie  Zhang Jun
Affiliation:(SINOPEC Henan Oilfield Nanyang Paraffin Fine Chemical Plant, Henan, Nanyang, 473132)
Abstract:In allusion to the shutdown of unit resulted by the sudden shutdown of CCU spent slide valve,through reason analysis on instrument and system processing process,the lessons from the accident and preventive measures are summed up.It also points out that the large scale equipments in the refinery enterprise should be not only be used correctly but also maintained carefully,so that the unit can run normally and stably to prevent from hidden dangers.
Keywords:CCU  spent slide valve  parking accident  accident analysis