Abstract: | The determination of the total flow of an alluvial stream by rating a gaging station with a current meter may not be sufficiently accurate for a water yield study. If a large part of the total water yield consists of low flow, a means for accurate measurement must be employed. A technique for the design of a low flow control is described in this paper. Eight low flow controls have been designed on streams of the Southern Plains Watershed Research Center, Chickasha, Oklahoma. Field calibration measurements from these installations have been used to verify the design technique. |