Effect of operational parameters on heavy metal removal by electrocoagulation
Authors:D Bhagawan  Saritha Poodari  Tulasiram Pothuraju  D Srinivasulu  G Shankaraiah  M Yamuna Rani  V Himabindu  S Vidyavathi
Institution:1. Center for Environment, Institute of Science and Technology, Jawaharlal Nehru Technological University, Hyderabad, Kukatpally, 500085, India
2. Department of Civil Engineering, College of Engineering, Jawaharlal Nehru Technological University, Hyderabad, 500085, India
Abstract:In the present paper, the performance of electrocoagulation (EC) for the treatability of mixed metals (chromium (Cr), copper (Cu), lead (Pb), nickel (Ni), and zinc (Zn)) from metal plating industrial wastewater (EPW) has been investigated. The study mainly focused on the affecting parameters of EC process, such as electrode material, initial pH, distance between electrodes, electrode size, and applied voltage. The pH 8 is observed to be the best for metal removal. Fe–Fe electrode pair with 1-cm inter-electrode distance and electrode surface area of 40 cm2 at an applied voltage of 8 V is observed to more efficient in the metal removal. Experiments have shown that the maximum removal percentage of the metals like Cr, Ni, Zn, Cu, and Pb are reported to be 96.2, 96.4, 99.9, 98, and 99.5 %, respectively, at a reaction time of 30 min. Under optimum conditions, the energy consumption is observed to be 51.40 kWh/m3. The method is observed to be very effective in the removal of metals from electroplating effluent.
Keywords:
本文献已被 SpringerLink 等数据库收录!