Time-resolved measurements of aerosol elemental concentrations in indoor working environments
Authors:M. Žitnik  A. Kastelic  Z. Rupnik  P. Pelicon  P. Vaupetič  K. Bučar  S. Novak  Z. Samardžija  S. Matsuyama  G. Catella  K. Ishii
Affiliation:1. Jo?ef Stefan Institute, P.O. Box 3000, SI-1001 Ljubljana, Slovenia;2. Department of Quantum Science and Energy Engineering, Tohoku University, Aramaki-Aza-Aoba 6-6-01-2, Aoba-ku, Sendai 980-8579, Japan;1. Office of Environmental Health & Safety, Public Health Services Brabant/Zeeland, P.O. Box 3166, 5203 DD ''s-Hertogenbosch, The Netherlands;2. Department of Environmental Science, Institute for Water and Wetland Research, Radboud University Nijmegen, P.O. Box 9010, 6500 GL Nijmegen, The Netherlands;3. National Institute for Public Health and The Environment (RIVM), P.O. Box 1, 3720 BA Bilthoven, The Netherlands;1. Department of Mechanical and Aerospace Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6, Canada;2. Department of Mechanical Engineering, Dokuz Eylul University, Buca, Izmir 35397, Turkey;1. ICP Institute of Computational Physics, ZHAW Zurich University of Applied Sciences, Technikumstrasse 9, CH-8401 Winterthur, Switzerland;2. Nonmetallic Inorganic Materials, Department of Materials, ETH Zurich, Wolfgang-Pauli-Strasse 10, CH-8093 Zurich, Switzerland;1. Division of Cardiology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea;2. Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea;3. Cardiovascular Imaging Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea;4. Department of Internal Medicine, Cardiovascular Center, Seoul National University Hospital, Seoul, Korea;5. Division of Cardiovascular Diseases, Mayo Clinic College of Medicine, Rochester, Minnesota;1. University of Wisconsin-Madison, Environmental Chemistry and Technology Program, Madison, WI 53706, USA;2. Wisconsin State Laboratory of Hygiene, Madison, WI 53718, USA
Abstract:We have measured the elemental concentrations in aerosols with a 2-h time resolution in two different types of working environment: a chemistry laboratory dealing with the processing of advanced nanoparticulate materials and a medium-sized machine workshop. Non-stop 10-day and 12-day samplings were performed at each location in order to determine the concentration trends during the non-working/working and weekday/weekend periods. Supplementary measurements of PM10 aerosols with a 2-day sample collection time were performed with a standard Gent PM10 sampler to compare the elemental concentrations with the time-averaged concentrations detected by the 2D step-sampler. The concentrations were determined a posteriori by analyzing the x-ray spectra of aerosol samples emitted after 3-MeV proton bombardment. The PM10 samples collected in the chemistry laboratory were additionally inspected by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) to determine the chemical compositions of the individual particles. In the workshop, a total PM10 mass sampling was performed simultaneously with a minute resolution to compare the signal with typical outdoor PM10 concentration levels. A factor analysis of the time-resolved dataset points to six and eight factors in the chemistry laboratory and the machine workshop, respectively. These factors describe most of the data variance, and their composition in terms of different elements can be related to specific indoor activities and conditions. We were able to demonstrate that the elemental concentration sampling with hourly resolution is an excellent tool for studying the indoor air pollution. While sampling the total PM10 mass concentration with a minute resolution may lack the potential to identify the emission sources in a “noisy” environment, the time averaging on a day time scale is too coarse to cope with the working dynamics, even if elemental sensitivity is an option.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号