固相萃取-气相色谱-质谱-选择离子法检测污水中壬基酚
引用本文:郝瑞霞,梁鹏,赵曼,王俊安,周玉文.固相萃取-气相色谱-质谱-选择离子法检测污水中壬基酚[J].环境科学,2006,27(11):2222-2227.
作者姓名:郝瑞霞  梁鹏  赵曼  王俊安  周玉文
作者单位:北京工业大学建筑工程学院,北京,100022
基金项目:北京市自然科学基金项目(8042005)
摘    要:壬基酚是城市污水和再生水中的1种痕量污染物,具有内分泌干扰作用.由于壬基分支程度的不同,有多种同分异构体存在,基体背景复杂,定量检测困难.采用固相萃取-气相色谱-质谱和选择性离子定量分析方法,对70多个污水和再生水样品中壬基酚同分异构体总量进行了定量检测.结果表明,亲水-亲脂平衡固相萃取柱对壬基酚有良好选择吸附能力,不同水样的浓缩倍数在50~200倍之间.在壬基酚各异构体质谱图中,107、121、135、149、163这5种离子的丰度较高,特异性较强,其响应值总和(∑SIM)占总离子流(TIC)的54.4%~73%,以∑SIM(107、121、135、149、163)色谱图的积分面积作为定量检测的依据,既准确地反映各种异构体的组成,又排除了背景离子的干扰,确保了方法的选择性、准确度和精密度.

关 键 词:壬基酚  内分泌干扰作用  污水  固相萃取-气相色谱-质谱-选择离子  定量检测
文章编号:0250-3300(2006)11-2222-06
收稿时间:2005-11-28
修稿时间:2005-11-282006-01-11

Determination of Nonylphenol in Wastewater by Solid Phase Extraction Gas Chromatography Mass Spectrometry and Multi-Selective Ions
Hao Rui-Xia,Liang Peng,Zhao Man,Wang Jun-An,Zhou Yu-Wen.Determination of Nonylphenol in Wastewater by Solid Phase Extraction Gas Chromatography Mass Spectrometry and Multi-Selective Ions[J].Chinese Journal of Environmental Science,2006,27(11):2222-2227.
Authors:Hao Rui-Xia  Liang Peng  Zhao Man  Wang Jun-An  Zhou Yu-Wen
Institution:The College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100022, China
Abstract:Nonylphenol (NP) having endocrine disrupter activity is an ultra trace component in sewage and reuse wastewater. There are many NP isomers in the wastewater because nonyl structure is different. The background impurity of the samples is very complex with many other components. So it is difficulty for quantitative analysis of NP in the samples. About seventy sewages and recycled wastewater samples were measured for the content of NP isomer mixtures by solid-phase extraction-gas chromatography-mass spectrometry and multi-selected ions monitoring (shortened as SPE-GC-MS-SIM). The results show that hydrophilic-lipophilic-equilibrium solid-phase extraction pole has selective adsorption for NP, so that the samples can be concentrated from 50 to 200 times. The five kinds of mass spectrum ions, i. e. 107, 121, 135, 149, 163, have higher abundance and distinct character. The sum of five selected ion monitoring (sigmaSIM) is from 54.4 to 73 percent of the total ion current for NP, which can accurately represent different NP isomers. Quantitative analysis base on the spectral integralof the sigmaSIM chromatograph can eliminate interference with background signal and ensure selectivity, accuracy and precision ofthe method.