Dynamic model for a heat exchanger tube rupture discharging a high-pressure flashing liquid into a low-pressure liquid-filled shell |
| |
Authors: | C.J. EnnisK.K. Botros C. Patel |
| |
Affiliation: | NOVA Chemicals Corporation, 2928 - 16 Street N.E., Calgary, Alberta, Canada T2E 7K7 |
| |
Abstract: | Shell-tube type heat exchangers are often used to exchange heat between a high-pressure fluid and a low-pressure fluid. The pressure difference between these two fluids could be significantly high. In the event of a partial or full rupture of a tube, a problem may arise in that a transient pressure rise phenomenon could occur due to the flashing of the high-pressure sub-cooled fluid in the tube into the low-pressure shell, which may cause the shell to rupture with subsequent damage to equipment. This paper presents a dynamic model to describe the transient phenomenon occurring on the shell side following various scenarios of tube rupture. The spatial and temporal aspects of the flow transients along the pressure safety valve riser are accounted for by solving the one-dimensional continuity and momentum hyperbolic partial differential equations as applied to the liquid-filled riser. The dynamics of the attached piping system are also accounted for via two mechanistic models; the first is based on an inertial-resistive assumption of the fluids in this system, while the other is based on the assumption of anechoic perturbations passing through a long section of the attached piping. The latter is justified in cases where the attached piping is long enough such that reflections from the downstream end do not interfere with transients occurring in the shell during the initial phase of fluid flashing into the shell side following rupture. The various phases of this phenomenon are described, however the paper focuses on the initial phase of the phenomenon during which shell overpressure may be encountered. The model is applied to two ethylene heaters in tandem; the first uses propylene on the shell side to heat the ethylene on the tube side, while the second uses methanol, also on the shell side. The ratio between the shell design pressure to the tube design pressure in these two heaters are 0.169 and 0.154, respectively, hence the motivation to accurately model the transients involved in this phenomenon. The practical aspects and discussion around techniques to alleviate potential overpressure scenarios due to tube rupture are emphasized throughout the paper. |
| |
Keywords: | Heat exchangers Tube rupture API 520 Pressure safety valve Flashing liquids Risk |
本文献已被 ScienceDirect 等数据库收录! |
|