首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Comparative study of non-invasive methods for assessing Daphnia magna embryo toxicity
Authors:Matthew C Stensberg  Michael Anthony Zeitchek  Kul Inn  Eric S McLamore  D Marshall Porterfield  Maria S Sepúlveda
Institution:1. Department of Agriculture and Biological Engineering, Purdue University, West Lafayette, IN, USA
2. Birck-Bindley Physiological Sensing Facility, Purdue University, West Lafayette, IN, USA
3. Agricultural and Biological Engineering Department, University of Florida, Gainesville, FL, USA
4. Department of Forestry and Natural Resources, Purdue University, West Lafayette, IN, USA
Abstract:Embryos, unlike adults, are typically sessile, which allows for an increase in the available metrics that can be used to assess chemical toxicity. We investigate Daphnia magna development rate and oxygen consumption as toxicity metrics and compare them to arrested embryo development using four different techniques with potassium cyanide (KCN) as a common toxicant. The EC50 (95 % CI) for arrested development was 2,535 (1,747–3,677) μg/L KCN. Using pixel intensity changes, recorded with difference imaging, we semi-quantitatively assessed a decrease in development rate at 200 μg/L KCN, threefold lower than the arrested development lowest observed effect concentration (LOEC). Respirometry and self-referencing (SR) microsensors were two unique techniques used to assess oxygen consumption. Using respirometry, an increase in oxygen consumption was found in the 5 μg/L KCN treatment and a decrease for 148 μg/L, but no change was found for the 78 μg/L KCN treatment. Whereas, with SR microsensors, we were able to detect significant changes in oxygen consumption for all three treatments: 5, 78, and 148 μg/L KCN. While SR offered the highest sensitivity, the respirometry platform developed for this study was much easier to use to measure the same endpoint. Oxygen consumption may be subject to change during the development process, meaning consumption assessment techniques may only be useful only for short-term experiments. Development rate was a more sensitive endpoint though was only reliable four of the six embryonic developmental stages examined. Despite being the least sensitive endpoint, arrested embryo development was the only technique capable of assessing the embryos throughout all developmental stages. In conclusion, each metric has advantages and limitations, but because all are non-invasive, it is possible to use any combination of the three.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号