首页 | 本学科首页   官方微博 | 高级检索  
     检索      

生物接触氧化预处理微污染源水中BOD 5的测定
引用本文:李秀虹.生物接触氧化预处理微污染源水中BOD 5的测定[J].环境监测管理与技术,2006,18(3):39-40.
作者姓名:李秀虹
作者单位:广东粤港供水有限公司,广东,深圳,518021
摘    要:在微污染源水生物预处理中,由于生物池内和处理后的出水中含有大量硝化细菌,使BOD5测定结果偏大.提出在测定这类水样时,加入硝化细菌抑制剂,可以消除硝化作用的影响.

关 键 词:微污染源水  BOD5  硝化细菌  硝化抑制剂
文章编号:1006-2009(2006)03-0039-02
收稿时间:2005-02-04
修稿时间:2006-02-23

M ensurate BOD 5 ofPretreatmentW astewater by Aquatic Catalytic Oxidation in PollutionM icro-source
LI Xiu-hong.M ensurate BOD 5 ofPretreatmentW astewater by Aquatic Catalytic Oxidation in PollutionM icro-source[J].The Administration and Technique of Environmental Monitoring,2006,18(3):39-40.
Authors:LI Xiu-hong
Institution:Guangdong Yuegang Water-supply Limited Company, Shenzhen, Guangdong 518021, China
Abstract:The result of BOD5 of the wastewater is high than the normal after aquatic pretreatment in pollution micro-source of, because there is lot of nitrifying bacteria in the biological pond and wastewater. For solving it, this article thought the nitrifying bacteria inhibitor should be joined before determines this kind of water in order to eliminate the influence of nitrification.
Keywords:Wastewater from micro-source  BOD5  Nitrifying bacteria  Nitrification inhibitor
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《环境监测管理与技术》浏览原始摘要信息
点击此处可从《环境监测管理与技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏