Flow Field and Pollution Dispersion in a Central London Street
Authors:CM N' Riain  B Fisher  C J Martin  J Littler
Institution:1. Research in Building Group, Department of Architecture and Engineering, University of Westminster, 35 Marylebone Road, LONDON, NW1 5LS
2. Department of Environmental Sciences, University of Greenwich, Rachel MacMillan Building, Creek Road, Deptford, LONDON, SE8 3BW
3. Energy Monitoring Company Ltd., 3 Chapel Court, Newport Pagnell, Bucks., MK16 0EW, ???
Abstract:Urban pollution due to roadways is perceived as a major obstacle to implementing low-energy ventilation design strategies in urban non-domestic buildings. As part of a project to evaluate the use of a computational fluid flow model as an environmental design tool for urban buildings, this paper seeks to address the impact of pollution from roadways on buildings in areas of restricted topography and assess dominant influencing factors and other requirements for testing the flow model predictions. Vertical profiles of carbon monoxide (CO) and temperature at the facade of a building in a Central London street, in addition to above-roof wind speed and direction, were measured over a period of three months. The street has a height-to-width (h/W) ratio of 0.6 and is of asymmetric horizontal alignment. The air flows in the area surrounding the building were modelled using a computational fluid flow model for two orthogonal wind directions. CO concentrations were calculated from the steady-state flow field in order to place point measurements in the context of the flow field, identify persistent features in the measured data attributable to the flow structure and, by comparison with measurements, identify further testing requirements.Some qualitative and quantitative agreement between measured and modelled data was obtained. Measured CO levels at the building facade and vertical variations of CO were small, as predicted by the model. A wake-interference type flow was predicted by the model for wind speeds >2ms-1 with formation of a vortex cell occurring for roof-level wind speeds >5ms-1 for the cross-wind direction, which was reflected in the measured CO levels and facade gradients. A direction-dependent inverse relationship was noted, both in the model and measurements, between above-roof wind speed and facade CO levels although statistical correlations in the time series were poor. CO concentrations at the facade were found to increase with height frequently, as well as decrease, especially for parallel winds. It is expected that mechanical turbulence due to vehicles was largely responsible. In comparison, thermal stratification appeared to play only a minor role in controlling vertical mixing in the street, under low wind speed conditions.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号