首页 | 本学科首页   官方微博 | 高级检索  
     


Indoor and outdoor formaldehyde concentrations in homes in residential areas in Greater Cairo
Authors:Khoder M I  Shakour A A  Farag S A  Abdel Hameed A A
Affiliation:Air Pollution Department, National Research Centre, Dokki, Giza, Cairo, Egypt.
Abstract:Indoor and outdoor measurements of formaldehyde were conducted at seven flats located in residential areas in Greater Cairo, during spring and summer seasons 1999. The mean daytime formaldehyde concentrations in kitchens, bedrooms and living rooms were 89, 100 and 100 ppb, respectively, in the seven flats. Significant positive correlations were found between the concentrations of formaldehyde found in these three rooms. On the other hand, no significant differences were found between the mean formaldehyde concentrations in these three rooms. The maximum mean concentration of formaldehyde (147 ppb) was recorded in a new flat, while the minimum concentration (43 ppb) was observed in an old flat. The maximum hourly and daytime concentrations were 350 and 225 ppb, respectively. Air temperature, relative humidity and the age of the flat are factors affecting the emission and concentration of formaldehyde. The maximum indoor and outdoor formaldehyde concentrations were recorded during the summer season. During the spring, 38% of the samples indicated that the concentration of formaldehyde in the seven flats exceeded 0.1 ppm, the American Society of Heating, Refrigerating, and Air Conditioning Engineers' (ASHRAE) standard; in the summer, this figure increased to 53%.
Keywords:
本文献已被 PubMed 等数据库收录!