首页 | 本学科首页   官方微博 | 高级检索  
     检索      

混酸消解玻璃纤维滤筒滤膜法测定大气颗粒物中的铅
引用本文:孙靖,张长寿.混酸消解玻璃纤维滤筒滤膜法测定大气颗粒物中的铅[J].环境科学导刊,2013(4):117-119.
作者姓名:孙靖  张长寿
作者单位:江阴秋毫检测有限公司,江苏江阴214400
摘    要:用高氯酸、硝酸和氢氟酸组成的混酸在加热的条件下消解玻璃纤维滤筒滤膜采集的铅尘样品,可基本除去滤膜中的硅。大部分除去滤筒中的硅,残留的硅酸对铅的溶出和准确测定不干扰。因此是取代索氏提取法和酸煮法的理想方法。

关 键 词:铅尘  测定  玻璃纤维滤筒滤膜  混酸

Measurement of the Particle in Air with Mixed Acid Plus Fiberglass Filter
SUN Jing,ZHANG Chang-shou.Measurement of the Particle in Air with Mixed Acid Plus Fiberglass Filter[J].Yunnan Environmental Science,2013(4):117-119.
Authors:SUN Jing  ZHANG Chang-shou
Institution:(Jiangyin Qiuhao Testing Limited Company, Jiangyin Jiangsu 214400 China)
Abstract:The air dust collected by glass fiber filter is dissolved with mixture of perchloric acid, nitric acid and hydrofluoric acid, and most silicon in the filter could be removed. The remained silieic acid will not influence the dissolubility of the lead and the accuracy of measurement. It is an ideal method to replace the methods of Soxhlet extraction and acid decoction.