LEEMAN测汞仪测定痕量(ppt级)Hg
引用本文:杨春艳. LEEMAN测汞仪测定痕量(ppt级)Hg[J]. 云南环境科学, 2006, 25(4): 58-60
作者姓名:杨春艳
作者单位:云南省环境监测中心,云南昆明650034
摘    要:天然水体中含汞极少,一般需经过浓缩富集后进行分析测试。利用LEEMAN测汞仪在实验室条件及实验用试剂达到要求,在不富集的情况下检测限≤15ppt,能满足地表水环境质量标准限值Ⅰ类、Ⅱ类水及Ⅰ类、Ⅱ类地下水中汞的测定。

关 键 词:LEEMAN测汞仪  痕量汞  测定
文章编号:1006-947X(2006)04-0058-03
收稿时间:2005-06-29
修稿时间:2005-06-29

Trace Mercury Monitoring by LEEMAN Mercury Vapormeter
YANG Chun-yan. Trace Mercury Monitoring by LEEMAN Mercury Vapormeter[J]. Yunnan Environmental Science, 2006, 25(4): 58-60
Authors:YANG Chun-yan
Abstract:The content of mercury in natural water body is less, which is monitored by concentration. LEEMAN mercury vapormeter under lab condition without thickening the mercury can monitor the content of mercury, the test limit is less than 15ppt, which can meet the requirements of environmental quality standard.
Keywords:LEEMAN mercury vapormeter   trace mercury   monitor