Turbulent deflagrations of mildly flammable refrigerant-air mixtures
Institution:1. Guangdong Provincial Key Laboratory of Fire Science and Technology, Guangzhou, China;2. School of Engineering, Sun Yat-Sen University, Guangzhou 510006, China;3. State Key Laboratory of Biocontrol, Guangdong Provincial Key Laboratory for Aquatic Economic Animals and Guangdong Provincial Engineering Technology Research Center for Healthy Breeding of Important Economic Fish, School of Life Sciences, Sun Yat-Sen University, Guangzhou 510275, China;1. Department of Mechanical Engineering, Tokyo University of Science, Suwa 5000-1 Toyohira, Chino, Nagano 391-0292, Japan;2. Department of Mechanical Systems Engineering, Tokyo University of Science, Suwa 5000-1 Toyohira, Chino, Nagano 391-0292, Japan;1. Jiangsu Key Laboratory of Hazardous Chemicals Safety and Control, Nanjing, 210009, China;2. College of Safety Science and Engineering, Nanjing Tech University, Nanjing, 210009, China;3. Jiangsu Laboratory of Advanced Functional Material, Department of Chemistry and Material Engineering, Changshu Institute of Technology, Changshu, 215500, China;1. Physikalisch-Technische Bundesanstalt, Braunschweig, Germany;2. Technische Universitaet Braunschweig, Institute for High Voltage Technology and Electrical Power Systems – elenia, Braunschweig, Germany;1. Pittsburgh Mining Research Division, National Institute for Occupational Safety and Health, United States;2. NIOSH, United States
Abstract:With current concerns around global climate change, new hydrofluorocarbons with low Global Warming Potential (GWP) are being evaluated as alternative refrigerants. These alternative refrigerants, however, may be mildly flammable (as defined by the A2L safety group classification) and pose safety concerns for the heating, ventilation, air conditioning, and refrigeration (HVAC/R) industry. Consequently, careful assessments of different flammability characteristics and risks for these refrigerants are essential for their safe use in actual applications. In this study, deflagration propagation measurements for different mildly flammable refrigerants, including difluoromethane (R-32) and 2,3,3,3-tetrafluoropropene (R-1234yf), were undertaken in different geometries including a 9.1-m long conduit test rig and a closed cubical 12.5 m3 volume. Different tests were conducted for full volume deflagrations as well as with and without obstructions. Turbulent deflagration speeds for well-mixed, refrigerant-air mixtures have been shown to be orders of magnitude larger than their corresponding laminar flame speed values that are used in classifying flammable refrigerants in safety standards. Testing has also quantified the resulting severity as measured by the event overpressure which was shown to worsen with increased congestion or confinement as a consequence of increased induced turbulence. This work illustrates the importance for severity evaluations for actual large-scale or congested geometries of concern in practical applications. Even for mildly flammable refrigerants characterized by laminar flame speeds <2 cm/s, which is lower than the 10 cm/s limit for A2L refrigerants, relatively fast deflagrations can be generated for very congested geometries where downstream turbulence is generated as the flame front passes over obstacles in these situations.
Keywords:Flammable refrigerants  Premixed flames  Deflagration  Overpressure
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号