A constant-volume rapid exhaust dilution system for motor vehicle particulate matter number and mass measurements |
| |
Authors: | Maricq M Matti Chase Richard E Xu Ning Podsiadlik Diane H |
| |
Affiliation: | Scientific Research Laboratory, Ford Motor Co., Dearborn, Michigan 48121, USA. mmaricq@ford.com |
| |
Abstract: | An improved version of the constant volume sampling (CVS) methodology that overcomes a number of obstacles that exist with the current CVS dilution tunnel system used in most diesel and gasoline vehicle emissions test facilities is presented. The key feature of the new sampling system is the introduction of dilution air immediately at the vehicle tailpipe. In the present implementation, this is done concentrically through a cylindrical air filter. Elimination of the transfer hose conventionally used to connect the tailpipe to the dilution tunnel significantly reduces the hydrocarbon and particulate matter (PM) storage release artifacts that can lead to wildly incorrect particle number counts and to erroneous filter-collected PM mass. It provides accurate representations of particle size distributions for diesel vehicles by avoiding the particle coagulation that occurs in the transfer hose. Furthermore, it removes the variable delay time that otherwise exists between the time that emissions exit the tailpipe and when they are detected in the dilution tunnel. The performance of the improved CVS system is examined with respect to diesel, gasoline, and compressed natural gas vehicles. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|