首页 | 本学科首页   官方微博 | 高级检索  
     


LEAKY ACRES RECHARGE FACILITY: A TEN-YEAR EVALUATION1
Authors:H. I. Nightingale  J. E. Ayars  R. L. McCormick  D. C. Cehrs
Abstract:From 1971-1980, studies were conducted at Fresno, California, to identify and quantify, where possible, the soil and water chemistry, subsurface geologic, hydrologic, biologic, and operational factors that determine the long term (10-year) effectiveness of basin type artificial ground water recharge through alluvial soils. This paper updates previous findings and refers to publications that describe the geology beneath the basins and regional geology that determine the transmission and storage properties for local ground water management and chemical quality enhancement. High quality irrigation water from the Kings River was used for recharge. Construction and land costs for the present expanded facility 83 ha (205.2 ac) using three parcels of land were $1,457,100. The nine-year annual mean costs for only canal water, maintenance, and operation were $110.42/ha·m ($13.62/ac·ft) based on an average recharge rate of 1338 ha·m/yr (10,848 ac·ft/yr) at 86 percent facility efficiency. The measured end of season recharge rate averaged 14.97 ± 0.24 cm/day. The 10-year mean actual recharge rate based on actual water delivered, total ponded area, and total days of recharge was 12.1 cm/day.
Keywords:artificial ground water recharge  recharge water quantity and quality  recharge facility construction and economics  alluvial geology.)