首页 | 本学科首页   官方微博 | 高级检索  
     检索      

稠油采出水处理中试
引用本文:王飞.稠油采出水处理中试[J].化工环保,2016,36(4):439-442.
作者姓名:王飞
作者单位:中国石油 大庆油田水务公司,黑龙江 大庆 163000
摘    要:以活性焦为吸附剂,采用预吸附—水解酸化—曝气生物固定床滤池—后吸附组合工艺中试处理稠油采出水。试验结果表明,当预吸附进水COD为408.6~526.7 mg/L、预吸附池活性焦泥回流量为25%(w)、水解酸化池上升流速为0.22 m/h、曝气生物固定床滤池气水体积比为10∶1、后吸附池投加新活性焦2 kg时,组合工艺对稠油采出水COD的去除率达到90.0%,出水COD均值为46.2 mg/L,出水水质满足DB 21/1627—2008《辽宁省污水综合排放标准》。

关 键 词:稠油采出水  水解酸化  曝气生物固定床滤池  活性焦  吸附  
收稿时间:2015-11-10

Pilot test for treatment of heavy oil produced water
Wang Fei.Pilot test for treatment of heavy oil produced water[J].Environmental Protection of Chemical Industry,2016,36(4):439-442.
Authors:Wang Fei
Institution:Daqing Oilfield Water Company,CNPC,Daqing Heilongjiang 163000,China
Abstract:Using activated coke as adsorbent,a pilot test for treatment of heavy oil produced water was carried out by the combination process of pre-adsorption-hydrolysis acidification-fixed-bed biological aerated filtration-post-adsorption. The test results show that when the influent COD of the pre-adsorption is 408.6-526.7 mg/L,the return flows of activated coke for the pre-adsorption tank is 25%,the up-flow velocity of the hydrolysis acidification tank is 0.22 m/h,the air-water ratio of the fixed-bed biological aerated filter is 10∶1 and the dosage of activated coke in the post-adsorption tank is 2 kg,the COD removal rate of the heavy oil produced water reaches 90.0%,and the average of effluent COD is 46.2 mg/L,which meets the Liaoning integrated wastewater discharge standard of DB21/1627-2008.
Keywords:heavy oil produced water  hydrolysis acidification  fixed-bed biological aerated filter  activated coke  adsorption
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《化工环保》浏览原始摘要信息
点击此处可从《化工环保》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号