细水雾抑制熄灭K类火有效性的实验研究
引用本文:杨冬雷,房玉东,刘江虹,金翔,廖光煊.细水雾抑制熄灭K类火有效性的实验研究[J].火灾科学,2006,15(1):26-30.
作者姓名:杨冬雷  房玉东  刘江虹  金翔  廖光煊
作者单位:中国科学技术大学,火灾科学国家重点实验室,安徽,合肥,230027
基金项目:国家重点基础研究发展计划(973计划);中国科学院资助项目
摘    要:本文通过全尺寸模拟实验研究了细水雾与K类火的相互作用,利用LDV/APV激光多普勒分析仪对细水雾特性进行了测量,分析了细水雾的粒径、速度及雾动量对灭火有效性的影响规律。分别改变喷头类型、工作压力、喷头与火源的垂直距离及喷射角度进行多种工况的灭火实验,结果表明,细水雾的灭火有效性随着压力的增大得到明显提高,喷头的雾化性能直接影响着细水雾的灭火有效性,同时喷射角度及喷射距离也影响着细水雾的灭火有效性。本文为细水雾灭火技术用于厨房环境的火灾防护提供了科学的参考依据和必要的设计参数。

关 键 词:细水雾  K类火  灭火有效性
文章编号:1004-5309(2006)-0026-05
收稿时间:2005-09-01
修稿时间:2005-11-25

Experimental Research on Efficiency of Extinguishing Cooking Oil Fires by Water Mist
YANG Dong-lei,FANG Yu-dong,LIU Jiang-hong,JIN Xiang and LIAO Guang-xuan.Experimental Research on Efficiency of Extinguishing Cooking Oil Fires by Water Mist[J].Fire Safety Science,2006,15(1):26-30.
Authors:YANG Dong-lei  FANG Yu-dong  LIU Jiang-hong  JIN Xiang and LIAO Guang-xuan
Institution:State Key Laboratory of Fire Science,University of Science and Technology of China,230028,China;State Key Laboratory of Fire Science,University of Science and Technology of China,230029,China;State Key Laboratory of Fire Science,University of Science and Technology of China,230030,China;State Key Laboratory of Fire Science,University of Science and Technology of China,230031,China;State Key Laboratory of Fire Science,University of Science and Technology of China,230032,China
Abstract:In this paper the interaction of cooking oil fires with water mist is studied by full scale experiments. The diameter and velocity of the droplet used in the experiments are measured by LDV/APV systems. Effect of the diameter, velocity and momentum of water mist on fire controlling and extinguishing efficiency are investigated. Fire extinguishment experiments with different nozzles, different pressures, different spray distances and different spray angles are performed. Results show that water mist system with suitable parameters can put out the cooking oil fires effectively without reigniting phenomena. Spray angle and spray distance also affect the fire extinguishment efficiency of water mist. Reasonable conditions and designing parameters for practical engineering application of water mist are suggested.
Keywords:Water Mist  Cooking Oil Fires t Fire Extinguishing Efficiency