首页 | 本学科首页   官方微博 | 高级检索  
     


Modification of chemical oxygen demand monitoring in the Yellow River, China, with a high content of sediments.
Authors:Jinren Ni  Liyiing Sun  Weiling Sun
Affiliation:Department of Environmental Engineering, Peking University, Beijing, China. nijinren@iee.pku.edu.cn
Abstract:This paper presents a modification of chemical oxygen demand (COD) monitoring giving a better indication of the pollution level compared with the conventional COD method for rivers with a high content of sediments. The correlation between the sediment organic carbon and COD was investigated using sediments sampled in the middle Yellow River, China. Partitioning of the sediment organic carbon between the water and sediment phases was also investigated using batch experiments, with the sediment concentration varying from 20 to 400 g/L. As a result, the COD modification equations are proposed for both turbid water (mixture of water and sediment) and supematant water (filtrate using a 0.45-microm membrane). The modified COD in turbid water and supernatant water could be 40 and 10% less than the monitored COD values, respectively. These results may have a significant influence on the assessment of water quality class in the Yellow River.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号