首页 | 本学科首页   官方微博 | 高级检索  
     检索      

国产火焰型原子吸收分光光度计的使用与维护
引用本文:罗颂伟.国产火焰型原子吸收分光光度计的使用与维护[J].中国环境监测,1997(5).
作者姓名:罗颂伟
作者单位:广东省梅州市环境监测站
摘    要:本文分析了国产火焰型原子吸收分光光度计的结构原理和特点,指出他们的优势和缺陷;根据实践经验,总结了仪器的调试,使用和维护的方法和程序;同时分析一些仪器故障的产生原因及排除方法。对保障仪器的准确高效运转有一定的参考价值

关 键 词:火焰原子吸收,国产仪器,调试,使用,维护

Using and Maintaining the Fire Atomic Absorption Spectromatre Made in China.
Luo Song wei.Using and Maintaining the Fire Atomic Absorption Spectromatre Made in China.[J].Environmental Monitoring in China,1997(5).
Authors:Luo Song wei
Abstract:In this paper,it has analysed the principle and characteristic of the structure of the Fire Atomic Absorption Spectromatre made in China,and pointed out the Superiority and defect.According to the practice,it's summarized some methods and programs of adjusting,using and maintaining the instrument.It has both analysed the trouble of the instrument and the cause,and offered the solution.The article is a valuable reference to keep the instrument work accurately and efficiently.
Keywords:Fire Atomic Absorption  instrument made in China  adjust  use  maintain  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国环境监测》浏览原始摘要信息
点击此处可从《中国环境监测》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号