稀释接种法测BOD5考核样品的一些注意点
引用本文:冯胜.稀释接种法测BOD5考核样品的一些注意点[J].云南环境科学,2011,30(4):90-92.
作者姓名:冯胜
作者单位:常熟环境监测站,江苏,常熟,215500
摘    要:用稀释接种法测定BOD5时,由于操作繁琐,全部实验时间需要5d,任一环节出现问题都会影响实验结果。在进行考核实验时,由于时间紧,样品量有限,因此每个实验操作步骤都要谨慎仔细。通过实践经验,就BOD,考核实验总结了一些注意点。

关 键 词:BOD5  考核样品  注意点

Quality Control on Assessing Samples of BOD5 by Dilution and Seeding Method
FENG Sheng.Quality Control on Assessing Samples of BOD5 by Dilution and Seeding Method[J].Yunnan Environmental Science,2011,30(4):90-92.
Authors:FENG Sheng
Institution:FENG Sheng (Changshu Environmental Monitoring Station, Changshu Jiangsu 215500 China)
Abstract:It is complicated to determine BOD5 by dilution and seeding method because of its long time of 5 days and other unexpected factors existed in any Steps of the whole process. Some experiences of BOD5 assessment of quality control were summarized to avoid tight time and limited samples.