Abstract:We examined the concentration, size distribution, redox state and isotopic composition of plutonium (Pu) in groundwater at the 100K-Area at the U.S. Department of Energy's (DOE) Hanford Site. Total concentrations of Pu isotopes were extremely low (10(-4) to 10(-6) pCi/kg, approximately 10(4) to 10(6) atoms/kg) but measurable for the first time in the 100K-Area wells using mass spectrometric analyses that are much more sensitive than alpha spectroscopy methods used previously. Size fractionation data from two wells suggest that 7-29% of the Pu is associated with colloids, operationally defined here as particles between 1 kDa-0.2 microm in size. These colloids were collected using a 1 kDa cross-flow ultrafiltration (CFF) system developed specifically for groundwater actinide studies to include careful controls both in the field and during processing to ensure in situ geochemical conditions are maintained and size separations can be well characterized. Pu in this colloidal fraction was exclusively in the more reduced Pu(III/IV) form, consistent with the higher affinity of Pu in the lower oxidation states for particle surfaces. While the overall concentrations of Pu were low, the Pu isotopic composition suggests at least two local sources of groundwater Pu, namely, local Hanford reactor operations at the 100K-Area and spent nuclear fuel from the N-reactor, which was stored in concrete pools at this site. Differences between this site and the Savannah River Site (SRS) are noted, since groundwater Pu at the F-Area seepage basin at SRS has been found using these same methods, to be characterized by lower colloidal abundances and higher oxidation states. This difference is not directly attributable to groundwater redox potential or geochemical conditions, but rather the physical-chemical difference in Pu sources, which at SRS appear to be dominated downstream from the seepage basins by decay of 244Cm, resulting in more oxidized forms of 240Pu. There is no clear evidence for colloid facilitated transport of Pu in groundwater at the Hanford Site, since downstream wells have both an order of magnitude lower concentrations of Pu and a lower fractional colloidal distribution.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号