首页 | 本学科首页   官方微博 | 高级检索  
     

液液萃取-气相色谱法测定水质可萃取性石油烃C10~C40
引用本文:殷惠民,董亮,李玲玲,钮珊,张辉,刘金林. 液液萃取-气相色谱法测定水质可萃取性石油烃C10~C40[J]. 中国环境监测, 2018, 34(2): 83-88
作者姓名:殷惠民  董亮  李玲玲  钮珊  张辉  刘金林
作者单位:国家环境保护二噁英污染控制重点实验室国家环境分析测试中心;环境保护部环境发展中心;北京化工大学
基金项目:国家环境保护标准项目(2014-37)
摘    要:建立了以环己烷为萃取剂、气相色谱法(氢火焰离子化检测器,FID)测定水质样品中可萃取性石油烃(C_(10)~C_(40))的分析方法。以正构烷烃混合标准溶液为定性和定量校准标准,以色谱峰面积总和与混合标准溶液总浓度建立校准曲线进行外标法定量。方法检出限为0.01 mg/L,经验证方法精密度和准确度良好。同时,分别以气相色谱法和红外光度法测定了地表水、污水处理厂出水、海水和化工废水等实际样品,对比实验结果表明,在可萃取性石油烃C_(10)~C_(40)的碳数范围内,气相色谱法的测试结果与红外光度法无明显差异,有较好的可比性。

关 键 词:石油烃  气相色谱法  液液萃取
收稿时间:2016-09-21
修稿时间:2016-11-22

Determination of Extractable Petroleum Hydrocarbons (EPH) C10-C40 in Water by Liquid-Liquid Extraction and Gas Chromatography
YIN Huimin,DONG Liang,LI Lingling,NIU Shan,ZHANG Hui and LIU Jinlin. Determination of Extractable Petroleum Hydrocarbons (EPH) C10-C40 in Water by Liquid-Liquid Extraction and Gas Chromatography[J]. Environmental Monitoring in China, 2018, 34(2): 83-88
Authors:YIN Huimin  DONG Liang  LI Lingling  NIU Shan  ZHANG Hui  LIU Jinlin
Affiliation:State Environmental Protection Key Laboratory of Dioxin Pollution Control, National Research Center for Environmental Analysis and Measurement, Beijing 100029, China,State Environmental Protection Key Laboratory of Dioxin Pollution Control, National Research Center for Environmental Analysis and Measurement, Beijing 100029, China,Environmental Development Centre of Ministry of Environmental Protection, Beijing 100029, China,State Environmental Protection Key Laboratory of Dioxin Pollution Control, National Research Center for Environmental Analysis and Measurement, Beijing 100029, China;Beijing University of Chemical and Technology, Beijing 100029, China,State Environmental Protection Key Laboratory of Dioxin Pollution Control, National Research Center for Environmental Analysis and Measurement, Beijing 100029, China and State Environmental Protection Key Laboratory of Dioxin Pollution Control, National Research Center for Environmental Analysis and Measurement, Beijing 100029, China
Abstract:A method of liquid-liquid extraction and gas chromatography (flame ionization detector, FID) analysis was developed for extractable petroleum hydrocarbons C10-C40 in water. N-alkanes were used as qualitative and quantitative standards and the standard curve was established between total peak area and total concentration for external standard quantification. The detection limit of petroleum C10-C40 was 0.01 mg/L. Precision and accuracy of the method were both satisfying. Analysis results were compared between gas chromatography and infrared spectrophotometry when determining petroleum in actual samples of surface water, effluent of municipal wastewater treatment plant,seawater and chemical industry wastewater. It was found that there was no significant difference between the results of EPH C10-C40 analyzed by GC-FID and infrared spectrophotometry. Results of two methods had good comparability.
Keywords:petroleum hydrocarbons  GC-FID  liquid-liquid extraction
本文献已被 CNKI 等数据库收录!
点击此处可从《中国环境监测》浏览原始摘要信息
点击此处可从《中国环境监测》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号