杭钢1~#6000m~3/h制氧漏冷基础裂缝事故处理 |
| |
作者单位: | 杭钢集团公司设备处!杭州310020 |
| |
摘 要: | 杭钢动力厂走梯旁基础与地坪连接处出现一条裂缝 ,致使空分设备出现漏冷。该厂在检测、分析后 ,没有采取将空分塔体拆除、基础重浇的惯例 ,而是采取了将空分塔体地脚螺栓加固的方案 ,取得了很好的效果。
|
关 键 词: | 空分塔 漏冷 基础裂缝 处理 |
Method for cracks treatment on air-separating tower base of the No.1 oxygen-making machine of hang gang |
| |
Authors: | Yang Lunguang |
| |
Abstract: | A crack appeared in the junction between the base of the aisle ladder and the ground of the power plant and made cool leakage on airseparating aguipment. After analysis and detection,a new method was adopted by the plant with the reinforcement of the foundation screws of the airseparating tower and a good result was achieved. |
| |
Keywords: | airseparating tower cool leakage base cracks treatment |
本文献已被 CNKI 等数据库收录! |