首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Meister
Authors:Rainer Haus  Klaus Schäfer  Herbert Mosebach
Institution:1. Fraunhofer-Institut für Atmosph?rische Umweltforschung, Rudower Chaussee 5, D-12489, Berlin
2. Fraunhofer-Institut für Atmosph?rische Umweltforschung, Kreuzeckbahnstr. 19, D-82467, Garmisch-Partenkirchen
3. Fraunhofer-Institut für Atmosph?rische Umweltforschung, Kayser-Threde GmbH, Wolfratshauser Str. 48, D-81379, München
Abstract:A mobile remote sensing system is presented for measuring the concentration of gaseous pollutants in ambient air and in directed effluent streams. MEISTER is based on Fourier-Transform-Infrared-Spectroscopy (FTIS), which is predestinated for a simultaneous analysis of a large number of atmospheric gases. The Kayser-Threde Double-Pendulum interferometer K300 and the Multicomponent Air Pollution Software (MAPS) of the Fraunhofer Institute of Atmospheric Environmental Research, which is based on radiative transfer modeling and least square fit procedures, enable a concentration determination under almost all meteorological conditions. CO, CO2, NO, N2O, CH4, H2O and HCl concentrations have been determined in good agreement with results from conventionalin situ sensors. NO2, SO2, NH3, HCHO and hydrocarbons have been successfully detected provided their concentrations were high enough.
Keywords:
本文献已被 SpringerLink 等数据库收录!