首页 | 本学科首页   官方微博 | 高级检索  
     检索      

氨氮测定中采用蒸馏法处理样品时加碱中和的探讨
引用本文:肖福东.氨氮测定中采用蒸馏法处理样品时加碱中和的探讨[J].云南环境科学,2003,22(Z1):179-180.
作者姓名:肖福东
作者单位:肖福东(德宏州环境监测站,云南,潞西,678400)
摘    要:采用纳氏试剂测定氨氮时,加入不同量的NaOH溶液对纳氏反应影响较大,经过多次实验,认为加入5ml25%NaOH中和10ml硼酸最合适.

关 键 词:氨氮测定  蒸馏法  监测分析
文章编号:1006-947X(2003)增-0179-02
修稿时间:2003年2月25日

Discussion on Adding Alkali to the Sample Which is Treated by Distillation in the Process of Ammonia Nitrogen Determination
XIAO Fu-dong.Discussion on Adding Alkali to the Sample Which is Treated by Distillation in the Process of Ammonia Nitrogen Determination[J].Yunnan Environmental Science,2003,22(Z1):179-180.
Authors:XIAO Fu-dong
Abstract:When we determinate the concentration of ammonia nitrogen by adding the Nessler's reagent, we add different quality alkali to it, this takes big effect on the Nessler's reagent method, after many experiments, we think that it is the fittest to add 0.5ml, 25% sodium hydroxide (NaOH) neutralizing 10ml boric acid.