GB4943与UL94的水平燃烧试验的区别
引用本文:谢苗山,武政,裴晓波. GB4943与UL94的水平燃烧试验的区别[J]. 环境技术, 2010, 28(1): 29-31
作者姓名:谢苗山  武政  裴晓波
作者单位:广东出入境检验检疫局检验检疫技术中心电气安全实验室
摘    要:就GB4943-2001《信息技术设备的安全》的附录A8与UL94中关于50W水平燃烧试验的区别,说明了水平燃烧试验过程中应注意的几个问题,以及确定材料燃烧等级试验的重要性。通过分析,加深对标准中水平燃烧试验要求的理解。

关 键 词:水平燃烧  区别

The Difference of Horizontal Flame Test Between GB4943 and UI94
XIE Miao-shan,WU Zheng,PEI Xiao-bo. The Difference of Horizontal Flame Test Between GB4943 and UI94[J]. Environmental Technology, 2010, 28(1): 29-31
Authors:XIE Miao-shan  WU Zheng  PEI Xiao-bo
Affiliation:XIE Miao-shan WU Zheng PEI Xiao-bo
Abstract:According to the differences of 50W horizontal flame testmethod betweenAppendix A8 in GB4943-2001 "Safety of information technology equipment" and UL94,expatiating on several issues during horizontal flame test,and emphasize the importance of the test of determining the material flammability class.Through analysis,deepen the understanding of the horizontal flame test requirements in the standard.
Keywords:horizontal flame  difference  