首页 | 本学科首页   官方微博 | 高级检索  
     

大流量孔口流量计的校准、数据处理及误差分析
引用本文:龚雪平,丁 芸. 大流量孔口流量计的校准、数据处理及误差分析[J]. 环境科学研究, 1997, 10(6): 53-57
作者姓名:龚雪平  丁 芸
作者单位:1.中国环境监测总站,北京 100029
摘    要:用罗兹流量计校准孔口流量计,用温度和大气压力对孔口流量计的负压进行修正,使孔口流量计的流量和压力修正项间的关系为一直线,得到孔口流量计的标准曲线并评价其精度。探讨了孔口流量计流量不确定度的主要来源,为精度控制提供了理论依据。 

关 键 词:罗兹   孔口   精度   不确定度
收稿时间:1996-04-15

Calibration of High volume Orifice Flowmeter and Its Data Process, Error Analysis
GONG Xueping and DING Yun. Calibration of High volume Orifice Flowmeter and Its Data Process, Error Analysis[J]. Research of Environmental Sciences, 1997, 10(6): 53-57
Authors:GONG Xueping and DING Yun
Affiliation:1.China Station of Environmental Monitoring, Beijing 1000292.Resources and Environment Department, Beijing Normal University, Beijing 100875
Abstract:Orifice flowmeter was calibrated by Roots flowmeter, and the offset pressure, a negative pressure, was corrected by temperature and atmospheric pressure. The calibration curve, which shows that the relation between flow fate and offset pressure, was modified as a line and its precision was assessed. The main sources of the orifice flowrate' uncertainty were discussed, and then the theory basis for the precision control was provided.
Keywords:Roots  Orifice  Precision  Uncertainty  
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《环境科学研究》浏览原始摘要信息
点击此处可从《环境科学研究》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号