首页 | 本学科首页   官方微博 | 高级检索  
     

燃煤锅炉烟气中一氧化氮排放浓度测量的不确定度评定
引用本文:李健,李永亮,牟学军,邵茂华. 燃煤锅炉烟气中一氧化氮排放浓度测量的不确定度评定[J]. 内蒙古环境科学, 2011, 0(9): 183-184
作者姓名:李健  李永亮  牟学军  邵茂华
作者单位:佳木斯市环境保护监测站,黑龙江154004
摘    要:根据《测量不确定度评定与表示》(JJF1059-1999),对燃煤锅炉烟气中一氧化氮排放浓度的测量不确定度进行评定。对废气监测领域不确定度评定具有现实意义。

关 键 词:一氧化氮  测量  不确定度

Uncertainty Assessment for the Measure of Nitric Oxide in Coal-fired Boiler Flue Gas
Li Jian,Li Yongliang,Mou Xuejun,Shao Maohua. Uncertainty Assessment for the Measure of Nitric Oxide in Coal-fired Boiler Flue Gas[J]. Inner Mongolia Environmental Protection, 2011, 0(9): 183-184
Authors:Li Jian  Li Yongliang  Mou Xuejun  Shao Maohua
Affiliation:(Jiamusi Environmental Monitoring Station,Hei Longjiang 154004)
Abstract:Analysis of the uncertainty in measure of Nitric Oxide in Coal-fired boiler flue gas is according to the 'Evaluation and Expression of Uncertainty in Measurement'(JJF1059-1997).And is instructive to assess for waste gas monitoring.
Keywords:nitric oxide  measure  uncertainty
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号