Evaluation of energy savings by using high efficiency motors in a thermal power station
Authors:Mohamed Kaddari  Mahmoud El Mouden  Abdelowahed Hajjaji
Institution:Laboratory of Engineering Sciences for Energy (LabSIPE), Chouaib Doukkali University-National School of Applied Sciences (ENSAJ), El Jadida, Morocco
Abstract:This paper presents potential energy savings by installing high-efficiency motors instead of existing ones and their impact on greenhouse gases emissions reductions. This research study of the energy efficiency of electric motors has been performed in a typical thermal power plant. In the literature, the focus has been mainly on separate and away electric motors from operating facilities. The important advantage of this paper over other studies is that it uses the actual motors’ efficiency in the evaluation. The gains both in terms of electrical energy savings and in terms of financial economy by using high-efficiency motors have been discussed. As a result, the energy saving can be expected as 12.6% at the operating rate. This excellent result also reduces greenhouse gas emission by 1,423 tons every year. The analysis of the data provided an overview on energy losses often generated by the degradation and rewinding of electrical motors. This study represents very encouraging results that will help energy managers of industrial plants to become more involved in energy efficiency strategies.
Keywords:Efficiency  electric motor  energy savings  greenhouse gases  payback period  thermal power plant