摘    要:介绍了华能北京热电厂液态排渣塔式直流炉4号电除尘器电源控制系统改造后所取得的成果.该电厂采用了ZH2005型控制器,烟尘排放质量浓度达到20mg/m3左右,可节省电费58万元/a,减排粉尘120t/a.

关 键 词:电除尘器  高压电源  反电晕放电

Energy-saving measures of electrostatic precipitator in coal-fired power plants
MA Jin-hui,WANG Rong-hua,YAN Ke-ping.Energy-saving measures of electrostatic precipitator in coal-fired power plants[J].Electric Power Environmental Protection,2008,24(6).
Authors:MA Jin-hui  WANG Rong-hua  YAN Ke-ping
Abstract:The successful application of ZH2005 controller on the ESP reformation project in Huaneng Beijing Power Plant No.4 boiler was introduced.The dust concentration of ESP outlet emission was below 20mg/m3 and a total dust reduction of 120tons per year with an electric power conservation cost reduction about 580 thousand yuan per year were achieved through the application of ZH2005 controller.