Laser induced fluorescence instrument for NO2 measurements: Observations at a central Italy background site
Authors:Cesare Dari-Salisburgo  Piero Di Carlo  Franco Giammaria  Yoshizumi Kajii  Alfonso D'Altorio
Institution:1. Center of Excellence CETEMPS, Universita’ degli studi di L''Aquila, Via Vetoio, 67010 Coppito, L''Aquila, Italy;2. Dipartimento di Fisica, Universita’ degli studi di L''Aquila, Via Vetoio, 67010 Coppito, L''Aquila, Italy;3. Department of Applied Chemistry, Graduate School of Engineering, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji, Tokyo 192-0397, Japan;2. Service d''Hématologie Adultes, Hôpital Necker-Enfants Malades, Paris, France;3. Service d''Hématologie, Pavillon Marcel Bérard, Centre Hospitalier Lyon-Sud 165, Pierre Bénite Cedex, France;1. Division of Cardiology & Angiology, Bergmannsheil, Ruhr-University Bochum, Bochum, Germany;2. Division of Pneumology and Sleep-Center and Bergmannsheil, Ruhr-University Bochum, Bochum, Germany;3. Division of Endocrinology and Diabetes, Bergmannsheil, Ruhr-University Bochum, Bochum, Germany;4. Heart Center Bad Neustadt, Clinic for Electrophysiology, Bad Neustadt, Germany;5. Division of Cardiology of the University Hospital Düsseldorf, Düsseldorf, Germany;6. Cardiovascular Center, St. Josef-Hospital, Ruhr-University Bochum, Germany
Abstract:A laser induced fluorescence (LIF) instrument has been developed to measure tropospheric NO2 with low detection limit. The instrument design, development and first measurements are reported. There are also details of the temporal gate system built for the fluorescence acquisition. The instrument is able to make fast measurements (up to 4 Hz) and shows a limit of detection of 10 pptv/60 s. Continuous observations (2 weeks in summer 2007) in a small town in central Italy were used to test the performance of the instrument and to study the photochemistry of ozone in a background site. LIF and a commercial chemiluminescence (CL) instrument simultaneous observations of NO2 show a good linearity (LIF = 1.02 CL + 0.6 (ppb), R2 = 0.98) but there is a bias of the commercial instrument of about 0.60 ppbv on average. The overestimation of the CL system is probably due to conversion of NOy species into NO by the molybdenum converter used in the CL instrument to detect NO2. Analysis of 1 s data is used to test the instrument response and the coupling between nitrogen oxides and ozone.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号