首页 | 本学科首页   官方微博 | 高级检索  
     检索      

FGD无旁路情况下增压风机故障触发锅炉RB功能的应用
引用本文:吴志刚.FGD无旁路情况下增压风机故障触发锅炉RB功能的应用[J].电力环境保护,2014(4):61-62.
作者姓名:吴志刚
作者单位:国电宁夏石嘴山发电有限责任公司,宁夏石嘴山753202
摘    要:根据国家环保部“十二五”规划,持续推进污染物总量减排工作,燃煤发电机组将取消旁路,对无脱硫旁路挡板的机组,脱硫系统( FGD)增压风机故障后为避免机组产生非停,而触发快速减负荷( RB)功能,指出在触发RB功能的同时应该注意的事项和应采取的技术措施;对于防止机组非正常停机、提高电网稳定性具有重要意义。

关 键 词:无旁路  增压风机故障  RB功能

Application of blower fan fault trigger boiler RB function of FGD without bypass
Abstract:According to the national environmental protection the 12th five-year plan,coal-fired power genera-ting units wil cancellbypass. ln no desulfurization bypass unit,in order to avoid to produce Abnormal downtime after blower fan fault of desulfurization( FGD)system,and trigger the rapid load reduction( RB)function, pointed out that in trigger RB and the matters should some mentions and technical measures are pointed out. lt has a great significance to prevent abnormal downtime and improve the stability of power grid.
Keywords:FGD  without the bypass  FGD  blower fan fault  RB function
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号