首页 | 本学科首页   官方微博 | 高级检索  
     

水中氯离子对氨氮测定的影响及消除
引用本文:沈丽丽,青华. 水中氯离子对氨氮测定的影响及消除[J]. 干旱环境监测, 2009, 23(1): 59-60
作者姓名:沈丽丽  青华
作者单位:新疆环境监测总站,新疆乌鲁木齐,830011;新疆环境监测总站,新疆乌鲁木齐,830011
摘    要:分析了不同浓度氯离子对水中氨氮测定的影响,并对其消除方法进行了探讨。实验结果表明,氯离子在一定范围内对氨氮的测定产生影响,用蒸馏比色法可以消除氯离子的干扰,误差〈5%。实际样品加标回收率为93%~97%,结果令人满意。

关 键 词:氯离子  氨氮  影响

Effect and Elinmination of ChiloridIon to Ammonia Nitrogen Determination in Water
SHEN Li-li,QING Hua. Effect and Elinmination of ChiloridIon to Ammonia Nitrogen Determination in Water[J]. Arid Environmental Monitoring, 2009, 23(1): 59-60
Authors:SHEN Li-li  QING Hua
Affiliation:Xinjiang Environmental Monitoring General Station;Urumqi Xinjiang 830011;China
Abstract:Elimination effect of different Cl-concentration to Ammonia Nitrogen determination was investigated through experiments.The results showed that Clcould effect the determination of Ammonia Nitrogen in the different range,and elinmination method was comparable with distillation.
Keywords:chloric ion  ammonia nitrogen  effect  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号