摘    要:分析了不同浓度氯离子对水中氨氮测定的影响,并对其消除方法进行了探讨。实验结果表明,氯离子在一定范围内对氨氮的测定产生影响,用蒸馏比色法可以消除氯离子的干扰,误差〈5%。实际样品加标回收率为93%~97%,结果令人满意。

关 键 词:氯离子  氨氮  影响

Effect and Elinmination of ChiloridIon to Ammonia Nitrogen Determination in Water
SHEN Li-li,QING Hua.Effect and Elinmination of ChiloridIon to Ammonia Nitrogen Determination in Water[J].Arid Environmental Monitoring,2009,23(1):59-60.
Authors:SHEN Li-li  QING Hua
Institution:Xinjiang Environmental Monitoring General Station;Urumqi Xinjiang 830011;China
Abstract:Elimination effect of different Cl-concentration to Ammonia Nitrogen determination was investigated through experiments.The results showed that Clcould effect the determination of Ammonia Nitrogen in the different range,and elinmination method was comparable with distillation.