摘    要:采用超低压反渗透膜处理垃圾渗滤液,考察不同工艺条件下膜通量、脱盐率、COD和NH3-N去除率的变化规律.实验结果表明,不同压力条件下对应某一输出频率存在最大膜通量.在输出频率变化方面,压力高的最大膜通量滞后于压力低的最大膜通量.运用变频调速技术,可实时解决操作压力与泵送流量的对应关系,确定最佳流量参数,提高反渗透系统运...

关 键 词:超低压  反渗透  垃圾填埋  渗滤液  运行工艺

Experimental study on running processes of landfill leachate treatment by ultra-low reverse osmosis membrane
Guo Jian,Wu Jiaqian,Xian Ping,Wang Xiaoying,Jiang Linling,Lü Caiping. Experimental study on running processes of landfill leachate treatment by ultra-low reverse osmosis membrane[J]. Techniques and Equipment for Environmental Pollution Control, 2011, 5(3): 553-556
Authors:Guo Jian  Wu Jiaqian  Xian Ping  Wang Xiaoying  Jiang Linling  Lü Caiping
Affiliation:School of Environment, Guangxi University,Nanning 530004,China,Guangxi Environmental Monitoring Central Station, Nanning 530022,China,School of Environment, Guangxi University,Nanning 530004,China,School of Environment, Guangxi University,Nanning 530004,China,School of Environment, Guangxi University,Nanning 530004,China and School of Environment, Guangxi University,Nanning 530004,China
Abstract:The ultra-low reverse osmosis membrane was used to process landfill leachate in order to test the variations of flux of membrane, desalination rate, the removal rate of COD and NH3-N under different technical conditions. The research results indicate that a maximum flux is corresponding to a certain output frequency under various pressure conditions. In terms of the changing of the output frequency, the maximum membrane flux at high pressure lags behind that at low pressure. Using the frequency conversion velocity modulation technology, the corresponding relationship between the operating pressure and the pump flow rate in real-time can be solved, optimum flow parameters can be obtained, and the efficiency of the ultra-low reverse osmosis membrane system can be enhanced. The flux of membrane and the desalination rate increase along with the increment of pressure, but the growth rate slows down. The suitable pressure could be set to 0.8~0.9 MPa. Changing the pH value has smaller influence on the removal rate of COD and NH3-N, but has greater impact on the desalination rate. When pH increases the flux of membrane reduces. The suitable scope of pH of landfill leachate should be ranged from 7.5 to 8.5. The flux of membrane and the desalination rate decrease along with the increment of the influent conductivity, and the influent conductivity should be no more than 18 mS/cm.
Keywords:ultra-low voltage   reverse osmosis   municipal solid waste landfill   landfill leachate   running process