Two-phase jet releases,droplet dispersion and rainout,II. Rainout experiments
Authors:Richard J Bettis  Stuart F Jagger  Henk WM Witlox  Michael Harper
Institution:1. HSL Fire and Process Safety, Harpur Hill, Buxton, Derbyshire SK17 9JN, UK;2. DNV Software, Palace House, 3 Cathedral Street, London SE1 9DE, UK
Abstract:This paper describes the results of the first experimental stage of Phase IV of a Joint Industry Project (JIP) on liquid jets and two-phase droplet dispersion. The objective of this stage of the JIP was to generate experimental rainout data for non-flashing water and xylene experiments. See the overview companion paper I for a wider overview of the problem, model implementation and associated model validation.A range of orifice sizes (2.5 and 5 mm) and stagnation pressures (4–16 barg) were applied. Measurements included flow rate, initial droplet size, plume concentrations/temperatures for a range of downstream locations, and distributed rainout.Instead of the Phase Doppler Anemometry method used for droplet size measurements earlier in the JIP, a photographic technique was applied in an attempt to include measurement of the larger (non-spherical) droplets. This enabled a more accurate evaluation of the initial droplet size distribution and a much clearer understanding of the droplet morphology. The results showed that the droplet behaviour in the jet is more complex than had been anticipated with the mass distribution dominated by a very small number of large non-spherical droplets. Consequently a large number of spray images were required to evaluate an accurate size distribution.Distributed rainout was measured by weighing the amount of rainout in trays positioned along the jet direction. The rainout results showed a good degree of repeatability and internal consistency. They indicated that an increasing proportion of the released material did not rainout for increasing pressure. Rainout distance also increased with increasing pressure. Evaporation of the liquid was confirmed by temperature measurements, which showed the effect of evaporative cooling.Xylene concentration measurements (up to 1%) were carried out using a direct reading photoionization detector calibrated for xylene (measuring vapour only). For a limited dataset, the accuracy of these measurements was estimated by means of comparison against an alternative more time-consuming concentration method (xylene absorption onto a charcoal filter; measuring both vapour and liquid). The concentration measurements displayed several consistent qualitative features. For example, at a given downstream distance, the peak concentration increases with increasing pressure and nozzle diameter and the vertical height at which the peak is achieved increases. The cross-stream profiles displayed a consistent tendency to increased concentration at the edge of the jet, and the reason for this has not been established.Finally recommendations are provided for potential future work.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号