Laboratory stabilization/solidification of tank sludges: GAAT, OHF, and combined tank sets |
| |
Authors: | Spence R D Mattus C H |
| |
Affiliation: | Oak Ridge National Laboratory, Chemical Technology Division, P.O. Box 2008 Oak Ridge, Tennessee 37831-6202, USA. spencerd@ornl.gov |
| |
Abstract: | Highly radioactive, mixed-waste sludges that have been collected at Oak Ridge over several decades are being combined for treatment and disposal. Stabilization of the sludges in the different tank sets was tested prior to the proposed combination and treatment. This paper, which follows a previous article on the Melton Valley Storage Tank/Bethel Valley Evaporator Storage Tank set, documents the testing of the Gunite and Associated Tank and Old Hydrofracture Facility tank sets, as well as the combined sludges of all the Oak Ridge National Laboratory tank sets; the third paper on this subject will discuss efforts to maximize the sludge loading. The grout formulations were tested in the laboratory with surrogates. A wet-sludge loading of 60wt% resulted in strong wasteforms with no free water and gave a volume increase of about 30-40vol%. The Resource Conservation and Recovery Act metals included in the surrogate testing were silver, cadmium, chromium, lead, selenium, thallium, zinc, and mercury. The grout formulations stabilized these metals within the Universal Treatment Standards limits. In addition, a grout leachability index of about 10.0-12.0 was measured for both (85)Sr and (137)Cs, meeting the recommended requirement of >6.0. |
| |