首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Boron removal from produced water using electrocoagulation
Institution:1. Hacettepe University, Chemical Engineering Department, 35100 Izmir, Turkey;2. Ege University, Chemical Engineering Department, 35100 Izmir, Turkey
Abstract:Produced water is the largest wastestream of oil and gas exploration but its chemical composition hinders its beneficial use. Effective treatment and reuse of produced water can mitigate scarcity of fresh water, especially in arid areas. Presence of inorganic compounds such as boron in produced water renders its beneficial use difficult. In this study, boron removal from produced water was investigated. Synthetic wastewater was prepared simulating the range of boron concentrations in produced water. Four operating parameters pH (3–11), charge loading (1200–3600 Ah/m3), contact time (15–90 min) and concentration (10–30 mg/L) were selected and their optimum conditions investigated. The obtained optimum conditions were applied to treat real produced water. Residual boron concentration of 0.3 mg/L was obtained from initial boron concentration of 15 mg/L in real produced water at optimum conditions of pH 7, charge loading 2400 Ah/m3 and contact time 90 min. Boron adsorption could be represented by Langmuir and Freundlich isotherm models. Electrocoagulation can be used for the effective removal of boron from produced water.
Keywords:Boron  Electrocoagulation  Produced water  Adsorption  Isotherms
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号