首页 | 本学科首页   官方微博 | 高级检索  
     


Development of in-house ELISA for detection of chloramphenicol in bovine milk with subsequent confirmatory analysis by LC-MS/MS
Authors:Muhammad I. Chughtai  Uzma Maqbool  Mazhar Iqbal  Muhammad S. Shah  Terence Fodey
Affiliation:1. Veterinary Drug Residue Laboratories, Animal Sciences Division, Nuclear Institute for Agriculture and Biology (NIAB), Faisalabad, Pakistan;2. Chemical and Immunodiagnostic Sciences Branch, Agri-Food and Biosciences Institute (AFBI), Stormont, Belfast, Northern Ireland, United Kingdom;3. Drug Discovery and Structural Biology Group, Health Biotechnology Division, National Institute for Biotechnology and Genetic Engineering (NIBGE), Faisalabad, Pakistan;4. Chemical and Immunodiagnostic Sciences Branch, Agri-Food and Biosciences Institute (AFBI), Stormont, Belfast, Northern Ireland, United Kingdom
Abstract:This study was undertaken to develop and validate direct competitive ELISA for the determination of chloramphenicol residues in bovine milk. Antisera and an enzyme-tracer for chloramphenicol were prepared and used to develop an ELISA with inhibition concentrations, IC20 and IC50, of 0.09 and 0.44 ng mL?1, respectively. Milk samples were spiked with standards equivalent to 0, 0.2, 0.3, 0.5, 1.0 &; 1.5 ng mL?1 and extracted in methanol. The mean recoveries were found to be 73–100% with coefficient of variance 7–11%. The decision limit (CCα) and detection capability (CCβ) were calculated as 0.10 and 0.12 ng mL?1, respectively. The results were found comparable with the commercial ELISA, having recoveries of 87 to 100%, CCα 0.09 ng mL?1 and CCβ 0.12 ng mL?1. As per Commission Decision 2002/657/EC, in-house ELISA was further validated by using LC-MS/MS. Mass spectral acquisition was done by using electrospray ionization in the negative ion mode applying single reaction monitoring of the diagnostic transition reaction for CAP (m/z 152, 194 and 257). The calibration curve showed good linearity in concentrations from 0.025 to 1.6 ng mL?1 with correction coefficient 0.9902. The mean recoveries were found to be 88 to 100%. The CCα was calculated as 0.057 ng mL?1 and CCβ 0.10 ng mL?1. Since CCα and CCβ are less than half of the MRPL (0.15 ng mL?1), the test was found suitable for screening and quantification of CAP residues in bovine milk samples. Results of surveillance studies indicated that out of 31 analyzed milk samples, 12.9% samples were found with CAP residues but only 3.2% samples were declared positive with maximum concentration 0.31 ng mL?1, slightly above the MRPL.
Keywords:Chloramphenicol  in-house ELISA  bovine milk  confirmation  mass spectrometry
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号