The “Mini Closed Pressure Vessel Test (MCPVT)” as a screening or classification test for explosive properties of organic peroxides
Authors:K D Wehrstedt  A Knorr  P Schuurman
Institution:

a Bundesanstalt für Materialforschung und -prüfung (BAM), Division II.2 “Reactive Substances and Systems”, Unter den Eichen 87, D-12205, Berlin, Germany

b Akzo Nobel Polymer Chemicals, Safety Services Deventer, Zutphenseweg 10, P.O. Box 10, 7400 AA, Deventer, The Netherlands

Abstract:Tests according to the UN Recommendations on the Transport of Dangerous Goods for the determination of explosive properties of organic peroxides have been compared with screening criteria for explosivity based on measurements in a closed mini-autoclave (MCPVT). It will be shown that an additional screening test may be helpful but the information obtained from the UN tests are more important to characterise the specific properties of a substance under different conditions.
Keywords:MCPVT  Organic peroxides  UN Manual of Tests and Criteria  Explosive properties