首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Design and startup of a membrane-biological-reactor system at a Ford-engine plant for treating oily wastewater.
Authors:B R Kim  J E Anderson  S A Mueller  W A Gaines  M J Szafranski  A L Bremmer  G J Yarema  C D Guciardo  S Linden  T E Doherty
Institution:Ford Research and Advanced Engineering, Dearborn, Michigan 48121, USA. bkim@ford.com
Abstract:A wastewater-treatment facility at Ford (Dearborn, Michigan) was recently upgraded from chemical de-emulsification to ultrafiltration (UF) followed by a membrane-biological reactor (MBR). This paper describes the design, startup, and initial operational performance of the facility. Primary findings are as follows: (1) the MBR proved resilient; (2) the MBR removed approximately 90% of chemical-oxygen demand (COD) after primary UF; (3) the removal of total Kjeldahl nitrogen by MBR appeared to be more sensitive to operating conditions than COD removal; (4) nitrification and denitrification were established in one month; (5) the MBR removed oil and grease and phenolics to below detection levels consistently, in contrast to widely fluctuating concentrations in the past; (6) permeate fluxes of the primary and MBR UF were adversely affected by inadvertent use of a silicone-based defoamer; and (7) zinc concentrations in the effluent increased, which might have been a result of ethylenediaminetetraacetic acid used in membrane washing solutions and/or might have been within typical concentration ranges.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏