首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Imposex was found in the Arctic whelk Buccinum finmarkianum at several marine stations off Thule Air Base, an US military facility in Northwest Greenland. This indicates a widespread contamination with the antifouling agents, tributyltin (TBT) or triphenyltin (TPhT) in the area, but such contamination was not supported by the organotin analyses in sediments, whelks and clams, which in general was below the analytical detection limit. Organotin concentrations above the detection limit were found only at one station close to a quay, where the highest frequency of imposex also occurred. This suggests that imposex in B. finmarkianum is a biomarker of TBT more sensitive than the detection limits, which the analytical chemistry could achieve in this study.  相似文献   

2.
Jiang JG  Shen YF 《Chemosphere》2007,68(4):637-646
In order to imitate the restoration succession process of natural water ecosystem, a laboratory microcosm system of constant-flow-restoration was designed and established. A eutrophycation lake, Lake Donghu, was selected as the subject investigated. Six sampling stations were set on the lake, among which the water of station IV was natural clean water, and others were polluted with different degrees. Polyurethane foam unit microbial communities, which had colonized in the stations for a month, were collected from these stations and placed in their respective microcosms, using clean water of station IV to gradually replace the water of these microcosms. In this process, the healthy community in clean water continuously replaced the damaged communities in polluted water, the restoration succession of the damaged communities was characterized by weekly determination of several functional and structural community parameters, including species number (S), diversity index (DI), community pollution value (CPV), heterotrophy index (HI), and similarity coefficient. Cluster analysis based on similarity coefficient was used to compare the succession discrepancies of these microbial communities from different stations. The ecological succession of microbial communities during restoration was investigated by the variable patterns of these parameters, and based on which, the restoration standards of these polluted stations were suggested in an ecological sense. That was, while being restored, the water of station 0 (supereutrophycation) should be substituted with natural clean water by 95%; station I (eutrophycation), more than 90%; station II (eutrophycation), more than 85%; station III (eutrophycation), about 85%; station V (mesoeutrophycation), less than 50%. The effects of the structural and functional parameters in monitoring and assessing ecological restoration are analyzed and compared.  相似文献   

3.
The objective was to investigate how tributyltin (TBT) contamination resulting from the establishment of a new marina and increasing yachting activities at Phuket Island, Thailand affects the area. A minimum of 30 specimen of the mangrove dwelling muricid Chicoreus capucinus were collected at five stations 2 months before and 5, 9, 18 and 33 months after Yacht Haven Marina was constructed. Imposex measured as RPLI and VDSI were significantly correlated to duration of time after construction and distance from the marina. All females developed imposex close to the marina after 18 months, whereas no significant increase occurred at stations more than 2 km from the marina. To evaluate the range of effects of the increasing yachting activities the muricid Thais distinguenda was used as an indicator of imposex at two popular mooring sites for yachts at Phi Phi and Raja Island in Phangna Bay, Thailand. The incidence of imposex was 100% at stations close to the mooring sites. A significant correlation existed between the distance from the sites and the incidence of imposex. The increasing incidence of imposex suggest that TBT contamination is worsening, against global trends, because regulations prohibiting the use of TBT-based paints, do not exist in Thailand.  相似文献   

4.
Two sampling campaigns have been carried out along the Sicilian coasts within the frame of a European project (Hic-TBT) financed by the LIFE programme. Snails and sediments have been sampled at 5 stations, characterised by very low (Ustica natural sea reserve), low (Ustica harbour), intermediate (Castellamare and Termini Imerese) and high shipping densities (Palermo). Biological and chemical analyses were carried out in order to evaluate the incidence of imposex occurring in snails, and the concentration levels of organotins in sediment and snail samples. Despite the low organotin concentration levels in sediment and snail samples, the results show that imposex is widespread around Sicily. In four locations almost all female snails were affected by imposex at advanced development stages, even in areas with a fairly low shipping density. Only in the natural sea reserve of Ustica Island imposex was relatively less severe. Finally a logarithmic correlation between TBT and imposex stages was observed.  相似文献   

5.
A critical problem arises if one attempts to compare data from air monitoring stations in different cities, because there are so many differences in monitoring site locations. Some air monitoring stations are on the 6 th and 8 th floors of tall buildings in downtown areas; some are at ground level beside streets with heavy traffic; some are in residential areas with little traffic or industry; and some are in suburban or nonurban areas. Unfortunately, there is ample evidence that the location of a monitoring station relative to nearby sources (such as highways) affects the values observed at the station, particularly for carbon monoxide and other vehicular pollutants. Thus, a standardized system of site selection, such as the one proposed here, appears essential to improve the comparability and meaningfulness of data obtained from different air monitoring stations throughout the Nation.  相似文献   

6.
Some preliminary analyses of data selected from three years of smoke shade and sulfur dioxide measurements from the forty air monitoring stations in New York City are presented. The purpose of these analyses is to investigate the spatial-temporal variation in concentration of these pollutants throughout the five boroughs of the city. Air pollution health effects studies in New York City have often used city-wide daily morbidity or mortality statistics and related them to air pollution levels obtained from a single monitoring station. The question of whether readings at one station in New York City can adequately represent the air pollution exposure for the population in the five boroughs is examined in this paper. Some samples of correlation matrices of daily pollution averages obtained from the forty air monitoring stations are presented to illustrate the day-to-day variation in pollution in various sections of New York City. It was found that interstation correlations are not high enough to justify the use of one central pollution measuring station as representative of a large metropolitan area. Sulfur dioxide correlates better between stations than smoke shade; this may reflect the different nature and spatial distribution of sources of the two pollutants. Close proximity of stations, or the fact that they were at similar heights above street or sea level did not necessarily lead to higher correlation coefficients.  相似文献   

7.
A new method was developed for determining the contribution of one pollutant source to the air quality in an industrialized region. Although the method is general, it is presented in reference to a 130,000 bbl/day petroleum refinery and its effect on ambient SO2 concentrations in Sarnia, Ontario. The plumes from SO2 emitters located upwind of the refinery were represented by a single hypothetical plume which influences monitoring stations located upwind as well as downwind from the refinery. However, the refinery emissions affect only the downwind stations. A simple equation was derived by means of which the concentration at the downwind station could be calculated from the concentration at the upwind station and the refinery emission. This equation contains two coefficients A and B which were evaluated such that the difference between the cumulative frequency distributions of the measured and calculated SO2 concentrations at the downwind station was minimized. For the meteorological conditions and monitoring stations considered, it was found that the refinery contributed less than 4.5 pphm to ambient SO2 concentrations over 1 hr periods. This result and the validity of the method are discussed.  相似文献   

8.
Aerosol black carbon (BC) mass concentrations ([BC]), measured continuously during a mutli-platform field experiment, Integrated Campaign for Aerosols gases and Radiation Budget (ICARB, March–May 2006), from a network of eight observatories spread over geographically distinct environments of India, (which included five mainland stations, one highland station, and two island stations (one each in Arabian Sea and Bay of Bengal)) are examined for their spatio-temporal characteristics. During the period of study, [BC] showed large variations across the country, with values ranging from 27 μg m?3 over industrial/urban locations to as low as 0.065 μg m?3 over the Arabian Sea. For all mainland stations, [BC] remained high compared to highland as well as island stations. Among the island stations, Port Blair (PBR) had higher concentration of BC, compared to Minicoy (MCY), implying more absorbing nature of Bay of Bengal aerosols than Arabian Sea. The highland station Nainital (NTL), in the central Himalayas, showed low values of [BC], comparable or even lower than that of the island station PBR, indicating the prevalence of cleaner environment over there. An examination of the changes in the mean temporal features, as the season advances from winter (December–February) to pre-monsoon (March–May), revealed that: (a) Diurnal variations were pronounced over all the mainland stations, with an afternoon low and a nighttime high; (b) At the islands, the diurnal variations, though resembled those over the mainlands, were less pronounced; and (c) In contrast to this, highland station showed an opposite pattern with an afternoon high and a late night or early morning low. The diurnal variations at all stations are mainly caused by the dynamics of local Atmospheric Boundary Layer (ABL). At the entire mainland as well as island stations (except HYD and DEL), [BC] showed a decreasing trend from January to May. This is attributed to the increased convective mixing and to the resulting enhanced vertical dispersal of species in the ABL. In addition, large short-period modulations were observed at DEL and HYD, which appeared to be episodic. An examination of this in the light of the MODIS-derived fire count data over India along with the back-trajectory analysis revealed that advection of BC from extensive forest fires and biomass-burning regions upwind were largely responsible for this episodic enhancement in BC at HYD and DEL.  相似文献   

9.
This paper describes a method to forecast the exceedance probability of a fixed threshold for a certain air pollutant concentration. This general approach has been applied in the case of carbon monoxide on 35 traffic monitoring stations in the Lombardy Region. The implemented model has been called FOREPOLL (Forecast Pollution).The model structure, consisting in three basic modules (the deterministic, the stochastic and the Bayesian one), has been thought to be adjustable to different stations of an air quality network and to various pollutants. Forepoll uses the last biennium data set of the station in exam (pollutants and micrometeorological parameters) as a moving learning time and also needs the forecasted synoptic weather type. In the first module the daily maxima of the hourly measured pollutant concentrations are checked in order to eliminate some known physical dependencies, such as the temperature dependence of the emissions. Then the data are divided into subgroups depending on the weather type and in each group fitted by a different Weibull distribution. To provide a first a priori exceedance probability, this distribution is daily rebuilt by taking into account the forecasted parameters. In the last module this probability is enhanced or reduced using simple, experience based, bayesian rules providing the a posteriori exceedance probability.Model validation trials have been carried out on a year of CO forecasted concentrations in different air quality stations; the first results are quite good particularly for the metropolitan areas, because the model seems to work better in case of stronger and more diffuse pollution.  相似文献   

10.
An air quality survey technique for measuring the horizontal spatial variation of carbon monoxide concentrations in urban areas is described; it was used to determine how representative an urban air monitoring station is of concentrations throughout the city.

The survey technique was applied in San Jose, Calif., where 1128 samples were collected over a six-month period and were compared with the values recorded simultaneously at the urban air monitoring station. All samples were collected at “breathing height” within a 13-square-mile grid which included the downtown area as well as surrounding residential and industrial locations. Three basic sampling strategies were employed to answer specific questions about the distribution of carbon monoxide concentration: (7) walking sampling, in which samples were obtained while walking along the sidewalks of congested downtown streets, (2) random spatial sampling, in which samples were collected at randomly selected points in the urban grid, and (3) specialized sampling in the immediate vicinity of the air monitoring station.

The results indicate that pedestrians on downtown streets in San Jose can be exposed to concentrations above the federal air quality standards without these values being observed at the air monitoring station. There also is evidence that, at any instant of time, similar values of carbon monoxide exist throughout this city (within a 13-square mile area), provided that measurements are not made in close proximity to streets. Furthermore, the higher concentrations observed in the immediate vicinity of streets decrease quite rapidly with increasing horizontal distance from these streets.

These findings, in the view of the authors, raise serious doubts as to whether it is possible to determine if air quality standards as currently defined are actually being met in urban areas using data from present-day air monitoring stations.  相似文献   

11.
The extent to which existing ozone monitoring data can be used to represent concentrations outside the area immediately surrounding a monitoring station is investigated. The results should be of Interest to those who wish to define areas within which standards are likely to have been exceeded. Relationships are established between the observed second-maximum hour-average ozone concentrations and the area within which It is possible to state with reasonable probability that National Ambient Air Quality Standards (NAAQS) have or have not been exceeded. All pairs of SAROAD stations (Storage and Retrieval of Aerometric Data) separated by 500 km or less which had nearly complete annual data sets were considered for the years 1974 through 1977 to determine the probability that the NAAQS would be exceeded at one station of the pair, given station separation and the observed second-maximum hourly ozone concentration at the other station. The resulting relationship was applied to SAROAD data for 1977, and circles were drawn around each SAROAD monitoring site to show the area within which it is 90% probable that the 120 ppb NAAQS was exceeded during 1977.  相似文献   

12.
Concerns about the levels of dust deposition in the vicinity of coal-fired power stations in North Yorkshire, in particular Drax Power Station, prompted the commissioning of a detailed monitoring study in the area. This paper describes the first two years' work. The first 12-month study concentrated on the village of Barlow close to Drax Power Station, whilst in the second 12-month study, monitoring sites were spread along a transect passing through the power station belt formed by Ferrybridge, Eggborough and Drax Power Stations. Two monitoring sites were common to both 12-month studies, thus giving two years of continuous monitoring. Pairs of wet Frisbee dust deposit gauges (based on inverted Frisbees) were located at each site. Undissolved particulate matter from each gauge was weighed and characterized by microscopic examination of individual particles. The first 12-month study revealed a downward gradient in dust deposition rate and cenosphere content with distance from Drax Power Station. The high cenosphere content at Barlow, especially at the eastern end, suggested that there was a significant contribution from coal-fired power stations. In the second year, the overall pattern of dust deposition rate and cenosphere content across the power station belt suggested that power stations were contributing to higher levels. In particular, relatively high levels were again found at Barlow. Wind direction correlations point to the fly-ash tip next to Drax Power Station as being the source of cenospheres arriving at Barlow. It is concluded that in both years the fly-ash tip Drax Power Station was making a significant contribution to higher than expected dust deposition rates at Barlow, particularly its eastern end. Other villages in the area may also have been affected by dust originating from coal-fired power stations.  相似文献   

13.
Weather and topographical situations where different types of emission sources give their highest ground level concentrations have been tabulated during a CORECH study. To see what daily average concentrations actually occur in an area where there are a large number of power stations, low level and other industrial sources but no topographical complications, occasions when one or more of the 10 SO2 recorders in the Drax monitoring network exceeded 200 μm−3 during the 10-year period preceding the termination of sampling were noted. There were 44 such occasions. On 17 of them, the principal contribution to the peak value appeared to come from low level sources associated with smoke emissions and on nine it appeared to come from industrial sources in the Doncaster (including Doncaster and Thorpe Marsh power stations), Scunthorpe (including Keadby power station) or Humberside (no power station) areas. The source areas containing the most modern 2000 MW power stations. South Yorkshire (13 times) and Trent Valley (five times), appeared to pre-dominale on other occasions. In these latter cases, with only one exception, the weather situation was either a persistent slow moving anti-cyclone with the free stream wind speed falling to 2.5 ms−1 or less or a day with a very steady free stream wind direction, associated with a col in the surface pressure distribution. In both of these situations, upward vertical mixing was limited by a subsidence and/or advection temperature inversion aloft.  相似文献   

14.
随着工业化、城镇化的深入推进,二氧化硫、氮氧化物、烟粉尘和挥发性有机物等各类污染物排放到环境中,致使中国大气受到严重污染,给人体的健康、动植物的生长、发育和繁殖等带来负面的影响。为实时监测环境空气质量,建立环境空气质量自动监测站逐渐成为大气污染防治的主要手段。文中以环境空气质量自动监测站为研究对象,提出环境空气质量自动监测站管理与维护面临的问题,探讨相应的解决措施,以期为环境空气质量自动监测站的管理与维护提供参考依据。  相似文献   

15.
This paper presents an objective methodology for determining the optimum number of ambient air quality stations in a monitoring network. The methodology integrates the multiple-criteria method with the spatial correlation technique. The pollutant concentration and population exposure data are used in this methodology in different ways. In the first stage, the Fuzzy Analytic Hierarchy Process (FAHP) with triangular fuzzy numbers (TFNs) is used to identify the most desirable monitoring locations. The network configuration is then determined on the basis of the concept of sphere of influences (SOIs). The SOIs are dictated by a predetermined cutoff value (rc) in the spatial correlation coefficients (r) between the pollutant concentrations at the monitoring stations identified from first step and the corresponding concentrations at neighboring locations in the region. Finally, the optimal station locations are ranked by using combined utility scores gained from the first and second steps. The expansion of air quality monitoring network of Riyadh city in Saudi Arabia is used as a case study to demonstrate the proposed methodology.  相似文献   

16.
以江阴市环境监测站标准化建设后评估工作为例,介绍了近年来苏南地区县级环境监测站的发展状况,指出了影响基层环境监测站发展的一些问题,并就相关对策进行探讨。  相似文献   

17.
This paper presents the hourly evolution of a severe Saharan dust outbreak, (SDO), affecting Central Spain over July 23-24, 2004 measured with a laser remote sensing device at a location close to the Guadarrama mountain range foothills and its impact on PM10 levels (particles with an aerodynamic diameter below 10 microm) recorded at four contrasting monitoring stations located in the upper and lower Spanish plateau, some 170km apart. During the period of study the Saharan dust layer, (SDL), presented significant hourly variability in height (3600-1500m), depth (1500-700m) and aerosol dust loading (extinction coefficient, EC, 0.22-1.28km(-1)). Overnight layering was generally observed whereas a well mixed layer prevailed in the afternoon. The (SDO) impact on the lower levels took place approximately 12h after the (SDL) was initially observed and triggered by a descending dust enriched, evidencing the important role of subsidence over the presence of dust in lower altitudes. During the event, PM10 levels at all the stations exceeded EU air quality daily mean standards, 50 microgm(-3), on 2-4days. The maximum values ranged from 185 to 245 microgm(-3) depending on the monitoring station. The impact on PM10 spread from 2days in the upper plateau to 3-4 in the lower plateau, in agreement with the geographical location of the monitoring stations with respect to the southwest origin of the intrusion. The impact was even more dramatic on PM10 hourly concentrations, leading to maximum hourly peaks ranging from 322 to 598 microgm(-3) again depending on the monitoring station. Correlations between EC vertical profiles and PM10 hourly concentrations at the monitoring stations showed the great influence of the (SDO) on surface concentrations. The best linear fits corresponded to the extinction coefficients in the lower altitudes (close to the lower range of the device 500-650m), EC2, yielding satisfactory correlation coefficients ranging from 0.68 to 0.71. The low variability of the slope of each individual linear fit, 19.2%, shows the similar impact of (SDO) on the PM10 hourly concentrations recorded in the area under study.  相似文献   

18.
Mexico has a very important oil industry, comprehending the exploration, production, transformation, storage and distribution of crude oil and its fractions. Petroleos Mexicanos (PEMEX) is a state-owned monopoly in charge of these activities. Oil and oil-products transport is an extremely crucial operation for the cycle production-transformation-distribution. Pipeline system transport crude oil and sub-products along the country (including liquids, gases and mixtures). It has been reported that more than 30% of the oil ducts in Mexico have been operating for over 30 years, although their lifetime has been calculated in 25-30 years. This work is aimed at characterizing a zone around six oil-pipeline pumping stations located at northern Mexico. The specific places to evaluate soil contamination were (1) the distribution head of the Gomez Palacio (GOPA) pumping station; (2) the north side of the old ditch, the API oil separator and the wastewater zones of the Jimenez (JIM) pumping station; (3) the pumping stations of Ceballos (CE), Peronal (PER), Simon Bolivar (SIBO), and Mayran (MAY). The study comprehended sampling of the areas, delimitation of contamination in the vertical and horizontal extension, analysis of the sampled soils, regarding TPH and, in some cases, the 16 PAHs considered as a priority by USEPA, calculation of areas and volumes contaminated (according to the Mexican legislation, specifically NOM-EM-138-ECOL-2002) and, finally, a proposal for the best remediation techniques suitable for the encountered contamination levels and the localization of contaminants. In general, TPHs were found in all the pumping stations analyzed in this study. Regarding maximal TPHs concentrations at the stations, their order of contamination was as follows: SIBO>CE>PER>MAY>JIM>GOPA. PAHs were found only in a few points at concentrations above the detection limit. At the Jimenez, Gomez Palacio, Peronal, and Ceballos stations, only one point, with PAHs values over the detection limit was found, whereas two points were found at Mayran, and finally at the Simon Bolivar station there were four points with measurable amounts of PAHs. Given the areas and volumes that need to be treated (32835 m3), as well as the physical position of contaminants, it is considered that excavation of the contaminated soil is feasible and the cleaning process could be soil washing assisted with surfactants, though bioremediation should not been discharged as a possible remediation technique.  相似文献   

19.
ABSTRACT

We measured particulate matter (PM2.5 and PM10) exposures, home temperature, arterial blood oxygen saturation, blood pressure, and lung function in 30 volunteer Los Angeles area residents during four-day intervals. Continuous Holter electrocardiograms were recorded in a subgroup on the first two days. Subjects recorded symptoms and time-activity patterns in diaries during monitoring, and during a reference period one week earlier/later. All subjects had severe chronic obstructive pulmonary disease. PM10 (24-hr mean) at monitoring stations near subjects’ homes averaged 33 μg/m3, and ranged from 9 to 84 μpg/m3. In longitudinal analyses, day-to-day changes in PM2.5 and PM10 outside subjects’ homes significantly tracked concurrent station PM10 (r2 = 0.22 and 0.44, respectively). Indoor and personal concentrations were less related to station readings (r2 ≤ 0.1), but tracked each other (r2 ≥ 0.4). In-home temperatures tracked outdoor temperatures more for lows (r2 = 0.27) than for highs (r2 = 0.10). These longitudinal relationships of subject-oriented and station PM measurements were generally similar to cross-sectional relationships observed previously in similar subjects. Among health measurements, only blood pressure showed reasonably consistent unfavorable longitudinal associations with particulates, more with station or outdoor PM than with indoor or personal PM.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号