Data from ten years of integrated monitoring were used here to evaluate whether pine needles are a feasible tool for an assessment of long-term trends of the atmospheric contamination. Pine needles collected once a year were compared to high volume air samples collected for 24 h, every 7 days, and passive air samples integrated over 28-day periods. Results showed the same concentration patterns of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) captured in needles and high volume samples. Passive air samplers were less efficient in sampling the particle-bound compounds. Theoretical air volume equivalent to each needle sample (VEQ) was calculated as a ratio of the needle concentration over the mean air concentration. Results indicated different equivalent volumes for PAHs and organochlorines, possibly due to the faster degradation rates of PAHs in needles. The most important finding is that in the long term a needle monitoring gives very similar information on temporal trends of the atmospheric pollution as does a high volume air monitoring.  相似文献   

2.
Orliński R 《Chemosphere》2002,48(2):181-186
Polycyclic aromatic hydrocarbons (PAHs) distribution along 28 km of Warsaw main street have been surveyed in July 2000 using moss passive samplers as a simple and economic surrogate of direct air sampling. Altogether 74 samplers at 39 crossroads with traffic lights were placed on the lamp post approximately/=3.5 m above ground. PAHs levels determined in samplers are in range from 828 to 3573 ng/g moss dry weight. The spatial spread of pollution within this range is statistically close to normal distribution with mean value of 2332 ng/g. Variability within and between study areas are rationalized in terms of urban environmental factors. PAHs concentrations profiles across the town have appeared uniform. The dominant compounds are phenantrene, fluoranthene and pyrene. Their contribution is 49-68% of total PAHs burden.  相似文献   

3.
T Hamers  M G Smit  A J Murk  J H Koeman 《Chemosphere》2001,45(4-5):609-624
A newly developed method for measuring the integrated esterase inhibiting potency of rainwater samples was applied in practice, and the results are compared to the toxic potency calculated from concentrations of 31 organophosphate (OP) and carbamate pesticides, out of a total of 66 chemically analyzed pesticides. In addition, the general toxic potency of the rainwater samples was evaluated in a microtiter luminescence assay with Vibrio fischeri bacteria. Rainwater samples were collected over four consecutive 14-day periods in both open and wet-only samplers. The esterase inhibiting potency of the open rainwater samples (expressed as ng dichlorvos-equivalents/l) corresponded well with the chemical analyses of the rainwater samples collected by both types of samplers (r = 0.83-0.86). By far, the highest esterase inhibiting potency was found in a sample collected in an area with intense horticultural activities in June, and was attributed to high concentrations of dichlorvos, mevinphos, pirimiphos-methyl and methiocarb. The esterase inhibiting potency of this sample was equivalent to a dichlorvos concentration of 1380 ng/l in the rainwater, which is almost 2000 times higher than the maximum permissible concentration (MPC) of dichlorvos set for surface water in Netherlands. Maximum individual concentrations of dichlorvos and pirimiphos-methyl even exceeded the EC50 for Daphnia, suggesting that pesticides in rainwater pose a risk for aquatic organisms. Not all responses of the luminescence-assay for general toxicity could be explained by the analyzed pesticide concentrations. The bio-assays enable a direct assessment the toxic potency of all individual compounds present in the complex mixture of rainwater pollutants, even if they are unknown or present at concentrations below the detection limit. Therefore, they are valuable tools for prescreening and hazard characterization purposes.  相似文献   

4.
Gaseous emissions of combusted electronic scrap, PVC, carpet and wood were monitored for polycyclic aromatic hydrocarbons (PAHs) by simultaneous use of semipermeable membrane devices (SPMDs) and shoots of spruce needles (Picea abies). It was found that phenanthrene, acenaphthylene and fluorene were the dominating PAHs in all samples. SPMDs and needles mainly sequestered PAH associated with the vapor phase. Particle-bound PAHs were only detected in small amounts, at which the needles tended to uptake more of these compounds in comparison to the SPMDs. Nevertheless, the logarithm of the concentrations of PAHs analyzed in both passive samplers after the same sampling period exhibited a significant linear correlation with correlation coefficients larger than 0.8073. SPMDs and spruce needles can complement each other in passive air sampling for compounds with a preference to the gas phase rather than aerosols.  相似文献   

5.
Triolein-containing semipermeable membrane devices (SPMDs) were employed as passive samplers to provide data on the bioavailable fraction of organic, waterborne, organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polynuclear aromatic hydrocarbons (PAHs) in streams flowing through a highly polluted industrial area of Bitterfeld in Saxony-Anhalt, Germany. The contamination of the region with organic pollutants originates in wastewater effluents from the chemical industry, from over one-hundred years of lignite exploitation, and from chemical waste dumps. The main objective was to characterise time-integrated levels of dissolved contaminants, to use them for identification of spatial trends of contamination, and their relationship to potential pollution sources. SPMDs were deployed for 43 days in the summer of 1998 at four sampling sites. The total concentration of pollutants at sampling sites was found to range from a low of 0.8 microgram/SPMD to 25 micrograms/SPMD for PAHs, and from 0.4 microgram/SPMD to 22 micrograms/SPMD for OCPs, respectively. None of the selected PCB congeners was present at quantifiable levels at any sampling site. A point source of water pollution with OCPs and PAHs was identified in the river system considering the total contaminant concentrations and the distribution of individual compounds accumulated by SPMDs at different sampling sites. SPMD-data was also used to estimate average ambient water concentrations of the contaminants at each field site and compared with concentrations measured in bulk water extracts. The truly dissolved or bioavailable portion of contaminants at different sampling sites ranged from 4% to 86% for the PAHs, and from 8% to 18% for the OCPs included in the estimation. The fraction of individual compounds found in the freely dissolved form can be attributed to the range of their hydrophobicity. In comparison with liquid/liquid extraction of water samples, the SPMD method is more suitable for an assessment of the background concentrations of hydrophobic organic contaminants because of substantially lower method quantification limits. Moreover, contaminant residues sequestered by the SPMDs represent an estimation of the dissolved or readily bioavailable concentration of hydrophobic contaminants in water, which is not provided by most analytical approaches.  相似文献   

6.
The potential of passive air sampling devices (polyurethane foam disks) to assess the influence of local sources on the quality of the surrounding environment was investigated. DEZA Valasske Mezirici, a coal tar and mixed tar oils processing plant, and Spolana Neratovice, a chemical factory with the history of high production of organochlorinated pesticides (OCPs), were selected as the point sources of PAHs, and OCPs, respectively. Levels of PCBs, OCPs and PAHs were determined for all sampling sites and sampling periods. The study brought useful data about the air concentrations of POPs in the investigated regions. More important, it provided information on the transport and fate of POPs in the vicinity of local sources of contamination useful for the estimation of their influence. Very good capability of passive samplers to reflect temporal and spatial fluctuation in concentrations of persistent organic pollutants in the ambient air was confirmed which makes them applicable for monitoring on the local scale.  相似文献   

7.
In this study the levels and distribution of some persistent toxic substances (PTS) were investigated in soils, superficial water, and snow along an altitudinal gradient in the Laja River Basin (South Central Chile). The principal objective was to establish the basin's contamination status. The working hypothesis was that PTS levels and distribution in the basin are dependent on the degree of anthropogenic intervention. Fifteen PAHs, seven PCBs congeners, and three organochlorine pesticides were studied in superficial soil and water samples obtained along the altitudinal gradient and from a coastal reference station (Lleu-Lleu River). Soil samples were extracted using accelerated solvent extraction with acetone/cyclohexane (1:1) for PAHs and organochlorine compounds. Contaminants were extracted from water and snow samples by liquid-liquid extraction (LLE). PAH and organochlorine compound quantification was carried out by HPLC with fluorescence detection and GC-MS, respectively. PCBs in soils presented four different profiles in the altitudinal gradient, mainly determined by their chlorination degree; these profiles were not observed for the chlorinated pesticides. In general, the detected levels for the analyzed compounds were low for soils when compared with soil data from other remote areas of the world. Higher summation operator PAHs levels in soils were found in the station located at 227 masl (4243 ng g-1 TOC), in a forestry area and near a timber industry, where detected levels were up to eight times higher than the other sampling sites. In general, PAH levels and distribution seems to be dependent on local conditions. No pesticides were detected in surface waters. However, congeners of PCBs were detected in almost all sampling stations with the highest levels being found in Laja Lake waters, where 1.1 ng/l were observed. This concentration is two times higher than values reported for polluted lakes in the Northern Hemisphere. The presence of organochlorine compound in snow sampled at the highest elevation point of the basin is indicative of the transport and atmospheric deposition phenomena of alpha-HCH, gamma-HCH and PCB 52, with values being similar to the levels reported in Canadian snow samples. We conclude that environmental PTS substance levels are in general relatively low, although PAHs may be of concern in some areas of the basin.  相似文献   

8.
A fine particulate matter (PM2.5) sampling program was conducted in Missoula, MT, to investigate both the particle and vapor phases of PM2.5-associated polycyclic aromatic hydrocarbons (PAHs) found in a northern Rocky Mountain urban airshed. Twenty-four-hour samples were collected during the cold winter months of January through April 2002, when many of the more volatile organic components of PM2.5 were expected to be found in the condensed particle form. To meet analytical detection limits, each of the 12 individual sample days were aggregated into four total filter and polyurethane foam (PUF) samples, respectively, with each aggregate containing 3 sample days. Quartz filter (particle-phase PAHs) and PUF (vapor-phase PAHs) aggregates were analyzed separately for 18 individual PAHs and phenolics by gas chromatography/mass spectrometry. Results showed that 87% of the PM2.5-associated phenolics and PAHs measured in this study were found in the vapor phase. PM2.5-associated gas/particle partition coefficients (Kp,2.5) ranged from 0 for the lighter phenolics and PAHs to approximately 0.1 for some of the heavier PAHs, such as fluoranthene and pyrene. Calculating Kp,2.5 for the heaviest measured PAHs was not feasible because of low or undetectable concentrations in the vapor phases of these compounds. Phenolics and two-ringed and three-ringed PAHs were found almost exclusively in the vapor phase. Four-ringed PAHs were distributed between the particle and vapor phases, with more mass measured in the vapor phase. Very little five-ringed and higher PAHs were measured from either the filter or PUF sampling medium. These results provide information on both the concentrations and different phases of PM2.5-associated PAHs measured during the winter months in a northern Rocky Mountain urban airshed, when concentrations of PM2.5 are generally at their highest compared with the rest of the year.  相似文献   

9.
本文比较系统地讨论了空气中多环芳烃(PAHs)的研究现状。重点介绍了空气颗粒物及气相中多环芳烃的采样分析新办法,城市大气及居民室内外空气中多环芳烃的污染状况及其来源,简单介绍了人体接触多环芳烃的水平,指标及空气中多环芳烃的健康风险评价的研究概况。共引文献129篇。  相似文献   

10.
ABSTRACT

A multi-system, high-volume, parallel plate diffusion dénuder Brigham Young University Organic Sampling System (BIG BOSS) was tested using collocated samplers at the Pico Rivera Monitoring Station of the South Coast Air Quality Management District, South Coast Air Basin, in September 1994. Six-hr daytime and 9-hr nighttime samples were collected with a flow of about 200 L/min through each of the three systems designed to collect particles smaller than 2.5, 0.8, and 0.4 mm in a diffusion denuder sampler. Efficiency for the removal of gas phase organic compounds by the diffusion denuder was evaluated using both theoretical predictions and field measurements. Both measured and calculated data indicate high denuder efficiency for the removal of gas phase aromatic and paraffinic compounds. The precision of the BIG BOSS was evaluated using collocated samplers. The precision of determination of total carbon and elemental carbon retained by a quartz filter or of semi-volatile carbonaceous material lost from particles during sampling averaged ±7%. The precision of determination of individual organic compounds averaged ±10%. An average of 42 and 62% of the particulate organic material was semi-volatile organic compounds (SVOCs) lost from particles during sampling for daytime and nighttime samples, respectively. This “negative” sampling artifact was an order of magnitude larger than the “positive” quartz filter artifact due to adsorption of gas phase organic material. Daytime concentrations of fine particulate elemental carbon and nonvolatile organic carbon were higher than nighttime concentrations, but nighttime fine particles contained more semi-volatile organic material than daytime.  相似文献   

11.
Membrane-enclosed copolymer (MECOPs) samplers containing crystalline copolymers of ethylvinylbenzene-divinylbenzene in polyethylene membranes were used to assess the influence of a steel complex on the level and spatial distribution of polycyclic aromatic hydrocarbons (PAHs) in ambient air. MECOPs were deployed at six sites in Pohang, Korea for 37 days (August 9, 2005–September 14, 2005). Fluorene, phenanthrene, anthracene, and fluoranthene were dominant PAHs with the highest contribution of phenanthrene (59%) to the total amount of vapor-phase PAHs. The spatial distribution of total PAHs in the vapor phase ranging from 76 to 1077 ng MECOP−1 and air dispersion modeling suggested that the steel complex was the major PAH source in Pohang. It was revealed that the major wind directions rather than the distance from the steel complex were a significant factor affecting the levels of PAHs at the sampling sites. Finally, we tried to convert MECOP concentrations (ng MECOP−1) to air concentrations (ng m−3) with the modified sampling rates (m3 day−1). This study demonstrates again that passive air samplers are useful tools for spatially resolved and time-integrated monitoring of semivolatile organic compounds (SOCs) in ambient air.  相似文献   

12.
Vertical snow sampling and moss bag transplants were used to estimate the local inorganic and organic pollutant load deposited from traffic along a major highway in Finland. The pH and concentrations of Cl(-), NO(3)(-), SO(4)(2-), Ca(2+), Na(+) and polyaromatic hydrocarbons (PAHs) were determined from snow samples collected in winter at different sites along the highway. In summer, moss bags containing 20 g of fresh red-stemmed feather moss (Pleurozium schreberi) were transplanted at the same sites. The moss bag transplants remained exposed to roadside traffic for a period of one month following which the samples were collected and the PAH profiles and concentrations were analysed. The deposition of inorganic and organic pollutants from road traffic was observed up to 60 m from the road. The prevailing winds had a significant effect on the dispersion of pollutants. Snow appears to be a good collector of inorganic pollutants from the atmosphere and can be used to monitor local airborne pollution from road traffic. Snow packs can also be used as passive collectors of organic pollutant loads from road traffic on a local scale. To monitor organic PAH deposition from the road traffic, moss bags appeared to be better indicators compared to snow sampling. The efficiency of moss bags in accumulating PAH compounds indicate that vegetation may be an important sink for traffic pollution.  相似文献   

13.
Passive samplers with polyurethane disks (PUF) were applied in the determination of the concentration of polycyclic aromatic hydrocarbons (PAHs) in ambient air in six residential areas in the Philippines during four simultaneous sampling periods. The uptake profiles of PAHs were determined at one site during one sampling period. Most of the PAHs that were detected in air at concentrations that were significantly higher than their analytical detection limits exhibited a linear uptake trend on the PUF disk. The linear uptake profiles of some high molecular weight (HMW) PAHs were not established and this is attributed to the low concentration of the compounds in air in the gaseous phase. The retention concentrations of phenanthrene-d-10 were determined after depuration in four sampling sites during two sampling periods. The sampling rate for phenanthrene-d-10 was calculated at the linear phase of the uptake using the kA derived from depuration experiments and the relationship of kA and sampling rate which was established in a previous passive sampling study. The average sampling rate obtained for phenanthrene d-10 (2.94±0.69 m3 d−1) was applied for derivation of the concentrations of the PAHs in the field samples.The passive sampler with PUF disk and short integration time of 42–56 days is applicable for the derivation of the concentrations of PAHs in ambient air in the Philippines. The concentrations of the organic pollutants derived from the passive sampler showed variability for the six residential areas; reflecting the influence of possible sources of emission of the pollutants at the sites at the different sampling periods. The weather conditions, including the occurrence of a tropical cyclone, increased rainfall and high-relative humidity during the rainy season, had an influence on the concentrations of PAHs derived by the passive sampler.  相似文献   

14.
XAD-2 resin-based passive samplers (PAS) with dimensions adapted to 100 mL accelerated solvent extraction cells were used to study the temporal and spatial variations of 17 PAHs on five sites in the atmosphere of southern Luxembourg. This new design allowed extracting the PAS without emptying the resin from the shelter. PAH analyses were done with gas chromatography–tandem mass spectrometry. PAS were deployed for 1 year with varying sampling periodicities, and 16 PAHs were detected with concentrations ranging from 1 ng/PAS for chrysene to 9,727 ng/PAS for naphthalene. The PAS were found adapted to the monitoring of temporal and spatial variations for lightweight PAHs (up to four aromatic rings) though not for heavy PAHs with five aromatic rings or more, as these compounds are preferably in the particle phase of the atmosphere and the amount of these PAHs trapped on the PAS will be too low.  相似文献   

15.
Polar organic chemical integrative samplers (POCIS) are useful for monitoring a wide range of chemicals, including polar pesticides, in water bodies. However, few calibration data are available, which limits the use of these samplers for time-weighted average concentration measurements in an aquatic medium. This work deals with the laboratory calibration of the pharmaceutical configuration of a polar organic chemical integrative sampler (pharm-POCIS) for calculating the sampling rates of 17 polar pesticides (1.15?≤?logK ow?≤?3.71) commonly found in water. The experiment, conducted for 21 days in a continuous water flow-through exposure system, showed an integrative accumulation of all studied pesticides for 15 days. Three compounds (metalaxyl, azoxystrobine, and terbuthylazine) remained integrative for the 21-day experiment. The sampling rates measured ranged from 67.9 to 279 mL?day?1 and increased with the hydrophobicity of the pesticides until reaching a plateau where no significant variation in sampling rate is observed when increasing the hydrophobicity.  相似文献   

16.
The University of Arizona and the Pima County Air Pollution Control District conducted a comparison study of the following aerosol samplers: a standard high-volume sampler, a high-volume sampler fitted with a size selective inlet, and a dichotomous virtual impactor. Over sixty samples were collected with the colocated samplers during the first six months of 1981. The concentration (μg/m3) of suspended particulate matter and of sulfate was determined for all the samples, while the concentration of four lithophilic elements (Ca, Fe, Mg, and K) was determined on one third of the samples. Well-defined linear relationships for suspended particulate matter and sulfate were found to exist between each of the three sample collection methods over the concentrafion range encountered in this study. For these samples, there were significant differences in the particulate mass and large particle lithophilic element concentrations collected by each device. However, sulfate values obtained from the three samplers were in excellent agreement with each other. This suggests that the inlet collection efficiency for large particles differs significantly for these three sampling devices. Since the size selective inlet and the dichotomous virtual impactor samplers are each designed for collection of inhalable particles (particles of 15 μm aerodynamic diameter and smaller), they would have been expected to measure approximately equivalent particle mass concentrations. Thus, these differences are important to those interested in selecting a method for measuring airborne particle mass concentrations.  相似文献   

17.
XAD-2® passive samplers (PAS) have been exposed simultaneously for 14 days on two sites, one rural and one urban, situated in Alsace (East of France) during intensive pesticides application in agriculture (between March and September). PAS have been extracted and analyzed for current-used pesticides and lindane with an analytical method coupling accelerated solvent extraction (ASE), solid-phase microextraction (SPME) and GC/MS/MS. Results show the detection of pesticides is linked to the period of application and spatial and temporal variabilities can be observed with these PAS during the selected sampling period. The spatial and temporal variability is comparable to the one previously observed by comparing data obtained with PAS with data from Hi.-Vol. samplers in an urban area. Sampling rates were calculated for some pesticides and values are comparable to the data already available in the literature. From these sampling rates, concentrations in ng m?3 of pesticides in PAS have been calculated and are in the same order of magnitude as those obtained with Hi.Vol. sampling during the same period of time.  相似文献   

18.
The capability of passive air sampling to be employed in the evaluation of direct genotoxicity of ambient air samples was assessed. Genotoxic effects of the total extracts from the polyurethane foam filters exposed for 28 days during a regional passive air sampling campaign were investigated. Twenty sampling sites were selected in Brno city on the area of approximately 20x20 km in October and November 2004. Brno is the second largest city of the Czech Republic, highly industrialized with approximately 370,000 of permanent inhabitants. The levels of PAHs, PCBs, and chlorinated pesticides were determined in all samples. Fraction of each extract was also assayed in the bacterial genotoxicity test using Escherichia coli sulA::lacZ. Complete dose-response relationships of the air extracts were determined. The statistical analysis showed significant correlation between observed biological effects and PAHs concentrations in samples.  相似文献   

19.
The precision and accuracy of the determination of particu-late sulfate and fluoride, and gas phase SO2 and HF are estimated from the results obtained from collocated replicate samples and from collocated comparison samples for high-and low-volume filter pack and annular diffusion denuder samplers. The results of replicate analysis of collocated samples and replicate analyses of a given sample for the determination of spherical aluminosilicate fly ash particles have also been compared. Each of these species is being used in the chemical mass balance source apportionment of sulfur oxides in the Grand Canyon region as part of Project MOHAVE, and the precision and accuracy analyses given in this paper provide input to that analysis. The precision of the various measurements reported here is ±1.8 nmol/m3 and ±2.5 nmol/m3 for the determination of SO2 and sulfate, respectively, with an annular denuder. The precision is ±0.5 nmol/m3 and ±2.0 nmol/m3 for the determination of the same species with a high-volume or low-volume filter pack. The precision for the determination of the sum of HF(g) and fine particulate fluoride is ±0.3 nmol/m3. The precision for the determination of aluminosilicate fly ash particles is ±100 particles/m3. At high concentrations of the various species, reproducibility of the various measurements is ±10% to ±14% of the measured concentration. The concentrations of sulfate determined using filter pack samplers are frequently higher than those determined using diffusion denuder sampling systems. The magnitude of the difference (e.g., 2-10 nmol sulfate/m3) is small, but important relative to the precision of the data and the concentrations of particulate sul-fate present (typically 5-20 nmol sulfate/m3). The concentrations of SO2(g) determined using a high-volume cascade impactor filter pack sampler are correspondingly lower than those obtained with diffusion denuder samplers. The concentrations of SOx (SO2(g) plus particulate sulfate) determined using the two samplers during Project MOHAVE at the Spirit Mountain, NV, and Hopi Point, AZ, sampling sites were in agreement. However, for samples collected at Painted Desert, AZ, and Meadview, AZ, the concentrations of SOx and SO2(g) determined with a high-volume cascade impactor filter pack sampler were frequently lower than those determined using a diffusion denuder sampling system. These two sites had very low ambient relative humidity, an average of 25%. Possible causes of observed differences in the SO2(g) and sulfate results obtained from different types of samplers are given.  相似文献   

20.
Air samples of particulate matter (PM) with an aerodynamic diameter less than 10 microm (PM10) were collected from six sites in Bangkok, Thailand, using high-volume air samplers. Daily samples were taken at intervals of 12 days from November 1999 to November 2000. Size-selected sampling using a multislit Andersen size-fractionated cascade impactor was undertaken at one site in central Bangkok to identify particulate size distribution. The annual average PM10 concentration at all six sites exceeded the Thailand National Ambient Air Quality Standard (NAAQS) of 50 microg/m3. The daily PM10 concentrations at heavy traffic roadside areas ranged between 30 and 160 microg/m3. The highest PM10 level occurred during the winter period (November-February), which is the dry season. From our results, which are based on a 1-yr survey, it can be observed that the particulate concentrations are associated with traffic volumes and seasonal factors (temperature and rainfall). The relative importance of size fractions in contributing to PM load is presented and discussed. Twenty polycyclic aromatic hydrocarbons (PAHs) associated with PM have been identified and quantified. The summed PAHs based on the 20 species had an average concentration of 60 ng/m3. Benzo(e)pyrene, indeno(123cd)pyrene, and benzo(ghi)perylene were the major compounds with average concentrations of 8, 10, and 13 ng/m3, respectively. Results indicate that more than 97% of PAHs were found in the small particulate size range of <0.95 microm.  相似文献   