首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
A new spectrophotometric method is reported for the determination of nanomolar level of malachite green in surface water samples. The method is based on the catalytic effect of silver nanoparticles on the oxidation of malachite green by hexacyanoferrate (III) in acetate–acetic acid medium. The absorbance is measured at 610 nm with the fixed-time method. Under the optimum conditions, the linear range was 8.0?×?10?9–2.0?×?10?7?mol?L?1 malachite green with a correlation coefficient of 0.996. The limit of detection (S/N?=?3) was 2.0?×?10?9?mol?L?1. Relative standard deviation for ten replicate determinations of 1.0?×?10?8?mol?L?1 malachite green was 1.86 %. The method is featured with good accuracy and reproducibility for malachite green determination in surface water samples without any pre-concentration and separation step.  相似文献   

2.
The present study reports on the application of modified groundnut shell as a new, easily prepared, and stable sorbent for the extraction of trace amount of Cr(III) in aqueous solution. 2-Hydroxybenzaldiminoglycine was immobilized on groundnut shells in alkaline medium and then used as a solid phase for the column preconcentration of Cr(III). The elution was carried out with 3 mL of 2 mol?L?1 HCl. The amount of eluted Cr(III) was determined by spectrophotometry using cefaclor as a complexing reagent and by flame atomic absorption spectrometry (FAAS). Different experimental variables such as pH, amount of solid sorbent, volume and concentration of eluent, sample and eluent flow rate, and interference of other metal ions on the retention of Cr(III) were studied. Under the optimized conditions, the calibration curves were found to be linear over the concentration range of 13–104 and 10–75 μg?L?1 with a detection limit of 3.64 and 1.24 μg?L?1 for spectrophotometric method and FAAS, respectively. An enrichment factor of 200 and RSD of ±1.19–1.49 % for five successive determinations of 25 μg?L?1 were achieved. The column preconcentration was successfully applied to the analysis of tap water and underground water samples.  相似文献   

3.
In this work, spectrophotometer was used as a detector for the determination of uranium from water, biological, and ore samples with a flow injection system coupled with solid phase extraction. In order to promote the online preconcentration of uranium, a minicolumn packed with XAD-4 resin impregnated with nalidixic acid was utilized. The system operation was based on U(VI) ion retention at pH 6 in the minicolumn at flow rate of 15.2 mL min?1. The uranium complex was removed from the resin by 0.1 mol dm?3 HCl at flow rate of 3.2 mL min?1 and was mixed with arsenazo III solution (0.05 % solution in 0.1 mol dm?3 HCl, 3.2 mL min?1) and driven to flow through cell of spectrophotometer where its absorbance was measured at 651 nm. The influence of chemical (pH and HCl (as eluent and reagent medium) concentration) and flow (sample and eluent flow rate and preconcentration time) parameters that could affect the performance of the system as well as the possible interferents was investigated. At the optimum conditions for 60 s preconcentration time (15.2 mL of sample volume), the method presented a detection limit of 1.1 μg L?1, a relative standard deviation (RSD) of 0.8 % at 100 μg L?1, enrichment factor of 30, and a sample throughput of 42 h?1, whereas for 300 s of the preconcentration time (76 mL of sample volume), a detection limit of 0.22 μg L?1, a RSD of 1.32 % at 10 μg L?1, enrichment factor of 150, and a sampling frequency of 11 h?1 were reported.  相似文献   

4.
A colorimetric assay method is described for the environmental detection of 2-mercaptobenzimidazole (MBI) using surface plasmon resonance of gold nanoparticles (AuNPs). Stable and dispersed AuNPs with intensified plasmon resonance were prepared in situ using a simple, rapid, and eco-friendly procedure by applying ascorbic acid as a reducer and cetyltrimethylammonium bromide as a stabilizer. The presence of MBI has a strong effect on the plasmon absorbance of AuNPs, which was employed for the detection of MBI. The calibration curve was linear in the range of 1.0?×?10?6–5.5?×?10?5 mol/L of MBI; the detection limit was 8.4?×?10?7 mol/L. The relative standard deviations for eight replicate measurements of 3.0?×?10?6 and 5?×?10?5 mol/L MBI were 3.9 and 1.4 %, respectively. The method was successfully applied to the determination of MBI in tap, river, sea, and heat exchanger cooling water samples.  相似文献   

5.
The developed method is based on cold-induced aggregation microextraction of Se(IV) using the 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid as an extractant followed by spectrophotometry determination. The extraction of Se(IV) was performed in the presence of dithizone as the complexing agent. In this method, a very small amount of 1-butyl-3-methylimidazolium hexafluorophosphate was added to the sample solution containing Se-dithizone complex. Then, the solution was kept in a thermostated bath at 50 °C for 4 min. Subsequently, the solution was cooled in an ice bath and a cloudy solution was formed. After centrifuging, the extractant phase was analyzed using a spectrophotometric detection method. Some important parameters that might affect the extraction efficiency were optimized (HCl, 0.6 mol L?1; dithizone, 4.0?×?10?6 mol L?1; ionic liquid, 100 μL). Under the optimum conditions, good linear relationship, sensitivity, and reproducibility were obtained. The limit of detection (LOD) (3Sb/m) was 1.5 μg L?1, and the relative standard deviation (RSD) was 1.2 % for 30 μg L?1 of Se(IV). The linear range was obtained in the range of 5–60 μg L?1. It was satisfactory to analyze rice and various water samples.  相似文献   

6.
In this study, an ultra-sensitive and highly selective, rapid flow-injection spectrophotometric method for the determination of iron (II) and total iron has been proposed. The method was based on the reaction between iron (II) and 2′, 3, 4′, 5, 7-pentahydroxyflavone in slightly acidic solution with a strong absorption at 415 nm. The carrier solution used was 1?×?10?5 M 2′, 3, 4′, 5, 7-pentahydroxyflavone in 0.1 M HAc/Ac? buffer solution at pH 4.5. Parameters that affect simultaneously the determination of iron (II) and interfering ions were tested. The relative standard deviation for the determination of 50 μg L?1 iron (II) was 0.85 % (n?=?10), and the limit of detection (blank signal plus three times the standard deviation of the blank) was 3 μg L?1, both based on injection volumes of 20 μL. The method has been successfully applied to the determination of iron (II) and total iron in water samples and ore samples. The method was verified by analysing a certified reference material Zn/Al/Cu 43XZ3F.  相似文献   

7.
A novel nanomaterial has been developed for speciation of Cr(III) and Cr(VI) in water and soil samples. In this study, a new type of alumina-coated magnetite nanoparticles (Fe3O4/Al2O3 NPs) modified by the surfactant Triton X-114 has been successfully synthesized and used in magnetic mixed hemimicelles solid-phase extraction procedure. The procedure was based on the reaction of chromium(III) with 1-(2-pyridilazo)-2-naphtol as a ligand, yielding a complex, which was entrapped “in situ” in the surfactant hemimicelles. The concentration of chromium(III) was determined using flame atomic absorption spectrometry. After reduction of Cr(VI) to Cr(III) by ascorbic acid, the system was applied to the total chromium. Cr(VI) was then calculated as the difference between the total Cr and the Cr(III) content. This method can also be used for complicated matrices such as soil samples without any special pretreatment. Under the optimum conditions of parameters, the recoveries of Cr(III) by analyzing the spiked water and soil samples were between 98.6 and 100.8 % and between 96.5 and 100.7 %, respectively. Detection limits of Cr(III) were between 1.4 and 3.6 ng?mL?1 for water samples and 5.6 ng?mg?1 for soil samples.  相似文献   

8.
A new complexing agent, 2-((2-((1H-benzo[d]imidazole-2yl)methoxy)phenoxy)methyl)-1H-benzo[d]imidazole (BIMPI), was used in cloud point extraction and applied for selective pre-concentration of trace amounts of cadmium in cigarette samples. Cadmium was complexed with BIMPI in a buffer solution (pH?=?10) using Triton X-114 as surfactant and quantitatively extracted into a small volume of the surfactant-rich phase after centrifugation. Under optimized conditions (pH?=?10.0, 0.8?×?10?4?mol?L?1 BIMPI and 0.08 % (w/v) Triton X-114), calibration graph was linear in the range of 34.0–1,670.0 μg?L?1. The proposed method was applied to the determination of Cd in various cigarette (tobacco) samples which gave satisfactory results.  相似文献   

9.
The residual levels of dichlorodiphenyltrichloroethane (DDT) and its metabolites (DDXs, including p,p′-DDT, DDD, and DDE) in water, suspended particulate matter (SPM), and sediments from major rivers, lakes, and reservoirs in Haihe Plain were measured with a gas chromatograph equipped with a 63Ni microelectron capture detector. In the fall of 2004, the contents of the total DDXs in the water and SPM were 0.29?±?0.69 ng L?1 and 423.13?±?577.85 ng g?1 dry wt., respectively. In the spring of 2005, the total DDXs were 0.36?±?0.91 ng L?1 for water and 35.93?±?62.65 ng g?1 dry wt. for SPM. The average concentration of DDXs for sediments was 7.10?±?7.57 ng g?1 dry wt. during the two seasons. The Eastern-Hebei-Province Coastland River System was the most polluted, which was mainly attributable to the extensive use of DDT pesticide and dicofol in that system. Recent DDT inputs still occur in some regions, as indicated by DDT/(DDD + DDE) > 1 at 29–36 % of the sites for water and 55–61 % of the sites for SPM. The potential ecological risks of DDT in the water were assessed using a species sensitivity distribution model. Only shrimp and crabs were found to have potentially affected fraction values of 1.63?×?10?3 to 2.27?×?10?4, with probabilities beyond the hazardous concentration for 5 % of species (HC5) values of 1.90–2.56 %, suggesting only slight risks. DDXs in the sediments of some sites were also of potential risk to benthic organism based on consensus-based sediment quality guidelines.  相似文献   

10.
The major objective of this investigation was to evaluate the potential of scented geraniums, Pelargonium roseum, to uptake and accumulate heavy metals nickel (Ni), cadmium (Cd), or lead (Pb). For this, plants were grown in an artificial soil system and exposed to a range of metal concentrations over a 14-day treatment period. Then, metals from the entire biomass were extracted. The results showed that scented geranium plants accumulated in excess of 20,055 mg of Ni kg?1 dry weight (DW) of root and 10,889 mg of Ni kg?1 DW of shoot, and in excess of 86,566 mg of Pb kg?1 DW for roots and 4,416 mg of Pb kg?1 DW for shoots within 14 days. Also, the uptake and accumulation of cadmium in roots of scented geranium plants increased with the exposure at low (250, 500 mg?L?1) and medium level (750 mg?L?1) followed by a decline at the highest level (1,000 mg?L?1). The highest accumulation in roots (31,267 mg?kg?1 DW) was observed in 750 mg?L?1 cadmium treatment. In the shoots of scented geraniums, the highest amount of metal accumulation (1,957 mg?kg?1 DW) was detected at 750 and 1,000 mg?L?1 of cadmium in the culture solution. Finally, since the high concentrations of Ni or Pb accumulated in shoots of scented geranium has far exceeded 0.1 % DW and for Cd has far exceeded 0.01 % DW, P. roseum is a new hyperaccumulator species for these metals and can be used in phytoremediation industry.  相似文献   

11.
The paper presents the first report on the application of a lead film electrode for the determination of ultratrace concentrations of platinum. The procedure is based on preconcentration of the Pt(IV)-formaldehyde complexes at an in situ plated lead film electrode held at ?0.9 V (vs. Ag/AgCl), followed by a negatively sweeping differential pulse voltammetric scan. The composition of the supporting electrolyte, the influence of accumulation potential and time on the sensitivity of platinum responses are discussed. The detection limit of Pt(IV) with the accumulation time of 60 was equal to 9.2?×?10?12 mol L?1. The application of this method was tested by recovery of Pt(IV) from spiked environmental water samples.  相似文献   

12.
The quality of the water in a uranium-ore-mining area located in Caldas (Minas Gerais State, Brazil) and in a reservoir (Antas reservoir) that receives the neutralized acid solution leaching from the waste heaps generated by uranium mining was investigated. The samples were collected during four periods (October 2008, January, April and July 2009) from six sampling stations. Physical and chemical analyses were performed on the water samples, and the data obtained were compared with those of the Brazilian Environmental Standards and WHO standard. The water samples obtained from waste rock piles showed high uranium concentrations (5.62 mg L?1), high manganese values (75 mg L?1) and low average pH values (3.4). The evaluation of the water quality at the point considered the limit between the Ore Treatment Unit of the Brazilian Nuclear Industries and the environment (Consulta Creek) indicated contamination by fluoride, manganese, uranium and zinc. The Antas reservoir showed seasonal variations in water quality, with mean concentrations for fluoride (0.50 mg L?1), sulfate (16 mg L?1) and hardness (20 mg L?1) which were low in January, evidencing the effect of rainwater flowing into the system. The concentrations for fluoride, sulfate and manganese were close or above to the limits established by current legislation at the point where the treated mining effluent was discharged and downstream from this point. This study demonstrated that the effluent discharged by the UTM affected the quality of the water in the Antas reservoir, and thus the treatments currently used for effluent need to be reviewed.  相似文献   

13.
The effective determination of heavy metals from environmental media is among the most important issues for many industrialized countries. The interaction between RS-N, as novel heavy metal probe, and metal ions was studied. RS-N shows selective color change from colorless to pink in the presence of Hg2+ in methanol/water solvent and the UV–Vis study shows peak at 560 nm. Fluorescence data revealed that the fluorescence enhance of RS-N by Hg2+ dramatically was the result of the formation of [Hg2+]RS-N complex. The effective association constants (K a ) were 3.97?×?105 and 0.204?×?105 M?1 for Hg2+ and Cu2+ to RS-N, respectively. The thermodynamic parameters, enthalpy change (ΔH 0) and entropy change (ΔS 0), were calculated to be ?6.431?±?0.226 kJ/mol and ?0.129?±?0.008 J/K/mol, respectively, according to van’t Hoff equation on the basis of Gibbs free energy (ΔG 0) ranged from ?33.8326 to ?28.5389 kJ/mol.  相似文献   

14.
Amberlite XAD-4 resin functionalized with β-nitroso-α-naphthol was applied to an online system for the preconcentration and determination of uranium. U (VI) ions were retained on the minicolumn at an appropriate pH and then desorbed with acid solution. The amount of uranium in the eluate was measured spectrophotometrically at 650 nm using Arsenazo III as a colorimetric reagent. The limit of detection and the preconcentration factor were 1.8 μg L???1 and 10, respectively. The chemical and flow variables affecting the preconcentration were studied. The influence of several ions on the system was also investigated. The method was successfully applied for the evaluation of uranium in water and in effluent samples.  相似文献   

15.
Monitoring of heavy metals was conducted in the Yamuna River considering bioaccumulation factor, exposure concentration, and human health implications which showed contamination levels of copper (Cu), lead (Pb), nickel (Ni), and chromium (Cr) and their dispersion patterns along the river. Largest concentration of Pb in river water was 392 μg L?1; Cu was 392 μg L?1 at the extreme downstream, Allahabad and Ni was 146 μg L?1 at midstream, Agra. Largest concentration of Cu was 617 μg kg?1, Ni 1,621 μg kg?1 at midstream while Pb was 1,214 μg kg?1 at Allahabad in surface sediment. The bioconcentration of Cu, Pb, Ni, and Cr was observed where the largest accumulation of Pb was 2.29 μg kg?1 in Oreochromis niloticus and 1.55 μg kg?1 in Cyprinus carpio invaded at Allahabad while largest concentration of Ni was 174 μg kg?1 in O. niloticus and 124 μg kg?1 in C. carpio in the midstream of the river. The calculated values of hazard index (HI) for Pb was found more than one which indicated human health concern. Carcinogenic risk value for Ni was again high i.e., 17.02?×?10?4 which was larger than all other metals studied. The results of this study indicated bioconcentration in fish due to their exposures to heavy metals from different routes which had human health risk implications. Thus, regular environmental monitoring of heavy metal contamination in fish is advocated for assessing food safety since health risk may be associated with the consumption of fish contaminated through exposure to a degraded environment.  相似文献   

16.
Considering of the basic properties and also the two nitrogen atoms in the structure, hydrazine hydrate was employed to be an amine additive candidate, to build a Ru(bpy) 3 2+ /hydrazine electrochemiluminescence (ECL) system, and ECL of Ru(bpy) 3 2+ has been employed for the determination of hydrazine hydrate in the paper. The result demonstrated that the logarithmic ECL increasing (ΔECL?=?ECLafter addition of hydrazine???ECLbefore addition of hydrazine) versus the logarithmic concentration of hydrazine hydrate is linear over a concentration range of 1.0?×?10?9 to 1.0?×?10?5?mol/L, on both glassy carbon and Pt electrodes in a pH 9 phosphate buffer. The hydrazine hydrate detection limit was down to 1.0?×?10?9?mol/L, comparatively lower than other detection methods. To check its applicability, the proposed method was applied to the determination of hydrazine hydrate added into a tap water sample with good reproducibility and stability. All these provide a possibility to develop a novel ECL detection method for hydrazine in water.  相似文献   

17.
Arsenic is a widespread contaminant in the environment. The intake of water containing high concentrations of arsenic could have serious impact on human health, such as skin and lung cancer. In the European Union, thus, also in Italy, the arsenic limit in drinking water is 10 μg L?1. Several water remediation treatment technologies are available for arsenic removal. For some processes, the removal efficiencies can be improved after an oxidation step. Most full-scale applications are based on conventional oxidation processes for chemical micropollutant removal. However, if water contains arsenic and refractory organic contaminants, the advanced oxidation processes could be considered. The aim of this work was to investigate the effectiveness of ultraviolet (UV) radiation alone and in combination with hydrogen peroxide for the oxidation of arsenic and terbuthylazine (TBA). The experimental tests were performed in groundwater at the laboratory scale (0.1 mg L?1 As(III) and 10 μg L?1 TBA). Hydrogen peroxide alone (15 mg L?1) was ineffective on both arsenic and TBA oxidation; the 253.7-nm radiation alone did not oxidize arsenic(III), but photolyzed efficiently TBA (52 % removal yield at a UV dose of 1,200 mJ cm?2). The UV/H2O2 advanced oxidation (UV dose 600–2,000 mJ cm?2, 5–15 mg L?1 H2O2) was the most effective process for the oxidation of both arsenic and TBA, with observed oxidation efficiencies of 85 and 94 %, respectively, with 5 mg L?1 H2O2 and a UV dose of 2,000 mJ cm?2.  相似文献   

18.
The present research reports on the application of modified multiwalled carbon nanotubes as a new, easily prepared, and stable solid sorbent for the column preconcentration of ultra-trace amounts of cadmium in aqueous solution. Multiwalled carbon nanotubes were oxidized with concentrated HNO3 and modified with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and then were used as a solid phase for the column preconcentration of Cd(II). Elution was carried out with 0.5 mol?L?1 HNO3. The amount of eluted Cd(II) was measured using electrothermal atomic absorption spectrometry. Various parameters such as pH, sample and eluent flow rate, eluent concentration, breakthrough volume, and interference of a great number of anions and cations on the retention of analyte on sorbent were studied. Under the optimized conditions, the calibration graph was linear in the range of 0.67 ng?L?1 to 5.0 μg?L?1 and the detection limit (3Sb, n?=?7) was 0.14 ng?L?1 in initial solution. A preconcentration factor of 300 and relative standard deviations of ±3.6 % for seven successive determinations of 3 ng of Cd(II) were achieved. The column preconcentration was successfully applied to the analysis of river water, waste water, and Persian Gulf water sample.  相似文献   

19.
We assessed the effects of seasonal dynamics on the physico-chemical qualities and heavy metals concentrations of the Umgeni and Umdloti Rivers in Durban, South Africa. Water samples were taken from nine different sampling points and analysed for the following parameters; temperature, pH, turbidity, electrical conductivity (EC), biological oxygen demand (BOD5), chemical oxygen demand (COD), phosphate (PO4 2?), nitrate (NO3 2?), ammonium (NH4 +), sulphate (SO4 2?), lead (Pb2+), mercury (Hg2+), cadmium (Cd2+), aluminium (Al3+), and copper (Cu2+) using standard methods. The data showed variations it terms of the seasonal fluctuations and sampling regime as follows: temperature 12–26.5 °C; pH 5.96–8.45; turbidity 0.53–18.8 NTU; EC 15.8–5180 mS m?1; BOD5 0.60–7.32 mg L?1; COD 10.5–72.9 mg L?1; PO4 2??<?500–2,460 μg L?1; NO3 2? <0.05–4.21 mg L?1; NH4 +?<?0.5–1.22 mg L?1; SO4 2? 3.90–2,762 mg L?1; Pb2+ 0.023–0.135 mg L?1; Hg2+ 0.0122–0.1231 mg L?1 Cd2+ 0.068–0.416 mg L?1; Al3+ 0.037–1.875 mg L?1, and Cu2+0.006–0.144 mg L?1. The concentrations of most of the investigated parameters exceeded the recommended limit of the South African Guidelines and World Health Organization tolerance limits for freshwater quality. We conclude that these water bodies are potentially hazardous to public health and this highlights the need for implementation of improved management strategies of these river catchments for continued sustainability.  相似文献   

20.
Citrus limon peel (kitchen waste) and Leucaena leucocephala seeds (agricultural waste) were used as a modifier for fabrication of modified carbon paste electrode for determination of mercury in aqueous sample using differential pulse anodic stripping voltammetry. Mercury was adsorbed on electrode surface at open circuit and anodic stripping voltammetric scan was run from ?0.5 to 0.5 V. Various electrochemical parameters including amount of modifier, supporting electrolyte, accumulating solvent, pH of the accumulating solvent, and accumulation time were investigated. The effect of presence of other metal ions and surfactants was also studied. In comparison C. limon peel proved to be a better modifier than L. leucocephala seed biomass. This was justified by electrode characterization using cyclic voltammetry that indicated decrease in resistance of electrode when C. limon peel was used as modifier and increase when modifier was L. leucocephala seeds. Maximum current response was obtained using 5 % C. limon peel biomass, hydrochloric acid as supporting electrolyte, acetate buffer of pH 6 as an accumulating solvent, 10-min accumulation time, and scan rate of 50 mV/s. Linear calibration curves were obtained in the concentration range 100 to 1,000 μg L?1 of mercury for accumulation time of 10 min with limit of detection of 57.75 μg L?1 and limit of quantification of 192.48 μg L?1. This technique does not use mercury as electrode material and, therefore, has a positive environmental benefit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号