首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 704 毫秒
1.
Abstract

Efforts to develop multipollutant control strategies have demonstrated that adding certain oxidants to different classes of Ca-based sorbents leads to a significant improvement in elemental Hg vapor (Hg0), SO2, and NOx removal from simulated flue gases. In the study presented here, two classes of Ca-based sorbents (hydrated limes and silicate compounds) were investigated. A number of oxidizing additives at different concentrations were used in the Ca-based sorbent production process. The Hg0, SO2, and NOx capture capacities of these oxidant-enriched sorbents were evaluated and compared to those of a commercially available activated carbon in bench-scale, fixed-bed, and fluid-bed systems. Calcium-based sorbents prepared with two oxidants, designated C and M, exhibited Hg0 sorp-tion capacities (~100 μg/g) comparable to that of the activated carbon; they showed far superior SO2 and NOx sorption capacities. Preliminary cost estimates for the process utilizing these novel sorbents indicate potential for substantial lowering of control costs, as compared with other processes currently used or considered for control of Hg0, SO2, and NOx emissions from coal-fired boilers. The implications of these findings toward development of multipollutant control technologies and planned pilot and field evaluations of more promising multipollutant sorbents are summarily discussed.  相似文献   

2.
The U.S. EPA’s Air and Energy Engineering Research Laboratory is responsible for assessing control technology performance and costs under the National Acid Precipitation Assessment Program. A major part of this assessment involves developing site-specific estimates of the performance and costs of retrofitting SO2 and NOx control technologies for the top 200 SO2- emitting (1980) coal-fired power plants in the 31-state eastern region. This effort includes detailed evaluation of a small number of plants (30 or less) representing a cross-section of the top 200 population. In cooperation with the states of Ohio and Kentucky (in conjunction with the U.S. EPA’s State Acid Rain Grant Program), efforts were undertaken to visit and conduct detailed evaluation of 12 coal-fired plants—five in Ohio, seven in Kentucky and the Tennessee Valley Authority System. A variety of commercial and advanced SO2 and NOx control technologies—including precombustion, combustion (in-furnace), and postcombustion (flue gas cleanup) technologies—were applied to each plant through conceptual designs. Retrofit factors (applied to the capital cost of a new pollution control system), cost “adders” (e.g., movement of existing equipment), and costs were developed for applying the control technologies to the boilers of each plant. Results of these and subsequent efforts will be valuable in evaluations of acid deposition control strategies by federal and state agencies and by electric utilities.  相似文献   

3.
ABSTRACT

At conditions typical of a bag filter exposed to a coal-fired flue gas that has been adiabatically cooled with water, calcium hydroxide and calcium silicate solids were exposed to a dilute, humidified gas stream of nitrogen dioxide (NO2) and sulfur dioxide (SO2) in a packed-bed reactor. A prior study found that NO2 reacted readily with surface water of alkaline and non-alkaline solids to produce nitrate, nitrite, and nitric oxide (NO). With SO2 present in the gas stream, NO2 also reacted with S(IV), a product of SO2 removal, on the exterior of an alkaline solid. The oxidation of S(IV) to S(VI) by oxygen reduced the availability of S(IV) and lowered removal of NO2. Subsequent acidification of the sorbent by the removal of NO2 and SO2 facilitated the production of NO. However, the conversion of nitrous acid to sulfur-nitrogen compounds reduced NO production and enhanced SO2 removal. A reactor model based on empirical and semi-empirical rate expressions predicted rates of SO2 removal, NO2 removal, and NO production by calcium silicate solids. Rate expressions from the reactor model were inserted into a second program, which predicted the removal of SO2 and NOx by a continuous process, such as the collection of alkaline solids in a baghouse. The continuous process model, depending upon inlet conditions, predicted 30-40% removal for NO and 50-90% removal for SO2. These x 2 results are relevant to dry scrubbing technology for combined SO2 and NOx removal that first oxidizes NO to NO2 by the addition of methanol into the flue duct.  相似文献   

4.
The utility and industrial sectors continue to come under pressure from both national and local regulatory groups to reduce sulfur dioxide emissions. With a trend in the utility industry for life extension, retrofit technologies are likely to play an important role in any SO2 emission reduction strategy. Potential retrofit technologies include, singly and in combination: coal switching or cleaning, wet or dry FGD, conversion to fluidized bed, and dry sorbent injection. The diversity within the utility industry in terms of unit size, unit age, fuel use, financial base, and geographic location dictates the need for a variety of technologies to address SO2 emission control. Dry injection processes involving the injection of dry powders into either the furnace or post-furnace region offer the potential for low capital cost retrofitable technologies. However, compared to wet FGD processes, the dry calcium based processes will likely have lower SO2 removal efficiencies and may pose more plant-wide integration issues that need to be addressed from both an applications and R&D perspective.

This paper provides a critical assessment of dry injection technologies, in two parts. Part 1 focuses on sorbent processes and science. An assessment of the different dry sorbent processes and the effect of process parameters is provided. Emphasis is placed on process limitations and potential avenues to enhance SO2 removal. Part 2 will deal with applications of the technology, addressing cost, scale-up, and integration issues.

Much of the data included in this paper was presented at the 1986 Joint Symposium on Dry SO2 and Simultaneous SO2/NOx Control Technologies, sponsored by the Electric Power Research Institute and the Environmental Protection Agency and held in June 1986. This paper provides both an overview and an evaluation of the technology, based largely on our analysis of the data and interpretations discussed at this symposium.  相似文献   

5.
The injection of dry alkaline compounds into the furnace or post-furnace regions of utility boilers to reduce SO2 is currently under development as a lower cost option to conventional flue gas desulfurization technology. Part I of this paper focused on the science and process development of the various dry sorbent technologies. Part II will address applications of these technologies, including SO2 removals in full-scale boilers, methodologies for designing sorbent injection systems, power plant impacts, process integration issues, and cost.

Because the dry technologies use the furnace and/or ducts as the chemical contactor, potential impacts on power plant operation and reliability are as critical in assessing the commercial applicability of each technology as SO2 removal and sorbent utilization. Consequently, the technical and economic feasibility of the various dry processes is highly site specific.  相似文献   

6.
Under the 11th Five Year Plan (FYP, 2006–2010) for national environmental protection by the Chinese government, the overarching goal for sulfur dioxide (SO2) controls is to achieve a total national emissions level of SO2 in 2010 10% lower than the level in 2005. A similar nitrogen oxides (NOx) emissions control plan is currently under development and could be enforced during the 12th FYP (2011–2015). In this study, the U.S. Environmental Protection Agency (U.S.EPA)’s Community Multi-Scale Air Quality (Models-3/CMAQ) modeling system was applied to assess the air quality improvement that would result from the targeted SO2 and NOx emission controls in China. Four emission scenarios — the base year 2005, the 2010 Business-As-Usual (BAU) scenario, the 2010 SO2 control scenario, and the 2010 NOx control scenario—were constructed and simulated to assess the air quality change from the national control plan. The Fifth-Generation NCAR/Penn State Mesoscale Model (MM5) was applied to generate the meteorological fields for the CMAQ simulations. In this Part I paper, the model performance for the simulated meteorology was evaluated against observations for the base case in terms of temperature, wind speed, wind direction, and precipitation. It is shown that MM5 model gives an overall good performance for these meteorological variables. The generated meteorological fields are acceptable for using in the CMAQ modeling.  相似文献   

7.
On June 5 and 6 of 1980, two parallel plume oxidation studies were carried out in the vicinity of the Tennessee Valley Authority's Colbert Steam Plant. One study was performed in a smog chamber into which stack gases were injected and mixed with ambient air. The other study included direct airborne sampling of the power plant plume. Atmospheric oxidation rates for the conversion of SO2 to SO4 2- and the removal rates of NO x (which is presumably the rate of NO3 - formation) were estimated for both studies. The SO2 to SO4 2- rate coefficients were found to be 0.022 ± 0.009 h-1 for both chamber experiments and the first airborne sampling day. For the second day, a rate constant of 0.041 ± 0.052 h-1 was estimated from the aircraft data. The large deviation in this value is explained by the fact that the plume from the power plant combined and reacted with the urban plume from the city of Florence, AL. The formation of a very large "O3 bulge" on this day is also attributed to the mixed plumes. The first order rate coefficients for NO x removal were estimated to be 0.27 ± 0.14 h-1 for both chamber experiments and the first airborne sampling day. A NO x removal rate could not be determined for the second airborne sampling day.  相似文献   

8.
Two indicator pollutants, carbon monoxide (CO) for mobile source influence and sulfur dioxide (SO2) for stationary source influence, were used to estimate source-type contributions to ambient NO2 levels in a base year and to predict NO2 concentrations in a future year. For a specific source-receptor pair, the so-called influence coefficient of each of three source categories (mobile sources, power plants, and other stationary sources) was determined empirically from concurrent measurements of CO and SO2 concentrations at the receptor site and CO and SO2 emissions from each source category in the source area. Those coefficients, which are considered time invariant, were used in conjunction with the base year and future year NO x emission values to estimate source-type contribution to ambient NO2 levels at seven study sites selected from the Greater Los Angeles area for both the base year period, 1974 through 1976, and the future goal year of 1987 in which the air quality standards for NO2 are to be attained. The estimated NO2 air quality at the seven sites is found to meet the national annual standard of 5 pphm and over 99.9% of total hours, the California 1-hr NO2 standard of 25 pphm in 1987. The estimated power plant contributions to ambient NO2 levels are found to be considerably smaller than those to total NO x emissions in the area. Providing that reasonably complete air quality and emissions data are available, the present analysis method may prove to be a useful tool in evaluating source contributions to both short-term peak and long-term average NO2 concentrations for use in control strategy development.  相似文献   

9.
The IAPCS model, developed by U.S. EPA’s Air and Energy Engineering Research Laboratory and made available to the public through the National Technical Information Service, can be used by utility companies, architectural and engineering companies, and regulatory agencies at all levels of government to evaluate commercially available technologies for control of SO2, NOx, and particulate matter emissions from coal-fired utility boilers with respect to performance and cost. The model is considered to be a useful tool to compare alternative control strategies to be used by utilities to comply with the requirements of the CAA, and to evaluate the sensitivity of control costs with respect to many of the significant variables affecting costs.

To illustrate the use of the model for site-specific studies, the authors used the model to estimate control costs for SO2 and NOx control at Detroit Edison’s Monroe plant and two hypothetical plants under consideration and at three plants operated by New York State Electric and Gas Corporation. The economic and technical assumptions used to drive the model were those proposed by the utilities if cited, and if not cited, the model default values were used. The economic format and methodologies for costs cited in the Electric Power Research Institute’s Technical Assessment Guide are used in the IAPCS model. Depending on the specific conditions and assumptions for the cases evaluated, SO2 control costs ranged from $417 to $3,159 per ton of SO2 removed, and NOx control costs ranged from $461 to $3,537 per ton of NOx removed or reduced.  相似文献   

10.
Emissions of pollutants such as SO2 and NOx from external combustion sources can vary widely depending on fuel sulfur content, load, and transient conditions such as startup, shutdown, and maintenance/malfunction. While monitoring will automatically reflect variability from both emissions and meteorological influences, dispersion modeling has been typically conducted with a single constant peak emission rate. To respond to the need to account for emissions variability in addressing probabilistic 1-hr ambient air quality standards for SO2 and NO2, we have developed a statistical technique, the Emissions Variability Processor (EMVAP), which can account for emissions variability in dispersion modeling through Monte Carlo sampling from a specified frequency distribution of emission rates. Based upon initial AERMOD modeling of from 1 to 5 years of actual meteorological conditions, EMVAP is used as a postprocessor to AERMOD to simulate hundreds or even thousands of years of concentration predictions. This procedure uses emissions varied hourly with a Monte Carlo sampling process that is based upon the user-specified emissions distribution, from which a probabilistic estimate can be obtained of the controlling concentration. EMVAP can also accommodate an advanced Tier 2 NO2 modeling technique that uses a varying ambient ratio method approach to determine the fraction of total oxides of nitrogen that are in the form of nitrogen dioxide. For the case of the 1-hr National Ambient Air Quality Standards (NAAQS, established for SO2 and NO2), a “critical value” can be defined as the highest hourly emission rate that would be simulated to satisfy the standard using air dispersion models assuming constant emissions throughout the simulation. The critical value can be used as the starting point for a procedure like EMVAP that evaluates the impact of emissions variability and uses this information to determine an appropriate value to use for a longer term (e.g., 30-day) average emission rate that would still provide protection for the NAAQS under consideration. This paper reports on the design of EMVAP and its evaluation on several field databases that demonstrate that EMVAP produces a suitably modest overestimation of design concentrations. We also provide an example of an EMVAP application that involves a case in which a new emission limitation needs to be considered for a hypothetical emission unit that has infrequent higher-than-normal SO2 emissions.
ImplicationsEmissions of pollutants from combustion sources can vary widely depending on fuel sulfur content, load, and transient conditions such as startup and shutdown. While monitoring will automatically reflect this variability on measured concentrations, dispersion modeling is typically conducted with a single peak emission rate assumed to occur continuously. To realistically account for emissions variability in addressing probabilistic 1-hr ambient air quality standards for SO2 and NO2, the authors have developed a statistical technique, the Emissions Variability Processor (EMVAP), which can account for emissions variability in dispersion modeling through Monte Carlo sampling from a specified frequency distribution of emission rates.  相似文献   

11.
The body of Information presented in this paper is directed to those Individuals concerned with the removal of NOx in combustion flue gases. A catalytic process for the selective reduction of nitrogen oxides by ammonia has been investigated. Efforts were made toward the development of catalysts resistant to SOx poisoning. Nitrogen oxides were reduced over various metal oxide catalysts in the presence or absence of SOx(SO2 and SO3). Catalysts consisting of oxides of base metals (for example, Fe2O3) were easily poisoned by SO3, forming sulfates of the base metals. A series of catalysts which are not susceptible to the SOx poisoning has been developed. The catalysts possess a high activity and selectivity over a wide range of temperatures, 250—450°C. The catalysts were tested in a pilot plant which treated a flue gas containing 110-150 ppm NOx, 660-750 ppm SO2, and 40-90 ppm SO3. The pilot plant was operated at 350°C and at a space velocity of 10,000 h-1. The removal of nitrogen oxides was more than 90% for several months.

A mechanism of the NO-NH3 reaction has also been investigated. It is found that NO reacts with NH3 at a 1:1 mole ratio in the presence of oxygen and the reaction is completely inhibited by the absence of oxygen. The experimental data show that the NO-NH3 reaction in the presence of oxygen is represented byNO + NH3 + 1/4 O2 = N2 + 3/2 H2O.  相似文献   

12.
ABSTRACT

This article presents the results of an industrial-scale study (on 400 MWe lignite fired unit) of simultaneous NOx, SO2, and HgT removal in FGD absorber with oxidant injection (NaClO2) into flue gas. It was confirmed that the injection of sodium chlorite upstream the FGD (Flue Gas Desulfurization) absorber oxidize NO to NO2, Hg0 to Hg2+, and enhancing NOx and HgT removal efficiency from exhaust gas in FGD absorber. Mercury removal efficiency grows with the rise of degree of oxidation NO to NO2 and was limited by the phenomenon of re-emission. For NOx removal the most critical parameters is slurry pH and temperature. There was no negative effect on sulfur dioxide removal efficiency caused by oxidant injection in tested FGD absorber. Based on the data provided, NOx and HgT emissions can be reduced by adjusting the FGD absorber operating parameters combined with oxidant injection.  相似文献   

13.
Sub-regional and sector level distribution of SO2 and NOx emissions inventories for India have been estimated for all the 466 Indian districts using base data for years 1990 and 1995. Although, national level emissions provide general guidelines for assessing mitigation alternatives, but significant regional and sectoral variability exist in Indian emissions. Districts reasonably capture this variability to a fine grid as 80% of these districts are smaller than 1°×1° resolution with 60% being smaller than even 1/2°×1/2°. Moreover, districts in India have well-established administrative and institutional mechanisms that would be useful for implementing and monitoring measures. District level emission estimates thus offer a finer regional scale inventory covering the combined interests of the scientific community and policy makers. The inventory assessment methodology adopted is similar to that prescribed by the Intergovernmental Panel on Climate Change (IPCC) for greenhouse gas (GHG) emissions. The sectoral decomposition at district level includes emissions from fossil fuel combustion, non-energy emissions from industrial activities and agriculture. Total SO2 and NOx emissions from India were 3542 and 2636 Gg, respectively (1990) and 4638 and 3462 Gg (1995) growing at annual rate of around 5.5%. The sectoral composition of SO2 emissions indicates a predominance of electric power generation sector (46%). Power and transport sector emissions equally dominate NOx emissions contributing nearly 30% each. However, majority of power plants are situated in predominantly rural districts while the latter are concentrated in large urban centers. Mitigation efforts for transport sector NOx emissions would therefore be higher. The district level analysis indicates diverse spatial distribution with the top 5% emitting districts contributing 46.5 and 33.3% of total national SO2 and NOx emissions, respectively. This skewed emission pattern, with a few districts, sectors and point sources emitting significant SO2 and NOx, offers mitigation flexibility to policy makers for cost-effective mitigation.  相似文献   

14.
Sodium hypochlorite (NaClO) has been widely used as a chemical additive for enhancing nitrogen oxide (NOx; NO + NO2), sulfur dioxide (SO2), and mercury (Hg0) removals in a wet scrubber. However, they are each uniquely dependent on NaClO(aq) pH, hence making the simultaneous control difficult. In order to overcome this weakness, we sprayed low liquid-to-gas (L/G) ratio (0.1 L/Nm3) of NaClO(aq) to vaporize quickly at 165 °C. Results have shown that the maximized NOx, SO2, and Hg0 removals can be achieved at the pH range between 4.0 and 6.0. When NOx and Hg0 coexist with SO2, in addition, their removals are significantly enhanced by reactions with solid and gaseous by-products such as NaClO(s), NaClO2(s), OClO, ClO, and Cl species, originated from the reaction between SO2 and NaClO(aq). We have also demonstrated the feasibility of this approach in the real flue gases of a combustion plant and observed 50%, 80%, and 60% of NOx, SO2, and Hg0 removals, respectively. These findings led us to conclude that the spray of NaClO(aq) at a relatively high temperature at which the sprayed solution can vaporize quickly makes the simultaneous control of NOx, SO2, and Hg0 possible.

Implications: The simple spray of NaClO(aq) at temperatures above 165 °C can cause the simultaneous removal of gaseous NOx, SO2, and Hg0 by its quick vaporization. Their maximized removals are achieved at the pH range between 4.0 and 6.0. NOx and Hg0 removals are also enhanced by gaseous and solid intermediate products generated from the reaction of SO2 with NaClO(aq). The feasibility of this approach has been demonstrated in the real flue gases of a combustion plant.  相似文献   


15.
An analysis of air quality data from 1970-1975 in the Los Angeles (LA) Basin has been made with emphasis on factors relevant to high hourly NO2 concentrations, (NO2). Detailed analysis of CO and SO2 air quality and the (NO x )/(CO) and (CO)/(SO2) ratios reveals that high (NO2) result mainly from vehicular sources; contributions from stationary sources to these high (NO2) of greater than 10% occur rarely. Meteorological conditions (very low early-morning inversion base height and low wind speed) favoring the formation of high (NO2) restrict the impact of elevated point NO x sources on the ground level (NO2) during the early to mid-morning hours. The overnight leftover NO x during high NO2 days is shown to originate largely from local sources near the monitoring sites. A regression analysis using NO2, NO x and HC data from downtown LA shows that a 50% reduction in (NO x ) reduces high (NO2) by 40-45%; a 50% reduction in (HC) reduces high (NO2) by 5-10%. The present analysis supports assumptions used in an earlier generalized rollback model that related NO x emissions to high 1-h average (NO2) observed at downtown LA.  相似文献   

16.
A highly resolved temporal and spatial Pearl River Delta (PRD) regional emission inventory for the year 2006 was developed with the use of best available domestic emission factors and activity data. The inventory covers major emission sources in the region and a bottom–up approach was adopted to compile the inventory for those sources where possible. The results show that the estimates for SO2, NOx, CO, PM10, PM2.5 and VOC emissions in the PRD region for the year 2006 are 711.4 kt, 891.9 kt, 3840.6 kt, 418.4 kt, 204.6 kt, and 1180.1 kt, respectively. About 91.4% of SO2 emissions were from power plant and industrial sources, and 87.2% of NOx emissions were from power plant and mobile sources. The industrial, mobile and power plant sources are major contributors to PM10 and PM2.5 emissions, accounting for 97.7% of the total PM10 and 97.2% of PM2.5 emissions, respectively. Mobile, biogenic and VOC product-related sources are responsible for 90.5% of the total VOC emissions. The emissions are spatially allocated onto grid cells with a resolution of 3 km × 3 km, showing that anthropogenic air pollutant emissions are mainly distributed over PRD central-southern city cluster areas. The preliminary temporal profiles were established for the power plant, industrial and on-road mobile sources. There is relatively low uncertainty in SO2 emission estimates with a range of −16% to +21% from power plant sources, medium to high uncertainty for the NOx emissions, and high uncertainties in the VOC, PM2.5, PM10 and CO emissions.  相似文献   

17.
ABSTRACT

This paper presents a technique for the complete, simultaneous decomposition of CO2, SO2, and NOx, as well as the simultaneous removal of fly ash by ultra-high voltage pulse activation. Ultra-high voltage narrow pulse is used to make the gases in the reactor become active molecules, which are then dissociated into nonpoisonous gas molecules and solid particles under the control of a directional reaction model. By using a sufficient charge and a strong electric field, the fly ash can be removed. It becomes the carrier of C and S, and its efficiency is 99.5%. Owing to the action of catalyst B (using Ni as the mother's body), the activation energy of CO2, SO2, and NOx gases is reduced in great magnitude, and their removal efficiency can reach 75~90% at normal pressure and 180 °C.  相似文献   

18.
Abstract

Understanding ozone response to its precursor emissions is crucial for effective air quality management practices. This nonlinear response is usually simulated using chemical transport models, and the modeling results are affected by uncertainties in emissions inputs. In this study, a high ozone episode in the southeastern United States is simulated using the Community Multiscale Air Quality (CMAQ) model. Uncertainties in ozone formation and response to emissions controls due to uncertainties in emission rates are quantified using the Monte Carlo method. Instead of propagating emissions uncertainties through the original CMAQ, a reduced form of CMAQ is formulated using directly calculated first- and second-order sensitivities that capture the nonlinear ozone concentration-emission responses. This modification greatly reduces the associated computational cost. Quantified uncertainties in modeled ozone concentrations and responses to various emissions controls are much less than the uncertainties in emissions inputs. Average uncertainties in modeled ozone concentrations for the Atlanta area are less than 10% (as measured by the inferred coefficient of variance [ICOV]) even when emissions uncertainties are assumed to vary between a factor of 1.5 and 2. Uncertainties in the ozone responses generally decrease with increased emission controls. Average uncertainties (ICOV) in emission-normalized ozone responses range from 4 to 22%, with the smaller being associated with controlling of the relatively certain point nitrogen oxide (NOx) emissions and the larger resulting from controlling of the less certain mobile NOx emissions. These small uncertainties provide confidence in the model applications, such as in performance evaluation, attainment demonstration, and control strategy development.  相似文献   

19.
低温选择性催化还原(SCR)脱硝是国内外脱硝技术研发的热点,但目前主要集中在实验室小试范围,无法完全反映催化剂在实际烟气中的运行状况。在30 t/h循环流化床燃煤锅炉脱硫除尘装置后建设了2 000~5 000 m3/h的SCR脱硝中试装置,经系统研究发现,中试使用的蜂窝式催化剂对SO2和NO具有很强的吸附能力,且反应温度、喷氨速率和气体空速均会影响催化脱硝效率。为期5 d的连续运行实验结果表明,催化剂的脱硝效率一直稳定在30%~50%,并未发现明显的失活,这证明设计除雾除尘器、较大的混合器、混合器与反应器间较长的管路均有利于缓解催化剂因SO2、H2O和飞灰中的碱性金属导致的失活。  相似文献   

20.
The 1991 SO2 Control Symposium was held December 3-6, 1991, in Washington, D.C. The symposium, jointly sponsored by the Electric Power Research Institute (EPRI), the U.S. Environmental Protection Agency (EPA), and the U.S. Department of Energy (DOE), focused attention on recent improvements in conventional sulfur dioxide (SO2) control technologies, emerging processes, and strategies for complying with the Clean Air Act Amendments of 1990. Its purpose was to provide a forum for the exchange of technical and regulatory information on SO2 control technology. Over 800 representatives of 20 countries from government, academia, flue gas desulfurization (FGD) process suppliers, equipment manufacturers, engineering firms, and utilities attended. In all, 50 U.S. utilities and 10 utilities in other countries were represented. In 11 technical sessions, a diverse group of speakers presented 111 technical papers on development, operation, and commercialization of wet and dry FGD, Clean Coal Technologies, and combined sulfur dioxide/nitrogen oxides (SO2/NOx processes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号