首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
利用异相膜电渗析装置去除氨法烟气脱硫浆液中的F~-。考察了脱硫浆液p H、F~-初始质量浓度、Cl~-初始质量浓度、膜堆两端电压、浓缩室和淡化室循环流量等操作参数对F~-去除效果的影响。实验结果表明:在酸性条件下,F~-去除率更高;脱硫浆液中F~-初始质量浓度越高,F~-去除率越高;Cl~-初始质量浓度较低时会增加F~-去除率,过高时又会降低F~-去除率。优化的操作条件为:膜堆两端电压25 V,浓缩室和淡化室循环流量300 L/h。一级电渗析进行100 min后,Cl~-去除率接近100%,F~-去除率只有47.3%。二级电渗析进行100 min时,F~-去除率达92.2%。一、二级电渗析F~-累积去除率达96.1%。  相似文献   

2.
活性碳纤维吸附处理对硝基苯酚生产废水   总被引:1,自引:1,他引:0  
采用活性碳纤维(ACF)吸附处理对硝基苯酚(PNP)生产废水,考察了动态吸附和脱附过程.实验结果表明,在298 K、pH 4时,最佳进水流量为0.25 L/h,ACF的有效吸附量为439.3 mg/g,PNP去除率大于99.95%,TOC去除率大于99.5%,脱附率大于99.5%,ACF的吸附--脱附性能稳定.ACF吸附和电解相结合的工艺能有效去除废水中的有害物质,回收利用PNP和氯化钠,实现了PNP的清洁生产.  相似文献   

3.
以四氢呋喃和N,N-二甲基甲酰胺为溶剂,配制三元乙丙橡胶(EPDM)纺丝液,通过静电纺丝技术制备了EPDM超细纤维,进而以聚偏氟乙烯(PVDF)微滤膜为基膜制备了EPDM超细纤维复合膜。采用红外光谱(FTIR)和扫描电子显微镜(SEM)对EPDM超细纤维的结构和形态进行了表征。考察了复合膜对苯乙烯废水的截留效果和复合膜通量的变化情况。实验结果表明:EPDM超细纤维具有类似无纺布形式的多孔纤维网状结构,其直径在0.2~2.0μm之间;复合膜在操作压力为0.1MPa的条件下,处理质量浓度为100μg/mL的模拟苯乙烯废水,膜通量约为5.90mL/(cm2.h),苯乙烯去除率可达89.7%。  相似文献   

4.
水稻秸秆生物炭-过硫酸盐去除水中p-硝基酚   总被引:1,自引:0,他引:1       下载免费PDF全文
以水稻秸秆为原料制备了多种生物炭,运用BET和FTIR等技术对其进行了表征,研究了生物炭-过硫酸盐体系对水中p-硝基酚的去除效果。与热解温度和时间相比,供氧量对生物炭活化过硫酸盐性能的影响更为显著,足氧条件下的活化性能显著降低;500℃缺氧条件下热解1 h制备的生物炭(RS500-1)对过硫酸盐具有良好的活化性能,可以实现p-硝基酚的高效去除,生物炭与过硫酸盐之间存在显著的协同作用。初始溶液pH和反应温度对p-硝基酚的去除效果影响很小;在RS500-1投加量1.0 g/L、过硫酸盐投加量5 mmol/L、反应温度25℃、不调节初始溶液pH的优化条件下,240 min时p-硝基酚的去除率可达70%以上。  相似文献   

5.
平春霞  邢琳 《化工环保》2012,32(4):339-342
采用高效混凝沉降—超滤工艺对循环冷却水排水进行预处理后,考察了NF-A、NF-B和NF-C型纳滤膜的运行情况和处理效果.实验结果表明:NF-A膜对COD、Ca2+和Mg2+的去除率均较低,对Clˉ没有去除效果;NF-C膜对COD、Ca2+、Mg2+和SO42-的去除率均较高,对Clˉ去除率为83.1%,但运行压力较高;NF-B膜运行压力居中,对COD去除率为95.9%,对Ca2+去除率为98.3%,对Mg2+去除率为93.4%,对SO42-去除率为98.2%,对Clˉ去除率为67.4%,处理后出水达到循环回用的要求.  相似文献   

6.
用水解酸化池-膜生物反应器处理活性艳红X-3B废水   总被引:1,自引:0,他引:1  
采用水解酸化池-膜生物反应器处理含活性艳红X-3B的模拟废水,研究了水力停留时间(HRT)对水解酸化池废水处理效果的影响,考察了水解酸化池-膜生物反应器对废水的处理效果及膜生物反应器中污泥沉降性能对膜污染的影响。实验结果表明:水解酸化池HRT为16h时,废水的可生化性最好,挥发性脂肪酸质量浓度与COD比值为0.5;HRT为17h时,废水脱色率达69%,而COD的去除率受HRT影响较小;膜生物反应器主要起去除废水中COD的作用;水解酸化池-膜生物反应器处理后废水的脱色率和COD去除率分别为83%和97%;膜生物反应器中活性污泥沉降性能的变化直接影响膜污染的速率。  相似文献   

7.
对比了酸析法和碱析法对碱法草浆造纸黑液中木质素的去除效果,并分析了聚合氯化铝(PAC)絮凝剂对酸析和碱析后木质素的絮凝效果。实验结果表明:酸析法和碱析法都能有效析出造纸黑液中的木质素,酸析法对色度的去除效果要优于碱析法;当造纸黑液pH为3时,COD去除率达到72.0%,色度去除率为97.7%;当造纸黑液pH为13时,COD去除率达到55.0%,色度去除率为22.3%;PAC对于酸析后木质素有较好的絮凝效果,当废水温度为55℃、PAC加入量为45mL/L时,COD去除率可以达到79.5%,色度去除率为98.5%;PAC絮凝剂对于碱析后的造纸黑液色度的去除效果较差。  相似文献   

8.
采用混凝—Fenton法深度处理维生素B12废水,考察各操作参数对COD和色度去除效果的影响。实验结果表明:当混凝pH 4.5、聚合硫酸铁加入量300 mg/L、氧化pH 4.0、H2O2加入量420 mg/L、FeSO4?7H2O加入量334 mg/L、Fenton反应时间3 h时,混凝—Fenton法对维生素B12废水的深度处理效果较好,总COD和总色度的去除率分别为62.1%和90.0%;与Fenton法相比,混凝—Fenton法COD和色度去除率的提高率分别为17.4%和13.8%,且药剂成本降低了21.6%。  相似文献   

9.
王珺  程学文  张宾  莫馗 《化工环保》2019,39(2):137-141
采用缺氧膨胀床(AEB)反应器处理高浓度硝酸盐废水,研究了反应器的快速启动和挂膜特性,以及在反硝化连续流运行条件下对废水的处理效果。实验结果表明:采用自然挂膜方式,填料层从下至上生物膜厚度逐渐增加;AEB的快速启动8 d可完成,COD去除率由44.9%升至92.3%,NO_3~--N去除率由39.8%升至98.4%;稳定运行阶段(进水COD 4 628~5 548 mg/L、ρ(NO_3~--N) 1 339~1 505 mg/L),COD去除率稳定在95%左右,NO_3~--N去除率稳定在98%~99%,COD和NO_3~--N的容积负荷去除量最高可达27.8 kg/(m~3·d)和7.3 kg/(m~3·d)。  相似文献   

10.
采用天然黄铁矿对水中的Cr(Ⅵ)进行吸附去除,考察了Cr(Ⅵ)去除效果的影响因素,并对吸附机理进行了探讨。实验结果表明:黄铁矿吸附去除水中Cr(Ⅵ)的优化条件为黄铁矿过200目筛(粒径小于0.075 mm)、吸附p H 3.0、黄铁矿投加量20 g/L、初始Cr(Ⅵ)质量浓度6 mg/L、吸附温度25℃,此条件下平衡时的Cr(Ⅵ)去除率达90%以上;酸性条件下,黄铁矿对Cr(Ⅵ)的去除效果均较好,且p H越低达到平衡所需时间越短;黄铁矿粒径越小,其对Cr(Ⅵ)的吸附速率越快,平衡时的去除率也越高;黄铁矿对Cr(Ⅵ)的吸附过程符合Langmuir等温吸附模型和Lagergren准二级动力学方程。  相似文献   

11.
络合萃取法处理高浓度CLT酸废水的研究   总被引:1,自引:0,他引:1  
采用7301正辛醇-H2SO4-NaOH化学萃取-反萃取体系对CLT酸废水进行了络合萃取处理试验。静态杯皿试验表明,通过萃取处理,CLT酸废水的COD去除率达93.5%.反萃取效率100%,废水中的回收物浓缩8~10倍,且萃取剂可再生回用。  相似文献   

12.
废聚苯乙烯硝化氧化制对硝基苯甲酸   总被引:7,自引:0,他引:7  
研究了用聚苯乙烯废料为原料,经过硝化氧化制造具有高附加值的精细化工产品-对硝基苯甲酸。探讨了影响对硝基苯甲酸产率的因素,如硝酸的浓度和用量,压力,反应时间及催化剂用量等。结果表明,在优化条件下对硝基苯甲酸产率达52%,产品纯度为99%。  相似文献   

13.
针对膜蒸馏法处理石化反渗透浓水的膜面污染物进行了分析及清洗工艺优化研究。在反渗透浓水温度为73℃、渗透侧真空度为-0.093 MPa的条件下进行膜蒸馏实验,实验后期膜通量衰减迅速,脱盐率基本保持在99.5%以上,产水p H基本稳定在6.5~7.0。膜面污染物的SEM表征结果显示,膜蒸馏的膜面污染主要为碳酸钙、硅酸钙、氢氧化镁结垢污染和氯化钠、氯化钾等盐类结晶污染。实验结果表明:分别以盐酸和去离子水为清洗液静态浸泡清洗污染膜时,污染物的去除效果最好,Na OH溶液次之,草酸最差;分别采用盐酸和去离子水动态清洗污染膜,膜通量和脱盐率均能恢复到初始水平,随运行时间的延长,经去离子水清洗后膜的膜通量出现衰减。  相似文献   

14.
左银虎 《化工环保》2017,37(3):371-380
利用二苯碳酰二肼显色,Triton X-100-正辛醇浊点萃取,建立了一种分光光度法测定水中Cr(Ⅵ)的新方法,并探讨了不同测定条件对测定效果的影响。优化后的测定条件为(总体积50 mL)1 mol/L稀硫酸加入量1.0mL、2 g/L二苯碳酰二肼溶液加入量1.5 mL、10 g/L Triton X-100溶液加入量1.5 mL、3 g/L苯甲酸溶液加入量4.0mL、正辛醇加入量5.0 mL。Cr(Ⅵ)质量浓度在0~20μg/L范围内符合朗伯-比尔定律,线性回归方程的相关系数为0.995 5。该方法应用于水样中痕量Cr(Ⅵ)的测定,相对标准偏差小于2.5%,加标回收率为95.7%。  相似文献   

15.
Polylactic acid (PLA) is a hydrolytically degradable aliphatic polyester, and water vapor permeability may have a significant influence on the rate of degradation. A method is devised to use bags prepared from PLA films and filled with molecular sieves to determine the water vapor permeability in the polymer, its copolymers with caprolactone, and blends with polyethylene glycol. The “solution-diffusion” model is used to determine the permeability parameters. These include the solubility coefficient,S, a measure of the equilibrium water concentration available for hydrolysis and the diffusion coefficient,D, which characterizes the rate of water vapor diffusion into the film under specific conditions. Values ofS andD at 50‡C and 90% relative humidity ranged from 400 × 10-6 to 1000 × 10-6 cm3 (STP)/(cm3 Pa) and 0.20 × 10-6 to 1.0 × 10-6 cm2/s, respectively. TheS andD coefficients were also measured at 20 and 40‡C and compared to those of other polymers. The degree of crystallinity was found to have little influence on the measured permeability parameters. The heat of sorption, δHS, and the activation energy of diffusion, ED, were used to show that the permeability process is best described by the “water cluster” model for hydrophobic polymers. Finally, the diffusion coefficient is used to compare the rate of water diffusion to the rate of water consumption by ester hydrolysis. Results indicate that hydrolytic degradation of PLA is reaction-controlled.  相似文献   

16.
采用液膜萃取—酸析沉降—络合萃取组合工艺对有机磷阻燃剂生产废水进行预处理.最佳工艺条件为:液膜萃取时,液膜油相(表面活性剂与煤油的混合液)与内水相(H2SO4溶液)的体积比2∶1、乳化液膜与废水的体积比1∶8、废水pH 13.0,硫酸体积分数10%、煤油中表面活性剂质量浓度30 g/L、液膜萃取时间 15 min;酸析沉降时,废水pH l.0,酸析沉降时间30 min;络合萃取时,络合萃取剂(烷基叔胺N235与煤油的混合液)中烷基叔胺N235体积分数30%,络合萃取剂与废水的体积比1∶4,废水pH l.0,络合萃取时间30 min.在此最佳处理条件下,废水COD总去除率可达93%,吡啶去除率达99.9%以上,总磷去除率可达97%,BOD5/COD提高至0.32,有利于后续生化处理.  相似文献   

17.
张兵  王颖  吴永红  赵薇 《化工环保》2013,33(4):349-353
以聚丙烯腈为原料制备了荷正电纳滤膜。分别采用热失重分析、FTIR、SEM对膜表面官能团及膜微观形貌进行了表征。考察了聚乙二醇添加剂、料液中氯化钙质量浓度、渗透侧流速等制备条件和操作条件对溶液中氯化钙去除率的影响。实验结果表明:以聚丙烯腈为原料、不添加聚乙二醇制备荷正电纳滤膜,在料液中氯化钙质量浓度为45mg/L、渗透侧流量为0.160mL/s的条件下,钙离子去除率可达96.0%;经蒸馏水冲洗再生后,该膜对钙离子去除率仍可达94.0%。  相似文献   

18.
将平板陶瓷膜组成膜组件对烟气水分和余热进行回收,考察了烟气的温度、相对湿度、流速和冷却水温度等参数对膜组件水热回收性能的影响。在实验工况下,水通量和水回收效率随着烟气温度、烟气相对湿度的增加和冷却水温度的降低而上升;水通量随着烟气流速的加快而上升,水回收效率随着烟气流速的加快先上升后降低;膜组件的水通量和水回收效率最高分别可达22.0 kg/(m2·h)和36.3%。平板陶瓷膜回收的热量主要来自烟气潜热,烟气潜热换热量与水通量呈正相关变化趋势。在实验工况下,平板陶瓷膜组件的总传热系数最高为412 W/(m2·℃),高于多通道管式陶瓷膜和单通道管式陶瓷膜。  相似文献   

19.
对压水堆电厂含硼酸废水的来源和特点进行了分析,讨论了化学沉淀法、离子交换法、膜分离法等硼酸脱除技术的原理和优缺点,在对各种方法进综合比较的基础上,展望了压水堆电厂硼酸脱除技术的发展趋势.  相似文献   

20.
As the number of leaking underground fuel tank sites with methyl tertiary butyl ehter (MTBE) contamination continues to grow, there is a need to develop cost-effective solutions for treatment of soil and water contamination. MTBE poses special challenges because of its physicochemical properties, in particular high solubility and low Henry's constant, low affinity for sorption, and very slow rate of microbial degradation. Advanced oxidation processes tend to generate undesirable by-products. Based on laboratory studies with hollow fiber membranes (HFM), a field-scale unit was constructed and tested at a number of sites, to determine the effectiveness of this technology in dealing with MTBE contamination. In addition, to treat the soil contamination, the HFM unit was coupled with a Spray Aeration Vapor Extraction (SAVE) unit, which is based on an internal combustion engine. The engine provides the means to treat soil vapors, as well as organic vapors from the spray aeration and HFM units. The overall treatment objectives of 5μg/l for MTBE and 1 μg/l for benzene were achieved with a treatment train consisting of an ion exchange unit, a spray aeration system, a hollow fiber membrane module and two granular activated carbon (GAC) units, for flowrates ranging from 3.8 to 30 l/min (1 to 8 gal/min). The ion exchange unit sewed to reduce water hardness and avoid scaling in the subsequent treatment units, extending the run-time of the entire system. Overall removal efficiencies for the spray aeration system and hollow fiber membrane module ranged from 85 to over 99 percent. High removal efficiencies (> 97%) were obtained at elevated water temperatures (54°C) or lower flowrates (up to 11 l/min). The GAC units were used only to polish the effluent and meet the discharge requirements. Soil, water, and gas phases are treated with this system. Cost estimates are provided for similar treatment processes, for water flowrates up to 38 l/min (10 gal/min). © 1999 John Wiley & Sons, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号