首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fenton's pre-treatment of mature landfill leachate   总被引:20,自引:0,他引:20  
Lopez A  Pagano M  Volpe A  Di Pinto AC 《Chemosphere》2004,54(7):1005-1010
The aim of this study was to check the effectiveness of the Fenton's reagent (Fe2+ + H2O2 + H+) for the pre-treatment of a municipal landfill leachate with the objective of improving its overall biodegradability, evaluated in terms of BOD5/COD ratio, up to a value compatible with biological treatment. The leachate came from a municipal sanitary landfill located in southern Italy and the average values of its main parameters were: pH=8.2; COD=10,540 mgl(-1); BOD5=2,300 mgl(-1); TOC=3,900 mgl(-1); NH4-N=5210 mgl(-1); conductivity=45,350 microScm(-1); alkalinity=21,470 mgl(-1) CaCO3. The effect of initial pH value on the pre-treatment effectiveness was evaluated by titrating the amount of acidic by-products formed. The extent of leachate oxidation was monitored and controlled by both pH and redox potential measurements. The best operational conditions for achieving the desired goal (i.e., BOD5/COD> or =0.5) resulted: Fe2+=275 mgl(-1); H2O2=3,300 mgl(-1); initial pH=3; reaction time=2 h. At the end of the Fenton's pre-treatment, in order to permit a subsequent biological treatment, residual ferric ions were removed increasing the pH up to 8.5 by adding 3 gl(-1) of Ca(OH)2 and 3 mgl(-1) of a cationic polyelectrolyte, the latter as an aid to coagulation. This final step also resulted in a further modest removal of residual COD due to co-precipitation phenomena.  相似文献   

2.
A novel process for degradation of toluene in the gas-phase using heterogeneous gas-liquid photocatalytic oxidation has been developed. The degradation of toluene gas by photo-Fenton reaction in the liquid-phase has experimentally examined. The photo-Fenton reaction in the liquid-phase could improve the overall toluene absorption rate by increasing the driving force for mass transfer and as a result enhance the removal of toluene in the exhaust gas. The toluene concentrations in the inlet gas were varied in the range from 0.0968 to 8.69gm(-3) with initial hydrogen peroxide concentration of 400mgl(-1) and Fe dose of 5.0mgl(-1). It was found that toluene in the inlet gas was almost completely dissolved into water and degraded in the liquid-phase for the inlet toluene gas concentration of less than 0.42gm(-3). The dynamic process of toluene gas degradation by the photo-Fenton reaction providing information for reaction kinetics and mass transfer rate was examined. Toluene removal kinetic analysis indicated that photo-Fenton degradation was significantly affected by H(2)O(2) concentration. The experimental results were satisfactorily described by the predictions simulated using the simplified tanks-in-series model combined with toluene removal kinetic analysis. The present results showed that the proposed chemical absorption process using the photo-Fenton heterogeneous gas-liquid photocatalytic oxidation is very effective for degradation of volatile organic gases.  相似文献   

3.
Catalkaya EC  Kargi F 《Chemosphere》2007,69(3):485-492
Advanced oxidation of diuron in aqueous solution by Fenton's reagent using FeSO(4) as source of Fe(II) was investigated in the absence of light. Effects of operating parameters namely the concentrations of pesticide (diuron), H(2)O(2) and Fe(II) on oxidation of diuron was investigated by using Box-Behnken statistical experiment design and the surface response analysis. Diuron oxidation by the Fenton reagent was evaluated by determining the total organic carbon (TOC), diuron, and adsorbable organic halogen (AOX) removals. Concentration ranges of the reagents resulting in the highest level of diuron oxidation were determined. Diuron removal increased with increasing H(2)O(2) and Fe(II) concentrations up to a certain level. Diuron concentration had a more profound effect than H(2)O(2) and Fe(II) in removal of diuron, TOC and AOX from the aqueous solution. Nearly complete (98.5%) disappearance of diuron was achieved after 15min reaction period. However, only 58% of diuron was mineralized after 240min under optimal operating conditions indicating formation of some intermediate products. Optimal H(2)O(2)/Fe(II)/diuron ratio resulting in the maximum diuron removal (98.5%) was found to be 302/38/20 (mgl(-1)).  相似文献   

4.
Wang A  Qu J  Liu H  Ge J 《Chemosphere》2004,55(9):1189-1196
A new wastewater treatment technology--electrokinetic-electrooxidation process (EK-EO process) is developed in this paper. The EK-EO process can take advantage of both electrooxidation on the anode surface and the electrokinetic process of anionic impurities under an electric field, which can enhance the TOC removal in electrolysis process. The degradation of an anionic azo dye Acid Red 14 (AR14) was experimentally investigated. It was found that under an electric field AR14 could be migrated into anode compartment and be efficiently mineralized. After 360 min electrolysis of 100 mgl(-1) AR14 solutions at 4.5 mAcm(-2), complete discoloration was observed in both cathode and anode compartment. About 60% TOC was electromigrated from cathode compartment to anode compartment, and more than 25 mgl(-1) TOC was abated in anode compartment. A possible degradation mechanism of AR14 by EK-EO process was proposed. Additionally, the effect of current density, recycling flux, and electrolyte concentration on the EK-EO degradation of AR14 was also investigated.  相似文献   

5.
The photo-Fenton process using potassium ferrioxalate as a mediator was investigated for the photodegradation of dichloracetic acid (DCA) and 2,4-dichlorophenol (DCP) in aqueous medium using solar light as source of irradiation. The influence of the solution depth, the light intensity and the effect of stirring the solution during irradiation process were evaluated using DCA as a model compound. A negligible influence of stirring the solution was observed when the concentration of ferrioxalate (FeOx) was 0.8 mM and solution depth was 4.5 or 14 cm. The optimum FeOx concentration determined for solution depths between 4.5 and 14 cm was 0.8 mM considering total organic carbon (TOC) removal during DCA irradiation. The high efficiency of the photo-Fenton process was demonstrated on summer days, when only 10 min of exposition (around noon) were sufficient to completely destroy the organic carbon of a 1.0 mM DCA solution in the presence of 0.8 mM FeOx and 6.0 mM H2O2 using a solution depth of 4.5 cm. It was observed that the photodegradation efficiency increases linearly with the solar light intensity up to values around 15 Wm(-2) but this linear relationship does not hold above this value showing a square root dependence. The photodegradation of a solution of DCP/FeOx showed a lower TOC removal rate than that observed for DCA/FeOx, achieving approximately 90% after 35 min irradiation under 19 W m(-2), while under this light intensity, the same TOC removal of DCA/FeOx was achieved in only 10 min irradiation.  相似文献   

6.
Treatment of trinitrotoluene by crude plant extracts   总被引:2,自引:0,他引:2  
Crude plant extract solutions (spinach and parrotfeather) were prepared and spiked with 2,4,6-trinitrotoluene (TNT) (20 mgl(-1)). 90-h TNT removal by these solutions was compared to controls. Spinach and parrotfeather extract solutions removed 99% and 50% of the initial TNT, respectively; TNT was not eliminated in the controls or in extract solutions where removal activity was deactivated by boiling. A first-order removal constant of 0.052 h(-1) was estimated for spinach extract solutions treating 20 mgl(-1) TNT concentrations, which compared favorably to intact plant removal. Concentration variation was described by Michaelis-Menton kinetics. Detectable TNT degradation products represented only a fraction of the total TNT transformed, and the transformation favored the formation of 4-aminodinitrotoluene. The results indicated that crude plant extracts transform TNT, without the presence of the live plant.  相似文献   

7.
INTENTION, GOAL, SCOPE, BACKGROUND: Since the intermediate products of some compounds can be more toxic and/or refractory than the original compund itself, the development of innovative oxidation technologies which are capable of transforming such compounds into harmless end products, is gaining more importance every day. Advanced oxidation processes are one of these technologies. However, it is necessary to optimize the reaction conditions for these technologies in order to be cost-effective. OBJECTIVE: The main objectives of this study were to see if complete mineralization of 4-chlorophenol with AOPs was possible using low pressure mercury vapour lamps, to make a comparison of different AOPs, to observe the effect of the existence of other ions on degradation efficiency and to optimize reaction conditions. METHODS: In this study, photochemical advanced oxidation processes (AOPs) utilizing the combinations of UV, UV/H2O2 and UV/H2O2/Fe2+ (photo-Fenton process) were investigated in labscale experiments for the degradation and mineralization of 4-chlorophenol. Evaluations were based on the reduction of 4-chlorophenol and total organic carbon. The major parameters investigated were the initial 4-chlorophenol concentration, pH, hydrogen peroxide and iron doses and the effect of the presence of radical scavengers. RESULTS AND DISCUSSION: It was observed that the 4-chlorophenol degradation efficiency decreased with increasing concentration and was independent of the initial solution pH in the UV process. 4-chlorophenol oxidation efficiency for an initial concentration of 100 mgl(-1) was around 89% after 300 min of irradiation in the UV process and no mineralization was achieved. The efficiency increased to > 99% with the UV/H2O2 process in 60 min of irradiation, although mineralization efficiency was still around 75% after 300 min of reaction time. Although the H2O2/4-CP molar ratio was kept constant, increasing initial 4-chlorophenol concentration decreased the treatment efficiency. It was observed that basic pHs were favourable in the UV/H2O2 process. The results showed that the photo-Fenton process was the most effective treatment process under acidic conditions. Complete disappearance of 100 mgl(-1) of 4-chlorophenol was achieved in 2.5 min and almost complete mineralization (96%) was also possible after only 45 min of irradiation. The efficiency was negatively affected from H2O2 in the UV/H2O2 process and Fe2+ in the photo-Fenton process over a certain concentration. The highest negative effect was observed with solutions containing PO4 triple ions. Required reaction times for complete disappearance of 100 mgl(-1) 4-chlorophenol increased from 2.5 min for an ion-free solution to 30 min for solutions containing 100 mgl(-1) PO4 triple ion and from 45 min to more than 240 min for complete mineralization. The photodegradation of 4-chlorophenol was found to follow the first-order law. CONCLUSION: The results of this study showed that UV irradiation alone can degrade 4-CP, although at very slow rates, but cannot mineralize the compound. The addition of hydrogen peroxide to the system, the so-called UV/H2O2 process, significantly enhances the 4-CP degradation rate, but still requires relatively long reaction periods for complete mineralization. The photo-Fenton process, the combination of homogeneous systems of UV/H2O2/Fe2+ compounds, produces the highest photochemical elimination rate of 4-CP and complete mineralization is possible to achieve in quite shorter reaction periods when compared with the UV/H2O2 process. RECOMMENDATIONS AND OUTLOOK: It is more cost effective to use these processes for only purposes such as toxicity reduction, enhancement of biodegradability, decolorization and micropollutant removal. However the most important point is the optimization of the reaction conditions for the process of concern. In such a case, AOPs can be used in combination with a biological treatment systems as a pre- or post treatment unit providing the cheapest treatment option. The AOP applied, for instance, can be used for toxicity reduction and the biological unit for chemical oxygen demand (COD) removal.  相似文献   

8.
The purpose of this research was to study the fate and toxicity of triclosan (TCS) in activated sludge systems and to investigate the role of biodegradation and sorption on its removal. Two continuous-flow activated sludge systems were used; one system was used as a control, while the other received TCS concentrations equal to 0.5 and 2mgl(-1). At the end of the experiment, 1mgl(-1) TCS was added in the control system to investigate TCS behaviour and effects on non-acclimatized biomass. For all concentrations tested, more than 90% of the added TCS was removed during the activated sludge process. Determination of TCS in the dissolved and particulate phase and calculation of its mass flux revealed that TCS was mainly biodegraded. Activated sludge ability to biodegrade TCS depended on biomass acclimatization and resulted in a mean biodegradation of 97%. Experiments with batch and continuous-flow systems revealed that TCS is rapidly sorbed on the suspended solids and afterwards, direct biodegradation of sorbed TCS is performed. Regarding TCS effects on activated sludge process, addition of 0.5mgl(-1) TCS on non-acclimatized biomass initially deteriorated ammonia removal and nitrification capacity. After acclimatization of biomass, nitrification was fully recovered and further increase of TCS to 2mgl(-1) did not affect the performance of activated sludge system. The effect of TCS on organic substrate removal was minor for concentrations up to 2mgl(-1), indicating that heterotrophic microorganisms are less sensitive to TCS than nitrifiers.  相似文献   

9.
The removal of radiocontrast agent diatrizoic acid (DIA) from water was performed using photo-Fenton (PF) process. First, the effect of H2O2 dosage on mineralization efficiency was determined using ultraviolet (UV) irradiation. The system reached a maximum mineralization degree of 60 % total organic carbon (TOC) removal at 4 h with 20 mM initial H2O2 concentration while further concentration values led to a decrease in TOC abatement efficiency. Then, the effect of different concentrations of Fenton’s reagents was studied for homogeneous Fenton process. Obtained results revealed that 0.25 mM Fe3+ and 20 mM H2O2 were the best conditions, achieving 80 % TOC removal efficiency at 4 h treatment. Furthermore, heterogeneous PF treatment was developed using iron-activated carbon as catalyst. It was demonstrated that this catalyst is a promising option, reaching 67 % of TOC removal within 4 h treatment without formation of iron leachate in the medium. In addition, two strategies of enhancement for process efficiency are proposed: coupling of PF with electro-Fenton (EF) process in two ways: photoelectro-Fenton (PEF) or PF followed by EF (PF-EF) treatments, achieving in both cases the complete mineralization of DIA solution within only 2 h. Finally, the Microtox tests revealed the formation of more toxic compounds than the initial DIA during PF process, while, it was possible to reach total mineralization by both proposed alternatives (PEF or PF-EF) and thus to remove the toxicity of DIA solution.  相似文献   

10.
Characterization of Cr ion exchange with hydrotalcite   总被引:2,自引:0,他引:2  
Terry PA 《Chemosphere》2004,57(7):541-546
Experiments were performed to characterize the removal of chromium from water with uncalcined hydrotalcite, a clay mineral ion exchange media. The process was characterized as a function of pH, temperature, contact time, and both Cr and hydrotalcite concentrations. A Freundlich isotherm, used to describe adsorption equilibria, was used as a model and Freundlich constants were determined. The kinetics of the ion exchange reaction were also modeled using a pseudo-first order reaction rate. Finally, an equilibrium stage process was modeled with sequential batch separations to determine if hydrotalcite ion exchange could reduce aqueous Cr levels to below the EPA limit of 0.1mgl(-1). It was shown that the process is highly pH dependent, only yielding significant removals at pH levels between 2.0 and 2.1. While hydrotalcite concentration, Cr concentration, and time did effect the ion exchange, temperature was not found to be a factor. Under optimal conditions, maximum removals of greater than 95% were achieved. Finally, sequential batch tests performed on initial Cr solutions ranging from 5mgl(-1) to 40mgl(-1), demonstrated that the water could be purified to a level that was not statistically different than the EPA limit, thus demonstrating the applicability of hydrotalcite ion exchange.  相似文献   

11.
The present study deals with the biodegradation of catechol through co-metabolism with glucose in aqueous solution as primary substrate in an upflow anaerobic sludge blanket (UASB) reactor. Batch studies indicated that the 1000mgl(-1) glucose concentration was sufficient to cometabolize and degrade catechol in an aqueous solution up to a concentration of 1000mgl(-1). The reactor operated at 35+/-2 degrees C, and at a constant hydraulic retention time of 8h with a gradual stepwise increase in catechol concentration from 100 to 1000mgl(-1) along with glucose as a cosubstrate. The results showed that the catechol was successfully mineralized in an UASB reactor in which microbial granulation was achieved with only glucose as the substrate. The reactor showed > or = 95% COD removal efficiency with 500-1000mgl(-1)catechol concentration in the feed and a glucose concentration of 1500mgl(-1) as a cosubstrate. Similar efficiency was obtained at a constant catechol concentration of 1000mgl(-1) with 500-1000mgl(-1) glucose concentration. Once the reactor got acclimatized with catechol, higher concentrations of catechol can be mineralized with a minimum amount of glucose as the cosubstrate without affecting the performance of the UASB reactor.  相似文献   

12.
Photo-oxidation of cork manufacturing wastewater   总被引:7,自引:0,他引:7  
Several photo-activated processes have been investigated for oxidation of a cork manufacturing wastewater. A comparative activity study is made between different homogeneous (H2O2/UV-Vis and H2O2/Fe2+/UV-Vis) and heterogeneous (TiO2/UV-Vis and TiO2/H2O2/UV-Vis) systems, with degradation performances being evaluated in terms of total organic carbon (TOC) removal. Results obtained in a batch photo-reactor show that photo-catalysis with TiO2 is not suitable for this kind of wastewater while the H2O2/UV-Vis oxidation process, for which the effect of some operating conditions was investigated, allows to remove 39% of TOC after 4 h of operation (for C(H2O2)=0.59 M, pH=10 and T=35 degrees C). The combined photo-activated process, i.e., using both TiO2 and H2O2, yields an overall TOC decrease of 46% (for C(TiO2)=1.0 gl(-1)). The photo-Fenton process proved to be the most efficient, proceeds at a much higher oxidation rate and allows to achieve 66% mineralization in just 10 min of reaction time (for C(H2O2)=0.31 M, T=30 degrees C, Fe2+:H2O2=0.12 (mol) and pH=3.2).  相似文献   

13.
The photocatalytic removal kinetics of fenitrothion at a concentration of 0.5mgl(-1) in pure and natural waters were investigated in Fe(III)/H2O2/UV-Vis, Fe(III)/UV-Vis and H2O2/UV-Vis oxidation systems, with respect to decreases in fenitrothion concentrations with irradiation time using a solar simulator. Fenitrothion concentrations were determined by HPLC analysis. Furthermore, total mineralization of fenitrothion in these systems was evaluated by monitoring the decreases in DOC concentrations with solar simulator irradiation time by TOC analysis. It was shown that the degradation rate of fenitrothion was much faster in the Fe(III)/H2O2/UV-Vis system than the Fe(III)/UV-Vis and H2O2/UV-Vis systems in both pure and river waters. Consequently, the mineralization rate of fenitrothion was much faster in the Fe(III)/H2O2/UV-Vis system than in the other two systems. The high *OH generation rate measured in the Fe(III)/H2O2/UV-Vis system was the key to faster degradation of fenitrothion. Increases in the concentrations of H2O2 and Fe led to better final degradation of fenitrothion. These results suggest that the photo-Fenton reaction (Fe(III)/H2O2/UV-Vis) system is likely to be an effective method for removing fenitrothion from contaminated natural waters.  相似文献   

14.
Chitose N  Ueta S  Seino S  Yamamoto TA 《Chemosphere》2003,50(8):1007-1013
Aqueous phenol solutions containing TiO(2) nanoparticles were irradiated with ultraviolet (UV), gamma-ray and electron beams. Organic compounds were fully removed by each type of radiation in the presence of the particles. The absorbed energy of the ionizing radiation (gamma-ray and electron beams) needed for removal was much lower than that of UV photocatalysis. Phenol was decomposed by the ionizing radiation in the absence of the nanoparticles and the addition of TiO(2) had no significant effect on phenol decomposition rate. Instead, total organic carbon (TOC) removal using the ionizing radiation was accelerated drastically by TiO(2). It is suggested that TiO(2) particles affect the intermediate compounds produced through the decomposition of phenol. The amount of removed TOC per absorbed energy were compared in the absence and the presence of TiO(2) nanoparticles. Radiolysis with the nanoparticles showed consistently high rate and high efficiency of TOC removal.  相似文献   

15.
Intention, Goal, Scope, Background The effect of chloride concentration and pH on the UV oxidation systems was examined. Phenol and methanol were used as organic substances. The treatment of these chemicals by UV oxidation using a newly developed lab scale pretest UV-Free Surface Reactor (UV-FSR) with and without Cl– addition at different pH values, is evaluated. Results of this study indicated that the Cl– concentration of the water and the chemical structure of the substances is more important than the pH of the water. There was no AOX at the beginning of the experiments, but a de-novo synthesis of AOX was observed during the batch experiments. This is caused by the high chloride content of the wastewaters. It can be supposed that OHradicals oxidize some chloride-ions to form chlorine, which further reacts with organic compounds. During the treatment, these AOX compounds which are produced from the beginning of the reaction are destroyed again. Evaluations of these experiments were done according to TOC and AOX results. Approximately 80% and 99% TOC removal efficiencies were obtained for the treatment of Phenol and Methanol-containing wastewaters, respectively. Objective In the literature, there are no relevant publications concerning the AOX formation of wastewater by wet oxidation- iron catalysed or by application of UV. For that reason, the main objectives of this study were: 1. to see the influence of chloride concentration and pH on the AOXde-novo formation with newly developed UV-Free Surface Reactor (UV-FSR), 2. to make a comparison of different AOPs, 3. to observe the effect of the chloride concentration on the TOC degradation efficiency, 4. to optimise reaction conditions. Methods In synthetic wastewaters, Methanol (CH3OH) and Phenol (C6H5 OH) are used as pollutants. The concentration of each substance was 1000 mg/l and COD values were calculated theoretically. The H2O2 addition was calculated according to the COD with a convenient stoichiometric factor (e.g. 1). During experiments, the pH was always kept constant with the addition of either 25% H2SO4 or 33% NaOH depending on the experimental conditions. Each substance was treated with the addition of 1000 mg/l Cl–, 10000 mg/l Cl– and without Cl– addition at pH 3, pH 7 and pH 10, respectively. NaCl was used as a Cl– source. Adsorbable Organic Halogenides (AOX) were determined using a TOX analyser (European Standard EN 1485 H 14, 1996). TOC measurements were carried out using an Elementar High TOC Analyzer equipped with an auto sampler. The H2O2 concentration was measured according to German Standard Methods (DIN 38409, Part 15, 1987). Results and Discussion The first step was to determine the effect of pH on the AOX formation in the process. Therefore, experiments were carried out at three different pHs: acidic (pH 3), neutral (pH 7) and basic (pH 10) conditions at a constant initial Methanol concentration of 1000 mg/l and a hydrogen peroxide concentration of 3185 mg/l (1 x stoichiometric). All results were evaluated according to applied pH. At these conditions, the amount of H2O2 (53 ml / 10 l) concentration was nearly zero after 1 hour batch treatment of Methanol. There was no AOX at the beginning of the experiments, but the AOX value increased after 6–18 min. At the end of 1 hour batch treatment this produced AOX was treated again. The maximum AOX production was obtained with the addition of 10000 mg/l Cl–, whereas there is no AOX production during the experiment when Cl– was not used. In all studies, however, TOC values decreased to almost zero after 1 hour batch treatment. After the experiments with Methanol, Phenol treatment was carried out at different pHs as a second experiment. pH was kept constant with the addition of either H2SO4 or NaOH depending on the experimental conditions. During experiments with Phenol, the colour of the water changed from colourless to a yellowish- red. After 1 hour treatment, the colour of the water was red. Therefore, these experiments were continued until the water became colourless again, and this took about 5 hours. Although there was no AOX at the beginning of the experiments, it increased after 30 min to 1 hour oxidation with the addition of 1000 mg/l Cl– and 10000 mg/l Cl–. There was no AOX production during the experiments when Cl– was not added. At the end of 5 hours of treatment, formed AOX was degraded and the TOC concentration decreased from 766 mg/l to approximately 200 mg/l. Conclusion. These experiments of this study showed that the effects of Cl– concentration of the water and the chemical structure of the substances is more than that of the pH on the AOX formation. During the batch experiments, a de-novo synthesis of AOX was observed very impressively due to the high chloride content of the wastewaters. It can be implied that OH-radicals oxidize some chloride-ions to form chlorine, which further reacts with organic compounds so that AOXde-novo is formed. At the end of the reaction times these AOX compounds are also destroyed. Recommendation and Outlook It is more cost effective to use these processes for only purposes such as toxicity reduction, enhancement of biodegradability, decolourisation and removal of micropollutants. However, the most important point is the optimization of the reaction conditions for the process of concern. The AOP applied can be used, for instance, for AOX reduction and TOC removal of industrial wastewaters.  相似文献   

16.
Peng Y  Fu D  Liu R  Zhang F  Liang X 《Chemosphere》2008,71(5):990-997
A combination of ferric chloride and sodium nitrite significantly improved the wet oxidation of the azo dye Acid Orange 7 (AO7) in acid aqueous media (pH 2.6) under moderate conditions (T=150 degrees C; oxygen pressure=0.5 MPa). To evaluate the catalytic system, wet oxidation of AO7 was carried out at temperatures between 90 and 150 degrees C and oxygen pressures ranging from 0.1 to 0.5 MPa. The effect of initial solution pH from 2.6 to 11.4 and the amount of catalyst on the degradation of AO7 were also investigated. AO7 initial concentration was kept 200 mg L(-1). The degradation process was monitored by UV-visible spectroscopy, HPLC, IC (ion chromatography), GC-MS and TOC analysis. At 150 degrees C and 0.5 MPa oxygen pressure, 56% TOC was removed after 4h of treatment, while no obvious TOC removal were achieved without catalyst at the same experimental condition. The main degradation products were some small organic acids: formic acid, acetic acid, pyruvic acid, oxalic acid, succinic acid (identified and quantified by IC) and phthalic acid (identified by GC-MS).  相似文献   

17.
The photo-Fenton reaction of an organophosphorus insecticide, dimethoate (O,O-dimethyl methylcarbamoylmethyl phosphorodithioate), was studied by following the identification and determination of the decomposition products and the total carbon removal rate. The reactions were performed in a batch recycle reactor, at room temperature, using UV radiation, H2O2 as oxidant, and FeCl3 x 6H2O as catalyst. The oxidation results were determined with a total organic carbon (TOC) analyzer and ion chromatography. The presence of reaction products was identified by gas chromatography-mass spectrometry (GC-MS). Apart from the sulfate, phosphate, and ammonium ions, the presence of dimethyl phosphite, N-methyl-acetamide, and formic acid was also detected. Excess of H2O2 concentration did not influence the reaction rate. The expression for the total carbon removal was assessed and the TOC removal rate constants were calculated.  相似文献   

18.
Chen WS  Juan CN  Wei KM 《Chemosphere》2005,60(8):1072-1079
Fenton's reagent, UV/H2O2 and UV/Fenton's reagent were employed to mineralize dinitrotoluene (DNT) isomers and 2,4,6-trinitrotoluene (TNT) of spent acid in toluene nitration process. The bench-scale experiments were conducted to elucidate the influence of various operating variables on the performance of removal of total organic compounds (TOC) from spent acid, including reaction temperature, concentration of ferrous ion and H2O2 dosage. It is remarkable that organic compounds were completely mineralized by Fenton oxidation, of which removal efficiency is superior to that of UV/H2O2. Nevertheless, it makes slight difference between Fenton oxidation and UV/Fenton oxidation. According to the spectra identified by gas chromatograph/mass spectrometer (GC/MS), it is proposed that oxidative degradation of DNT isomers leads to o-, m-, p-mononitrotoluene (MNT) and 1,3-dinitrobenzene respectively. Besides, the oxidation of 2,4,6-TNT gives the 1,3,5-trinitrobenzene intermediate. Apparently, Fenton oxidation is promising for purification of spent acid industrially.  相似文献   

19.
Activated carbon adsorption and chemical oxidation followed by activated carbon adsorption of resorcinol in water has been studied. Three chemical oxidants have been used: hypochlorite, permanganate and Fenton's reagent. The influence of concentrations of resorcinol and activated carbon on adsorption removal rates has been investigated. Both isotherm and adsorption kinetics have been studied. Results are fit well by Freundlich isotherms and adsorption rates of resorcinol were found to follow a pseudo-second-order kinetic model. However, pyrogallol, an intermediate of resorcinol oxidation with permanganate and Fenton's reagent, showed an unfavourable isotherm type. At the conditions investigated, chemical oxidation allows slight reductions of TOC and intermediates formed were found to inhibit the adsorption rate of TOC in the case of permanganate and Fenton's reagent oxidation, likely due to formation of some polymer pyrogallol product. The adsorption process was found to be controlled by pore internal diffusion, which justifies the poor affinity of oxidation intermediates toward activated carbon since molecules of larger size should diffuse rapidly for the adsorption to be effective.  相似文献   

20.
Lai CL  Lin SH 《Chemosphere》2004,54(3):235-242
Treatment of copper chemical mechanical polishing (CMP) wastewater from a semiconductor plant by electrocoagulation is investigated. The CMP wastewater was characterized by high suspended solids (SS) content, high turbidity (NTU), chemical oxygen demand (COD) concentration up to 500 mgl(-1) and copper concentration up to 100 mgl(-1). In the present study, electrocoagulation was employed to treat the CMP wastewater with an attempt to simultaneously lower its turbidity, copper and COD concentrations. The test results indicated that electrocoagulation with Al/Fe electrode pair was very efficient and able to achieve 99% copper ion and 96.5% turbidity removal in less than 30 min. The COD removal obtained in the treatment was better than 85%, with an effluent COD below 100 mgl(-1). The effluent wastewater was very clear and its quality exceeded the direct discharge standard. In addition, sludge settling velocities after electrocoagulation were measured and the data were employed to verify the empirical sludge settling velocity models. Finally, the sludge settling characteristic data were also utilized to establish the relation between the solids flux (G) and the initial solids concentration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号