首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Efforts to reduce the energy needs to heat or cool dwellings have the potential to create new health hazards. Increases in indoor levels of radon and its progeny from the reduction in air exchange rates add a substantial radioactive burden to the general population. Other indoor pollutants reaching critical concentrations in homes with low air exchange rates are CO and NO2 from unvented combustion in gas stoves and heaters, tobacco smoke, and asbestos fibers. In addition, insulation materials and certain types of furniture may contribute the toxicant formaldehyde diffusing from foam injected walls or chipboard. Risk estimations using linear dose-response relationships show risk factors per kWh saved which are orders of magnitude greater than for a kWh produced by large power plants using coal, oil, gas, or uranium.  相似文献   

2.
Particulate and gaseous emissions from indoor combustion appliances and smoking can elevate the indoor concentrations of various pollutants. Indoor pollutant concentrations resulting from operating one of several combustion appliances, or from sidestream tobacco smoke, were measured in a 27-m3 environmental chamber under varying ventilation rates. The combustion appliances investigated were gas-fired cooking stoves, unvented kerosene-fired space heaters, and unvented natural-gas-fired space heaters. Results showed elevated levels of carbon dioxide, carbon monoxide, nitric oxide, nitrogen dioxide, formaldehyde, and suspended particles from one or more of the pollutant sources investigated. Our findings suggest that, of the sources examined in this study, nitrogen dioxide from combustion appliances and particles from sidestream cigarette smoke are the most serious contaminants of indoor air, if we use existing standards and guidelines as the criteria. An emission rate model was used to quantify the strengths of the pollutant sources, which are reported in terms of the mass of pollutant emitted per energy unit of fuel consumed (in the case of gas and kerosene appliances) and per mass of tobacco combusted (in the case of smoking).  相似文献   

3.
Indoor air quality in animal buildings is very important to the health of agricultural workers and animals. Carbon dioxide (CO2) and ammonia (NH3) are two of the most important pollutants in pig houses. Four tests were conduced in a mechanically ventilated pig house to study release behaviors of CO2 and NH3 from liquid manure using impulse, pulse and step ventilation inputs. The CO2 and NH3 concentrations were sampled in the exhaust chimney and measured with a CO2 monitor and a NOx analyzer, respectively. The ventilation rate was measured with a ventilation rate sensor in the chimney. A new phenomenon, characterized by a delayed dynamic response of NH3 release to the high ventilation inputs as compared with the response of CO2 release, was encountered. A new CO2 factor was identified as the cause of the delayed NH3 response. An original concept of Carbon-dioxide Accelerated Ammonia Release (CAAR) was developed. It explained that, at the initial stage of gas release induced by the high ventilation, the high release of CO2 gradually raised the pH in the surface manure. The increased pH accelerated the release of NH3. The higher release of NH3 had a negative feedback to the pH. The effects of CO2 and NH3 releases on the pH finally reached a dynamic equilibrium. The NH3 release under the dynamic equilibrium was greatly accelerated compared to that under initial conditions.  相似文献   

4.
Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although 222Rn concentrations in Sivas were quite low in relation with the allowable limits, they are higher than the average of Turkey. Indoor and soil gas 222Rn concentration distribution maps were prepared seperately and these maps were applied onto the surface geological map. In this way, both surveys were correlated with the each other and they were interpreted in comparison with the answers of questionnaire and the geological setting of the Sivas centrum and the vicinity.  相似文献   

5.
Concentrations of airborne radon ranging from 0.05 to 135 pCi/L were found in houses in Maine. Tracketch cups were placed in five positions for 100 houses to determine integrated average radon concentrations over the period October 1980–May 1981. To investigate the association between elevated radon concentrations in well water and the indoor airborne radon concentrations, the radon in the water supplies of these houses was measured by liquid scintillation. Monitors of airborne radon, recording in intervals of 10 min for periods of 5–7 days, were used for dynamic studies in 18 houses, determining the component of airborne radon associated with major water uses, such as showers, laundry, and dishwashing, which liberate radon in bursts. House residents kept logs noting the time of major water uses. For some of the houses, ventilation rates ranging from 0.3 to 2 air changes per hour were determined by analysis of the dynamic data. The component of airborne radon associated with water sources was found to vary inversely with ventilation rate and directly with waterborne radon concentration, with 0.8 ± 0.2 pCi Rn/L air per nCi Rn/L water at a ventilation rate of 1.0 air change per hour. The data are pertinent to a study which has revealed significant correlations between county averages, from the National Cancer Institute, or age-adjusted cancer mortality rates in Maine and average values of radon concentrations in water for the counties.  相似文献   

6.
Alternative and renewable fuels have numerous advantages compared with fossil fuels as they are renewable and biodegradable, besides providing food and energy security and foreign exchange savings and addressing environmental and socio-economic issues. Therefore, these renewable fuels can be used predominantly in compression ignition (CI) engines for transportation purposes and power generation applications. Today, the use of biomass-derived producer gas is more relevant for addressing rural power generation and is also a promising technique for controlling both NOx and soot emission levels. Although a producer gas–biodiesel-operated dual-fuel diesel engine exhibits lower performance, they are independent from the use of fossil fuels. The lower performance of the engine could be due to the slow-burning and lower calorific value of producer gas. For this purpose, exhaustive experiments on the use of Honge oil methyl ester (HOME)–producer gas in a dual-fuel CI engine were carried out for the improvement of its fuel efficiency. This paper presents the effect of the compression ratio (CR) on the performance, combustion and exhaust emission characteristics of a single-cylinder, four-stroke, direct injection stationary diesel engine operated using HOME and producer gas in a dual-fuel mode. The results indicated that the HOME–producer gas combination exhibited lower brake thermal efficiency (BTE) with comparable emission levels with the diesel–producer gas combination at different CRs. Comparative measures of BTE, peak pressure, pressure–crank angle variation, heat release rate, smoke opacity, and hydrocarbon (HC), carbon monoxide (CO) and nitric oxide (NOx) emission levels are presented and analysed.  相似文献   

7.
On 15 dates, 5000 measurements of carbon monoxide (CO) were made in downtown commercial settings in four California towns and cities (San Francisco, Palo Alto, Mountain View, and Los Angeles), using personal exposure monitoring (PEM) instruments. Altogether, 588 different commercial settings were visited, and indoor and outdoor locations were sampled at each setting. On 11 surveys, two CO PEM's were carried about 0.15–6 m apart, giving 1706 pairs of observations that showed good agreement: the correlation coefficient was r = 0.97 or greater, and the average difference was less than 1 ppm (μL/L) by volume. Of 210 indoor settings (excluding parking garages), 204 (97.1%) had average CO concentrations less than 9 ppm (μL/L); of 368 outdoor settings, 356 (96.7%) had average CO concentrations less than 9 ppm (μL/L). For a given date and commercial setting, CO concentrations were found to be relatively stable over time, permitting levels to be characterized by making only brief visits to each setting. The data indicate that most commercial settings experience CO concentrations above zero indoors, because CO tends to seep into buildings from vehicular emissions outside. Levels in these locations usually are not above 5 ppm (μL/L) and seldom are higher than the U.S. health-related ambient air quality standards for CO. However, indoor garages and buildings with attached indoor parking areas are exceptions and can experience relatively high CO concentrations.  相似文献   

8.
A sample of 58 occupied homes in Rochester, NY, most of which incorporated special builder-designed weatherization components, were studied to assess (1) the effectiveness of construction techniques designed to reduce air leakage; (2) the indoor air quality and air-exchange rates in selected airtight houses, and (3) the impact on indoor air quality of mechanical ventilation systems employing air-to-air heat exchangers. The “specific leakage area” was measured in each house using the fan pressurization technique. Houses built with polyethylene vapor barriers and joint-sealing were as a group 50% tighter than a similar group of houses without such components. Mechanical ventilation systems with air-to-air heat exchangers were installed in nine relatively airtight houses, some of which had gas stoves and/or tobacco smoking occupants. Air-exchange rates and indoor concentrations of radon (Rn), formaldehyde (HCHO), nitrogen dioxide (NO2), and humidity were measured in each house for 1-week periods with and without mechanical ventilation. More detailed measurements, including concentrations of carbon monoxide and inhalable particulates, were made in two of these houses by a mobile laboratory. In all nine houses, air-exchange rates were relatively low (0.2–0.5 ach) without mechanical ventilation, and yet indoor concentrations of Rn, HCHO, and NO2 were below existing guidelines. Mechanical ventilation systems were effective in further reducing indoor contaminant concentrations. We conclude that when contaminant source strengths are low, acceptable indoor air quality can be compatible with low air-exchange rates.  相似文献   

9.
Although United Kingdom (UK) Building Regulations applicable to houses constructed since 1992 in Radon Affected Areas address the health issues arising from the presence of radon in domestic properties and specify the installation of radon-mitigation measures during construction, no legislative requirement currently exists for monitoring the effectiveness of such remediation once construction is completed and the houses are occupied. To assess the relative effectiveness of During-Construction radon reduction and Post-Construction remediation, radon concentration data from houses constructed before and after 1992 in Northamptonshire, UK, a designated Radon Affected Area, was analysed. Post-Construction remediation of 73 pre-1992 houses using conventional fan-assisted sump technology proved to be extremely effective, with radon concentrations reduced to the Action Level, or below, in all cases. Of 64 houses constructed since 1992 in a well-defined geographical area, and known to have had radon-barrier membranes installed during construction, 11% exhibited radon concentrations in excess of the Action Level. This compares with the estimated average for all houses in the same area of 17%, suggesting that, in some 60% of the houses surveyed, installation of a membrane has not resulted in reduction of mean annual radon concentrations to below the Action Level. Detailed comparison of the two data sets reveals marked differences in the degree of mitigation achieved by remediation. There is therefore an ongoing need for research to resolve definitively the issue of radon mitigation and to define truly effective anti-radon measures, readily installed in domestic properties at the time of construction. It is therefore recommended that mandatory testing be introduced for all new houses in Radon Affected Areas.  相似文献   

10.
The measurement campaigns have been done in the rural community of Niska Banja, a spa town located in southern Serbia, to evaluate population exposure to natural radioactivity. After a screening survey in 200 houses, annual radon and thoron concentrations were measured in 34 houses, and in 2004 a detailed investigation was carried out at six houses with elevated indoor radon concentrations. The paper presents the results of these detailed measurements. The complementary techniques were applied to determine radon and thoron concentrations in indoor air, in soil gas, radon exhalation from soil, soil permeability, and indoor and outdoor gamma doses. Soil and water samples were collected and analysed in the laboratory. Indoor radon and thoron concentrations were found to be more than 1kBqm(-3) and 200Bqm(-3), respectively. Extremely high concentrations of soil-gas radon (>2000kBqm(-3)) and radon exhalation rates (1.5mBqm(-2)s(-1)) were observed. These results will be utilised to set up the methodology for a more systematic investigation.  相似文献   

11.
经济增长对资源消耗存在很大的依赖性,研究能源消费、碳排放与经济增长关系,可为经济增长方式转变和低碳城市建设提供重要科学依据。基于IPCC国家温室气体排放清单指南中的方法估算了无锡市能源消费碳排放,并建立“脱钩”模型探讨能源消费、碳排放与经济增长之间的关系。结果表明:(1)2000~2010年,无锡市碳排放从84335万t增加到2 52804万t,总量不断增加,但趋势有所减缓,且各县市碳排放特征差异显著;(2)无锡市碳排放与经济增长整体处于弱脱钩状态,且脱钩状态有不断增强的趋势,市区经济发展已不依赖于能源消费,朝着环境友好方向发展,江阴和宜兴节能减排压力仍然很大;(3)优化产业结构、调整工业结构和提高能源利用效率是改善无锡市能源消费、碳排放和经济增长关系的有效途径,各县市根据具体情况,侧重点有所不同  相似文献   

12.
This paper reviews the Regional Carbon Sequestration Partnerships (RCSP) concept, which is a first attempt to bring the U.S. Department of Energy's (DOE) carbon sequestration program activities into the "real world" by using a geographically-disposed-system type approach for the U.S. Each regional partnership is unique and covers a unique section of the U.S. and is tasked with determining how the research and development activities of DOE's carbon sequestration program can best be implemented in their region of the country. Although there is no universal agreement on the cause, it is generally understood that global warming is occurring, and many climate scientists believe that this is due, in part, to the buildup of carbon dioxide (CO(2)) in the atmosphere. This is evident from the finding presented in the National Academy of Science Report to the President on Climate Change which stated "Greenhouse gases are accumulating in Earth's atmosphere as a result of human activities, causing surface air temperatures and subsurface ocean temperatures to rise. Temperatures are, in fact, rising. The changes observed over the last several decades are likely mostly due to human activities, ...". In the United States, emissions of CO(2) originate mainly from the combustion of fossil fuels for energy production, transportation, and other industrial processes. Roughly one third of U.S. anthropogenic CO(2) emissions come from power plants. Reduction of CO(2) emissions through sequestration of carbon either in geologic formations or in terrestrial ecosystems can be part of the solution to the problem of global warming. However, a number of steps must be accomplished before sequestration can become a reality. Cost effective capture and separation technology must be developed, tested, and demonstrated; a database of potential sequestration sites must be established; and techniques must be developed to measure, monitor, and verify the sequestered CO(2). Geographical differences in fossil fuel use, the industries present, and potential sequestration sinks across the United States dictate the use of a regional approach to address the sequestration of CO(2). To accommodate these differences, the DOE has created a nationwide network of seven Regional Carbon Sequestration Partnerships (RCSP) to help determine and implement the carbon sequestration technologies, infrastructure, and regulations most appropriate to promote CO(2) sequestration in different regions of the nation. These partnerships currently represent 40 states, three Indian Nations, four Canadian Provinces, and over 200 organizations, including academic institutions, research institutions, coal companies, utilities, equipment manufacturers, forestry and agricultural representatives, state and local governments, non-governmental organizations, and national laboratories. These partnerships are dedicated to developing the necessary infrastructure and validating the carbon sequestration technologies that have emerged from DOE's core R&D and other programs to mitigate emissions of CO(2), a potent greenhouse gas. The partnerships provide a critical link to DOE's plans for FutureGen, a highly efficient and technologically sophisticated coal-fired power plant that will produce both hydrogen and electricity with near-zero emissions. Though limited to the situation in the U.S., the paper describes for the international scientific community the approach being taken by the U.S. to prepare for carbon sequestration, should that become necessary.  相似文献   

13.
Radon daughter levels have been monitored in 12,000 Swedish dwellings during the last two years. In 1979 the Swedish Government introduced temporary limits for the radon daughter concentration in dwellings. For existing buildings this limit is 400 Bq/m3 (0.11 WL). Two different methods were used to monitor the radon daughter concentration. The majority of the houses presented in this paper were monitored using a track-etch detector; some houses were tested using a filter sampling technique while the ventilation rate was determined. Close to 15% of the investigated houses have a radon daughter concentration higher than 400 Bq/m3. The majority of these houses were one-family houses. Almost 10% of this group has a concentration above 1000 Bq/m3 (0.27 WL). The results from this study show that the two most important sources for radon in buildings are building materials and the ground.  相似文献   

14.
In its evaluation of federal ambient air quality criteria for carbon monoxide (CO), the U.S. Environmental Protection Agency is seeking to identify the mechanisms of CO exposure and the populations at risk. The suitability of existing fixed-site monitoring networks to characterize population exposure is also being studied. This paper describes field measurements in two major metropolitan areas of CO exposure in the passenger sections of 1164 buses, taxis, and police cars. The objectives of the program were to identify high-CO vehicles and to elucidate the mechanisms for high passenger exposures. Vehicle fleets were initially screened with passive dosimeters and pump-driven personal samplers. Selected vehicles were then instrumented with portable electrochemical-cell continuous analyzers coupled to recorders. Principal CO sources and intrusion pathways were pinpointed by use of an inert tracer gas (SF6) detection system. Intrusion tests were made at idle and with the vehicles in motion. Fixed-station monitoring values were found to underpredict, in a nonuniform manner, out-of-vehicle CO exposures determined by the field measurements. In 58% of the 120 personal sampler readings for rides greater than eight hours, the EPA eight-hour ambient air quality standard for carbon monoxide (9 ppm) was exceeded.  相似文献   

15.
This paper proposes to use DEA models with undesirable outputs to construct the Malmquist index that can be use to investigate the dynamic changes of CO 2 emission performance.With the index,the authors have measured the CO 2 emission performance of 28 provinces and autonomous regions in China from 1996 to 2007;with the convergence theory and panel data regression model,the authors analyze the regional differences and the influencing factors.It is found that the performance of CO 2 emissions in China has been continuously improved mainly due to the technological progress,and the average improvement rate is 3.25%,with a cumulative improvement rate of 40.86%.In addition,the CO 2 emission performance varies across four regions.As a whole,the performance score of eastern China is the highest.The northeastern and central China has relatively lower performance scores,and the western China is relatively backward.The regional differences are decreasing,and the performance of CO 2 emissions is convergent.The influence of some factors on the performance of CO 2 emissions is significant,such as the level of economic development,the level of industrial structure,energy intensity,and ownership structure.The influence of some factors,such as opening-up to the outside world,on the performance of CO 2 emissions is not significant..  相似文献   

16.
The temperature is 56.5°C when acetone gas is rectified during the production of powdery phospholipid. If heat exchanger is added, heat energy that is reclaimed can be used by other heaters. On the basis of exchange hot water (51°C) 4m3 every minute, a factory with the productivity of powdery phospholipid being 10 ton a day can save 533.2 ton standard coal which is equivalent to 746.48 ton common coal. If this technique of saving energy and reducing emission could be widely used in correlative industries of all over the country, economic benefits will be prominent.  相似文献   

17.
Monitoring of radon, thoron and their daughter products was carried out in houses of Kumaun Himalaya, India using LR-115 plastic track detectors. The measurements were made in residential houses from June 1999 to May 2000 at a height of 2.5 m from ground level using a twin chamber radon dosimeter. The twin chamber radon dosimeter can record the values of radon, thoron and their decay products separately. Maximum and minimum indoor radon and thoron concentrations were evaluated and activity concentrations of radon and thoron daughters were estimated. The resulting dose rates due to radon, thoron and their decay products varied from 0.04 to 1.89 microSv/h. A detailed analysis of the distribution of radon, thoron and their decay products inside the house is also reported. The observed dose rates inside the houses of Kumaun Himalaya were found to be lower than the ICRP recommended value of 200 Bq/m3 and thus are within safe limits.  相似文献   

18.
中国经济增长与CO2排放演化探析   总被引:42,自引:6,他引:36  
随着全球能源消耗的持续增加,温室气体的排放和气候灾变日益受到各国政府的高度关注,有关区域经济发展与大气环境效应演变规律和态势的研究亦方兴未艾。本文旨在采用SPSS统计软件和Excel系统。以库兹涅茨环境曲线{EKC)及衍生曲线为依据,对中国CO2排放量与人均收入增长时序资料进行统计拟合得出中国经济发展与CO2排放的函数关系。研究表明,三次曲线方程较之标准型的环境库兹涅茨二次曲线方程更能映示中国数十年来经济发展与CO2排放变化之间的相依关系。这种似“N型”而非“倒U型”的演化特征。意昧着我国在同时推进经济发展和环境保护事业上仍处于过渡期,尚无法达到两者协同发展的阶段。为此,本文对我国耒案经济.社会的健康发展和CO2减排提出了系列应对的策略。  相似文献   

19.
Sweden introduced limits and gave recommendations for decreasing the indoor radon daughter concentrations in 1980. The resulting experiences are summarized. From 1979 to 1987, measurements were carried out by the local authorities in about 58 000 out of 3.9 million homes in Sweden, and 5300 homes were found to have levels exceeding the limit for existing houses, or 400 Bq/m3 of equilibrium equivalent concentration of radon (EER). This may be about 13% of the estimated 40 000 homes with levels exceeding 400 Bq/m3. Very high levels, up to 28 000 Bq/m3, have been found. According to the local authorities, in one third of the homes found with levels exceeding the limit (1921 homes) certain reconstruction and other measures have been taken in order to decrease the levels. In reality, measures have been carried out in more houses. The methods depend on the radon source. The average reductions found for respective methods are reported. The local authorities can require a check of the radon daughter concentrations in newly built houses when they suspect that the concentrations exceed the limit of 70 Bq/m3. In 11% of the measured homes built during 1981 to 1985, the levels were above the limit for newly built houses. In 1.4% of these houses, the limit for existing houses, 400 Bq/m3, had been exceeded. The strategy to decrease both the collective dose to the population and the individual dose is discussed.  相似文献   

20.
Enhanced levels of naturally occurring radioactive materials (NORM) are produced through various industrial operations and may lead to discharges to the marine environment. A recent study, called MARINA II, carried out for the European Commission considered discharges of radionuclides from the NORM industries to north European marine waters and their consequences. There are two main sources that were considered in the study. The use of phosphogypsum during the production of phosphoric acid by the fertiliser industry and the pumping of oil and gas from the continental shelf in the North Sea which produces large quantities of water contaminated with enhanced levels of naturally occurring radionuclides. Discharges of alpha emitting radionuclides from these two industries have contributed significantly to the total input of alpha emitters to north European waters over the period 1981-2000 (data were not available prior to 1981). Discharges due to the use of phosphogypsum have declined since the early 1990s and are now very low. Discharges from the oil and gas industries stabilised in the second half of the 1990s and are now the major contributor to alpha discharges to the region. As most European countries do not report discharges of radioactivity with the water produced during extraction, there is considerable uncertainty in the discharges used in the study. The impact of the discharges has been estimated both in terms of the effect on non-human biota and the radiological impact for people. In the 1980s the radiation dose rates to marine biota in the region around a phosphate plant on the north-west coast of England were as high due to the discharges from the phosphate plant as those near to the Sellafield reprocessing plant due to its discharges. In recent years the additional dose to marine biota in this region due to the past NORM discharges is of the same order of magnitude as the natural background. The collective dose rate was estimated to determine the radiological impact on people. The peak collective dose rate from the NORM industries occurred in 1984 and was just over 600 manSv y(-1). The collective dose rate fell with time as discharges from the phosphate industry reduced and was estimated as under 200 manSv y(-1) in 2000.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号