首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The effect of heat resistance and heat leakage on the optimal performance of finite time heat engines is investigated in this paperbased on a generalized heat transfer law q ∞ Δ(Tn). The analytical relation between optimal power output and efficiency for steady-state flow irreversible heat engines is derived. The analysis includes the optimal performance characteristics of several types of heat engines with different loss item and different heat transfer laws. A numerical example is provided for illustrating the power output versus efficiency characteristics. Results shown that the heat transfer law does affect the performance of these heat engines.  相似文献   

2.
Hydrogen-fed proton exchange membrane fuel cell (PEMFC) has to overcome high installation and operation cost before being adopted as a distributed power candidate. Cogeneration of power and heat is a good approach to increase hydrogen energy utilization rate. A PEMFC-based power and heat cogeneration system is proposed and established in the current study to investigate system’s technological and economical feasibility. This cogeneration of heat and power (CHP) system composes of a 2.5-kW fuel cell stack, hydrogen supply system, air supply system, water and heat management system, and heat recovery system. The control strategies to automate the system operation are realized by a programmable automation controller (PAC) system. Detailed measurement of the system is also constructed along with a web-based human–machine interface (HMI) platform to facilitate experiments and demonstration. Preliminary testing of the CHP system shows good performance of heat and power outputs. System’s electrical power conversion efficiency and thermal efficiency of the CHP system are measured at 38% and 35%, respectively. System combined efficiency therefore reached about 73%.  相似文献   

3.
In this paper, the power output of the cycle is taken as objective for performance optimization of an irreversible regenerated closed Brayton cycle coupled to constant-temperature thermal energy reservoirs in the viewpoint of finite time thermodynamics (FTT) or entropy generation minimization (EGM). The analytical formulae about the relations between power output and pressure ratio are derived with the heat resistance losses in the hot- and cold-side heat exchangers and the regenerator, the irreversible compression and expansion losses in the compressor and turbine, and the pressure drop loss in the piping. The maximum power output optimization is performed by searching the optimum heat conductance distribution corresponding to the optimum power output among the hot- and cold-side heat exchangers and the regenerator for the fixed total heat exchanger inventory. The influence of some design parameters, including the temperature ratio of the heat reservoirs, the total heat exchanger inventory, the efficiencies of the compressor and the turbine, and the pressure recovery coefficient, on the optimum heat conductance distribution and the maximum power output are provided. The power plant design with optimization leads to smaller size including the compressor, turbine, and the hot- and cold-side heat exchangers and the regenerator.  相似文献   

4.
Solar energy application in a large spectrum has the potential for high-efficiency energy conversion. Though, solar cells can only absorb photon energy of the solar spectrum near their band-gap energy, and the remaining energy will be converted into thermal energy. The use of the thermoelectric generator becomes a necessity for convert this thermal energy dissipated so as to increase efficiency conversion.

This paper analyses the feasibility of photovoltaic-thermoelectric hybrid system and reviews their performance in order to optimize harvested energy. Regarding the thermoelectric effect, a new method of the ambient energy harvesting is presented. This method combines thermoelectric generators and the effects of heat sensitive materials associated to photovoltaic cells in phase change for generating both energy day and night. Experimental measures have been conducted primarily in laboratory conditions for a greater understanding of hybridization phenomena under real conditions and to test the actual performance of devices made. Results show that the hybrid system can generate more power than the simple PV and TEG in environmental conditions. This hybrid technology will highlight the use of renewable energies in the service of the energy production.  相似文献   


5.
This paper aims at analyzing the feasibility of a waste heat recovery power generation plant based on parametric optimization and performance analysis using different organic Rankine cycle configurations and heat source temperature conditions with working fluid R-12, R-123, R-134a, and R-717. A parametric optimization of turbine inlet temperature(TIT) was performed to obtain the irreversibility rate, system efficiency, availability ratio, turbine work output, system mass flow rate, second-law efficiency, and turbine outlet quality, along the saturated vapor line and also on superheating at an inlet pressure of 2.50 MP in basic as well as regenerative organic Rankine cycle. The calculated results reveal that selection of a basic organic Rankine cycle using R-123 as working fluid gives the maximum system efficiency, turbine work output, second-law efficiency, availability ratio with minimum system irreversibility rate and system mass flow rate up to a TIT of 150°C and appears to be a choice system for generation of power by utilizing the flue gas waste heat of thermal power plants and above 150°C the regenerative superheat organic Rankine cycle configuration using R 123 as working fluid gives the same results.  相似文献   

6.
7.
The transcritical CO2 Rankine cycle with liquefied natural gas (LNG) as cold source is a promising power system to utilize mid- and low-temperature heat source. Most previous works focused on thermodynamic and thermoeconomic analysis or optimization for the system. In this article, an off-design performance analysis for the system is conducted. An off-design mathematical model for the system is established to examine the variation of system performance with the variations of heat source mass flow rate and temperature. A modified sliding pressure regulation control strategy, which regulates turbine inlet pressure to keep the temperature difference between heat source temperature and turbine inlet temperature constant, is applied to control the system when off-design conditions happen. The results show that when the mass flow rate or the temperature of heat source is less or lower than that of design condition, both the net power output of system and the system exergy efficiency decrease, whereas when they are more or higher than the values of design condition, the net power output of system increases but the system exergy efficiency still decreases. In addition, both CO2 turbine and NG turbine could almost keep the designed efficiency values under the applied control strategy.  相似文献   

8.
The study of the heat transfer enhancement for the recycling double-pass V-corrugated solar air heaters, which implement the external recycle of flowing air, was investigated experimentally and theoretically. The comparison among different designs of V-corrugated, baffled and fins attached, and flat-plate collectors was made to show the device performance improvement with various operating parameters under the same working dimensions. The recycling double-pass V-corrugated device developed here was proposed in aiming to strengthen the convective heat-transfer coefficient and enlarge the heat transfer area. The error analysis of experimental results deviate by 0.85–2.46% from the theoretical predictions with the fairly good agreement, and both results show that the device performance of the recycling double-pass V-corrugated operation is better than those of the other configurations under various recycle ratios and mass flow rates. The suitable selections were obtained for operating recycling double-pass V-corrugated devices while considering with an economic viewpoint by both the collector efficiency enhancement and the power consumption increment.  相似文献   

9.
New multilayer solar cells combine three innovations to produce a unique device structure which allows high efficiency cells to be designed on low quality material. The first innovation is the use of the multilayer structure itself, which provides the tolerance to low quality material. The second is the use of the well-proven buried contact technology. The third innovation is a simple technique for connecting cells in series which relies on having grooves of opposite polarity either overlapping or in close proximity to each other. These three innovations combine to produce a manufacturing approach with a small number of processing steps able to produce a product with a high energy conversion efficiency using low quality starting material. The unit of production is a large module of approximately 1 m2 in area rather than the smaller 100 cm2 cells which are the present commercial norm .  相似文献   

10.
In this paper, an isolated ac module with pseudo dc-link and galvanic isolation is proposed for photovoltaic energy conversion. The studied grid-tie ac module can individually extract the maximum solar power from each photovoltaic panel and transfer to ac utility system. It consists of an interleaved active-clamping single-ended primary-inductive circuit (SEPIC) with a secondary voltage doubler, a full-bridge polarity selector operating under line frequency to achieve high efficiency. For the studied topology, key features such as reduced input current ripple, zero-voltage switching (ZVS) of primary switches, low reverse-recovery current of the output diodes, and lower switch voltage stress are obtained. Also, to reduce input current ripple, an interleaved control strategy is adopted. A simple control strategy is proposed to generate a rectified sinusoidal waveform voltage at the pseudo dc-link capacitors and achieve the high maximum power point tracking (MPPT) accuracy. The operation principles and design considerations of the studied ac module are analyzed and discussed. A prototype with 25–60 V dc input, 110 V/60 Hz ac output and 150 W power rating has been constructed for verifying the feasibility of the proposed ac module.  相似文献   

11.
When integrating a post-combustion CO2 capture process and CO2 compression into a steam power plant, the three interface quantities heat, electricity and cooling duty must be satisfied by the power plant, leading to a loss in net efficiency. The heat duty shows to be the largest contributor to the overall net efficiency penalty of the power plant. Additional energy penalty results from the cooling and electric power duty of the capture and compression units.In this work, the dependency of the energy penalty on the quantity and quality of the heat duty is analyzed and quantified for a state-of-the-art hard coal fired power plant. Furthermore, the energy penalty attributed to the additional cooling and power duty is quantified. As a result correlations are provided which enable to predict the impact of the heat, cooling and electricity duty of post-combustion CO2 capture processes on the net output of a steam power plant in a holistic approach.  相似文献   

12.
In most industrialized countries, environmental standards exist which prescribe the maximum allowable man-made increase in water temperature of a river. Together with flowrate and weather conditions, these standards determine the rate at which waste heat may be discharged into a river at any moment. Power generating stations with variable cooling systems can adjust their heat discharge into the river in compliance with environmental standards and by doing so exert an influence on power generation capacity. In this paper, a scheme is developed that allows a chain of power stations discharging into the same river to operate their cooling systems such that the output of total electricity is maximized and water temperature standards are accomodated. The optimum balance between stations is determined through dynamic programming. From the results of a simulation model using historical data, simple decision rules for day-to-day operation are abstracted. These rules are based solely on the river flow rates at each power station.  相似文献   

13.
This article presents a new thermoelectric generator power analysis system (TEG-PAS) for the examination of all parameters of the thermoelectric generators (TEGs) operated by geothermal or any liquid heat. As a sample application, the developed TEG-PAS has been tried on a TEG of 100 W. During electrical energy generation, the values of the electrical, the thermo-electrical and the thermal variables of the TEG have been transmitted to the TEG-PAS by the employed sensors. Thus, the using of several devices simultaneously has been eliminated while the power performance analyses are being carried out.  相似文献   

14.
This paper presents the performance of the solid-oxide fuel cell/gas turbine hybrid power generation system with heat recovery waste unit based on the energy and exergy analyses. The effect of air inlet temperature and air/fuel ratio on exergy destruction and network output is determined. For the numerical calculations, air inlet temperature and air fuel ratio are increased from 273 to 373 K and from 40 to 60, respectively. The results of the numerical calculations bring out that total exergy destruction quantity increases with the increase of air inlet temperature and air/fuel ratio. Furthermore, the maximum system overall first and second law efficiencies are obtained in the cases of air inlet temperature and air/fuel ratio equal to 273 K and 60, respectively, and these values are 62.09% and 54.91%.  相似文献   

15.
The condenser is a piece of equipment used to effectively transfer heat from water to the environment. The fin and tube condenser is the most commonly used in commercial applications. The improved performance of heat transfer in the fin and tube condenser is a significant area of study all over the world because optimizing the efficiency of heat transfer in the condenser will contribute to enhancing the effectiveness of system performance. The vapor deposition, plasma spray, and thermal spray techniques are being used, and it is determined that a heat transfer enhancing coating improves condenser performance. This review discusses the nanomaterial coating over the fin and tube condenser in detail. The various nanomaterial coatings with various propositions and coating methods had been discussed with the evidence of previous researchers. At a 50-degree inclination angle on the condensate plate, the condensate over the coating surface increases by more than 30%. The thermal properties of the working fluid are improved over the condenser, and the overall effectiveness of the condenser is increased by approximately 40% over the non-coated condenser. A 1% volumetric concentration of Nanoparticles in the coated material achieves a maximum efficiency increase of 78.7%.  相似文献   

16.
为探讨废水中硫酸盐对微生物燃料电池(MFC)产电效能的影响,采用单室空气阴极MFC反应器处理模拟硫酸盐废水,并对硫酸盐的电子分流过程进行了监测。结果表明,在一定范围内,提高硫酸盐浓度能使MFC的稳定电压上升,电池持续时间延长,MFC输出功率增大。随着进水硫酸盐浓度提高,微生物产生的电子总量中,硫酸盐还原捕获的电子和通过外电路的电子所占的比例均下降,分别由12.54%和31.45%下降至7_32%和8.49%。研究表明,较低浓度硫酸盐能够提高MFC的电能输出功率,但由于硫酸盐的还原将消耗掉大量电子,进而降低MFC的库伦效率。  相似文献   

17.
Experiments are described to investigate the thermal performance of a discharging heat exchanger for a small storage tank filled with oil. Experimental results are presented in terms of the discharging energy rates (power) and the discharging exergy rates for low (~4 ml/s) and high discharging flow rates (~8 ml/s). Water heating energy rates, which are respectively maximized at approximately 600 W and 1200 W at low and high flow-rate discharging, are found to be higher than the discharging energy rates, which are respectively maximized at 450 W and 900 W. These results indicate that the energy rates do not accurately evaluate the thermal performance of the discharging heat exchanger since the energy heating rate of the water is greater than that for the oil that heats it, which is thermodynamically inconsistent. The energy rates should thus be used with caution when the thermal performance of the heat exchanger is evaluated. Water heating exergy rates, which are respectively maximized at approximately 45 W and 130 W at low and high flow-rate discharging, are generally smaller than the discharging exergy rates, which are respectively maximized at 65 W and 170 W. Exergy rate results are thus more consistent in the physical process of water heating, and an exergy factor is suggested as a proper measure for evaluating the performance of the discharging heat exchanger. The maximum value of the exergy factor is found to increase from 0.15 at low flow rates to a maximum value of approximately 0.19 at high flow rates. This implies that to extract more energy from a storage tank to a discharging heat exchanger, the flow rate has to be high, which is consistent with the physical process of heating water faster to higher temperatures. The exergy factor can thus be used as a design parameter for discharging heat exchangers.  相似文献   

18.
With the drastic decrease in fossil resources and rapid deterioration of the global environment, the utilization of geothermal resources has been strongly advocated. The combination of heat, power, and cold utility generation is commonly used to increase the utilization efficiency of geothermal resources. In this study, an integrated cascade utilization system of waste geothermal water (ICUWGW) from a flash geothermal power plant in China is established to increase the utilization efficiency of geothermal water. The waste geothermal water leaving the power plant is proposed for further use in cascade for two-stage LiBr/H2O absorption cooling, agricultural product drying, and residential bathing. Twelve candidate temperature schemes showing different inlet and outlet temperatures of every subsystem are proposed for the ICUWGW. Several criteria are selected for the evaluation and screening of the candidate schemes. Grey relational analysis incorporating analytic hierarchy process is conducted to screen the optimal temperature scheme for the ICUWGW to meet the comprehensive criteria of thermodynamics and economics. Results show that the optimal scheme features significant improvement in energy efficiency, exergy efficiency, and equivalent electricity generation efficiency compared with those of the current geothermal power plant. The investment payback time of the additional subsystems for cooling, drying, and bathing is 1.85 years. Exergy analysis is also conducted to determine the further optimization potential of the optimal ICUWGW. Sensitivity analysis of electricity price on the performance of the optimal ICUWGW is also performed.  相似文献   

19.
In this research, desert sand is used as the sensible heat storage medium, which exchanges heat with air in the downcomer to realize heat storage and heat release. The desert sand distribution uniformity has a significant impact on the heat exchange performance and efficiency between desert sand and air for the process of convection in the downcomer. Given the superiority of sensible heat storage in convective heat transfer between desert sand and air, distributors with cylinder or conical bore solid particles and homogeneity performance testing device are designed and manufactured on the basis of convection system equipped with solid particle–air downcomer. Then, the convection experiment between solid sand and air is researched. The greater the desert sand flow rate and higher the volume density, the larger the variance of regional mass flow rate and the worse the homogeneity performance. For the cylinder bore distributor, the smaller the sand particle size is, the greater affected the sand groups can be. The sand homogeneity performance is preferable with the two particle size ranges: 0.18-0.25 mm and 0.15-0.18 mm. The total sand flow rate decreases, but the uniformity improves with the increase of the air flow velocity, and the best distribution performance is achieved at an air velocity of 0.6 m/s. However, the distribution performance declines with the air flow velocity persistently increasing because the sand groups are pushed to one pipe side close to the wall. The sand groups deflect seriously with the air flow velocity increasing.  相似文献   

20.
The device performance of double-pass V-corrugated solar air heaters with external recycle was investigated experimentally and theoretically. The comparison between V-corrugated and flat-plate collectors was made to show the thermal efficiency improvement with various operating parameters. The results show that the collector efficiency improvement of the recycling double-pass V-corrugated operation is much higher than those of the other configurations under various recycle ratios and mass flow rates. However, there exists the penalty on the power consumption increment due to implementing V-corrugated channel into the solar air heaters, an economic consideration on both the heat-transfer efficiency enhancement and power consumption increment for the double-pass V-corrugated device was also delineated. The experimental setup was carried out to validate the theoretical predictions, and the fairly good agreement between both results was achieved with the error analysis of 0.48-1.83%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号